Development of Detailed Korean Adult Eye Model for Lens Dose Calculation

  • Han, Haegin (Department of Nuclear Engineering, Hanyang University) ;
  • Zhang, Xujia (Department of Nuclear Engineering, Hanyang University) ;
  • Yeom, Yeon Soo (Division of Cancer Epidemiology and Genetics, National Cancer Institute, National Institute of Health) ;
  • Choi, Chansoo (Department of Nuclear Engineering, Hanyang University) ;
  • Nguyen, Thang Tat (School of Nuclear Engineering and Environmental Physics, Hanoi University of Science and Technology) ;
  • Shin, Bangho (Department of Nuclear Engineering, Hanyang University) ;
  • Ha, Sangseok (Department of Nuclear Engineering, Hanyang University) ;
  • Moon, Sungho (Department of Nuclear Engineering, Hanyang University) ;
  • Kim, Chan Hyeong (Department of Nuclear Engineering, Hanyang University)
  • 투고 : 2020.02.19
  • 심사 : 2020.03.17
  • 발행 : 2020.03.31

초록

Background: Recently, the International Commission on Radiological Protection (ICRP) lowered the dose limit for the eye lens from 150 mSv to 20 mSv, highlighting the importance of accurate lens dose estimation. The ICRP reference computational phantoms used for lens dose calculation are mostly based on the data of Caucasian population, and thus might be inappropriate for Korean population. Materials and Methods: In the present study, a detailed Korean eye model was constructed by determining nine ocular dimensions using the data of Korean subjects. The developed eye model was then incorporated into the adult male and female mesh-type reference Korean phantoms (MRKPs), which were then used to calculate lens doses for photons and electrons in idealized irradiation geometries. The calculated lens doses were finally compared with those calculated with the ICRP mesh-type reference computational phantoms (MRCPs) to observe the effect of ethnic difference on lens dose. Results and Discussion: The lens doses calculated with the MRKPs and the MRCPs were not much different for photons for the entire energy range considered in the present study. For electrons, the differences were generally small, but exceptionally large differences were found at a specific energy range (0.5-1 MeV), the maximum differences being about 10 times at 0.6 MeV in the anteroposterior geometry; the differences are mainly due to the difference in the depth of the lens between the MRCPs and the MRKPs. Conclusion: The MRCPs are generally considered acceptable for lens dose calculations for Korean population, except for the electrons at the energy range of 0.5-1 MeV for which it is suggested to use the MRKPs incorporating the Korean eye model developed in the present study.

키워드

참고문헌

  1. Stewart FA, Akleyev AV, Hauer-Jensen M, Hendry JH, Kleiman NJ, Macvittie TJ, et al. ICRP Publication 118. ICRP statement on tissue reactions and early and late effects of radiation in normal tissues and organs: threshold doses for tissue reactions in a radiation protection context. Ann ICRP. 2012;41:1-322.
  2. Petoussi-Henss N, Bolch WE, Eckerman KF, Endo A, Hertel N, Hunt J, et al. ICRP Publication 116. Conversion coefficients for radiological protection quantities for external radiation exposures. Ann ICRP. 2010;40:1-257.
  3. Menzel HG, Clement C, DeLuca P. ICRP Publication 110. Realistic reference phantoms: an ICRP/ICRU joint effort: a report of adult reference computational phantoms. Ann ICRP. 2009;39: 1-164.
  4. Behrens R, Dietze G, Zankl M. Dose conversion coefficients for electron exposure of the human eye lens. Phys Med Biol. 2009; 54:4069-4087. https://doi.org/10.1088/0031-9155/54/13/008
  5. Behrens R, Dietze G. Dose conversion coefficients for photon exposure of the human eye lens. Phys Med Biol. 2011;56:415-437. https://doi.org/10.1088/0031-9155/56/2/009
  6. Kim CH, Yeom YS, Nguyen TT, Han MC, Choi C, Lee H, et al. New mesh-type phantoms and their dosimetric applications, including emergencies. Ann ICRP. 2018;47:45-62. https://doi.org/10.1177/0146645318756231
  7. Nguyen TT, Yeom YS, Kim HS, Wang ZJ, Han MC, Kim CH, et al. Incorporation of detailed eye model into polygon-mesh versions of ICRP-110 reference phantoms. Phys Med Biol. 2015;60:8695-8707. https://doi.org/10.1088/0031-9155/60/22/8695
  8. Yeom YS, Choi C, Han H, Lee H, Shin B, Nguyen TT, et al. Dose coefficients of mesh-type ICRP reference computational phantoms for idealized external exposures of photons and electrons. Nucl Eng Technol. 2019;51:843-852. https://doi.org/10.1016/j.net.2018.12.006
  9. Yeom YS, Choi C, Han H, Shin B, Nguyen TT, Han MC, et al. Dose coefficients of mesh-type ICRP reference computational phantoms for external exposures of neutrons, protons, and helium ions. Nucl Eng Technol. 2019 Dec 25 [Epub]. https://doi.org/10.1016/j.net.2019.12.020.
  10. International Atomic Energy Agency. Compilation of anatomical, physiological and metabolic characteristics for a Reference Asian Man. Vienna, Austria: International Atomic Energy Agency; 1998.
  11. Choi C, Nguyen TT, Yeom YS, Lee H, Han H, Shin B, et al. Meshtype reference Korean phantoms (MRKPs) for adult male and female for use in radiation protection dosimetry. Phys Med Biol. 2019;64:085020. https://doi.org/10.1088/1361-6560/ab0b59
  12. Choi C, Yeom YS, Nguyen TT, Lee H, Han H, Shin B, et al. Korean anatomical reference data for adults for use in radiological protection. J Korean Phys Soc. 2018;72:183-191. https://doi.org/10.3938/jkps.72.183
  13. Charles MW, Brown N. Dimensions of the human eye relevant to radiation protection. Phys Med Biol. 1975;20:202-218. https://doi.org/10.1088/0031-9155/20/2/002
  14. Lee DW, Kim JM, Choi CY, Shin D, Park KH, Cho JG. Age-related changes of ocular parameters in Korean subjects. Clin Ophthalmol. 2010;4:725-730.
  15. Park SH, Park KH, Kim JM, Choi CY. Relation between axial length and ocular parameters. Ophthalmologica. 2010;224:188-193. https://doi.org/10.1159/000252982
  16. Lim KJ, Hyung SM, Youn DH. Ocular dimensions with aging in normal eyes. Korean J Ophthalmol. 1992;6:19-31. https://doi.org/10.3341/kjo.1992.6.1.19
  17. Kim HS, Mah KC, Kwon YS, Kim BH, Lee CH. Biometric measurements of anterior eye segment used by the Nidek EAS-1000. Korean J Vis Sci. 2000;2:77-85.
  18. Basic anatomical and physiological data for use in radiological protection: reference values. A report of age- and gender-related differences in the anatomical and physiological characteristics of reference individuals. ICRP Publication 89. Ann ICRP. 2002;32:5-265. https://doi.org/10.1016/S0146-6453(02)00021-0
  19. Olsen T. Calculation of intraocular lens power: a review. Acta Ophthalmol Scand. 2007;85:472-485. https://doi.org/10.1111/j.1600-0420.2007.00879.x
  20. Zhu H, Qiu R, Wu Z, Ren L, Li C, Zhang H, et al. Establishment of detailed eye model of adult Chinese male and dose conversion coefficients calculation under neutron exposure. Radiat Prot Dosimetry. 2017;177:295-301. https://doi.org/10.1093/rpd/ncx044
  21. Recommendations of the International Commission on Radiological Protection; revised December 1, 1954. Br J Radiol. 1955; Suppl 6:1-92.
  22. Si H. TetGen, a Delaunay-based quality tetrahedral mesh generator. ACM Trans Math Softw. 2015;41:1-36. https://doi.org/10.1145/2629697
  23. Allison J, Amako K, Apostolakis J, Arce P, Asai M, Aso T, et al. Recent developments in Geant4. Nucl Instrum Methods Phys Res A. 2016;835:186-225. https://doi.org/10.1016/j.nima.2016.06.125

피인용 문헌

  1. Report of IRPA task group on issues and actions taken in response to the change in eye lens dose limit vol.40, pp.4, 2020, https://doi.org/10.1088/1361-6498/abb5ec
  2. Development of detailed pediatric eye models for lens dose calculations vol.41, pp.2, 2020, https://doi.org/10.1088/1361-6498/abfa32