DOI QR코드

DOI QR Code

Surgical Reconstruction Using a Flanged Mesh Cage without Plating for Cervical Spondylotic Myelopathy and a Symptomatic Ossified Posterior Longitudinal Ligament

  • Kang, Jung Hoon (Department of Neurosurgery, Soonchunhyang University Bucheon Hospital, Soonchunhyang University College of Medicine) ;
  • Im, Soo-Bin (Department of Neurosurgery, Soonchunhyang University Bucheon Hospital, Soonchunhyang University College of Medicine) ;
  • Yang, Sang-Mi (Department of Neurosurgery, Soonchunhyang University Bucheon Hospital, Soonchunhyang University College of Medicine) ;
  • Chung, Moonyoung (Department of Neurosurgery, Soonchunhyang University Bucheon Hospital, Soonchunhyang University College of Medicine) ;
  • Jeong, Je Hoon (Department of Neurosurgery, Soonchunhyang University Bucheon Hospital, Soonchunhyang University College of Medicine) ;
  • Kim, Bum-Tae (Department of Neurosurgery, Soonchunhyang University Bucheon Hospital, Soonchunhyang University College of Medicine) ;
  • Hwang, Sun-Chul (Department of Neurosurgery, Soonchunhyang University Bucheon Hospital, Soonchunhyang University College of Medicine) ;
  • Shin, Dong-Seong (Department of Neurosurgery, Soonchunhyang University Bucheon Hospital, Soonchunhyang University College of Medicine) ;
  • Park, Jong-Hyun (Department of Neurosurgery, Soonchunhyang University Bucheon Hospital, Soonchunhyang University College of Medicine)
  • 투고 : 2019.02.28
  • 심사 : 2019.04.09
  • 발행 : 2019.11.01

초록

Objective : We introduce innovative method of cervical column reconstruction and performed the reconstruction with a flanged titanium mesh cage (TMC) instead of a plate after anterior corpectomy for cervical spondylotic myelopathy (CSM) and an ossified posterior longitudinal ligament (OPLL). Methods : Fifty patients with CSM or OPLL who underwent anterior cervical reconstruction with a flanged TMC were investigated retrospectively. Odom's criteria were used to assess the clinical outcomes. The radiographic evaluation included TMC subsidence, fusion status, and interbody height. Thirty-eight patients underwent single-level and 12 patients underwent two-level corpectomy with a mean follow-up period of 16.8 months. Results : In all, 19 patients (38%) had excellent outcomes and 25 patients (50%) had good outcomes. Two patients (4%) in whom C5 palsy occurred were categorized as poor. The fusion rate at the last follow-up was 98%, and the severe subsidence rate was 34%. No differences in subsidence were observed among Odom's criteria or between the single-level and two-level corpectomy groups. Conclusion : The satisfactory outcomes in this study indicate that the flanged TMC is an effective graft for cervical reconstruction.

키워드

참고문헌

  1. Al-Mashani AMM, Lad S, Salhotra N, Ali A, Khan RM, Kaul N : Comparison of the efficacy of multi level cervical discectomy and corpectomy using titanium cage with and without anterior cervical plate. Am J Med Case Rep 3 : 406-409, 2015
  2. Benzel EC, Francis TB : Spine surgery: techniques, complication avoidance and management. Philadelphia : Elsevier/Saunders, 2012
  3. Bydon M, Macki M, Kaloostian P, Sciubba DM, Wolinsky JP, Gokaslan ZL, et al. : Incidence and prognostic factors of c5 palsy: a clinical study of 1001 cases and review of the literature. Neurosurgery 74 : 595-604; discussion 604-605, 2014 https://doi.org/10.1227/NEU.0000000000000322
  4. Chen Y, Chen D, Guo Y, Wang X, Lu X, He Z, et al. : Subsidence of titanium mesh cage: a study based on 300 cases. J Spinal Disord Tech 21 : 489-492, 2008 https://doi.org/10.1097/BSD.0b013e318158de22
  5. Chen Y, Chen D, Wang X, Lu X, Guo Y, He Z, et al. : Anterior corpectomy and fusion for severe ossification of posterior longitudinal ligament in the cervical spine. Int Orthop 33 : 477-482, 2009 https://doi.org/10.1007/s00264-008-0542-y
  6. Epstein NE : Reoperation rates for acute graft extrusion and pseudarthrosis after one-level anterior corpectomy and fusion with and without plate instrumentation: etiology and corrective management. Surg Neurol 56 : 73-80, 2001 https://doi.org/10.1016/S0090-3019(01)00523-7
  7. Gao R, Yang L, Chen H, Liu Y, Liang L, Yuan W : Long term results of anterior corpectomy and fusion for cervical spondylotic myelopathy. PLoS One 7 : e34811, 2012 https://doi.org/10.1371/journal.pone.0034811
  8. Hasegawa K, Abe M, Washio T, Hara T : An experimental study on the interface strength between titanium mesh cage and vertebra in reference to vertebral bone mineral density. Spine 26 : 957-963, 2001 https://doi.org/10.1097/00007632-200104150-00022
  9. Hussain M, Nassr A, Natarajan RN, An HS, Andersson GB : Biomechanical effects of anterior, posterior, and combined anterior-posterior instrumentation techniques on the stability of a multilevel cervical corpectomy construct: a finite element model analysis. Spine J 11 : 324-330, 2011 https://doi.org/10.1016/j.spinee.2011.02.008
  10. Jang JW, Lee JK, Lee JH, Hur H, Kim TW, Kim SH : Effect of posterior subsidence on cervical alignment after anterior cervical corpectomy and reconstruction using titanium mesh cages in degenerative cervical disease. J Clin Neurosci 21 : 1779-1785, 2014 https://doi.org/10.1016/j.jocn.2014.02.016
  11. Karikari IO, Jain D, Owens TR, Gottfried O, Hodges TR, Nimjee SM, et al. : Impact of subsidence on clinical outcomes and radiographic fusion rates in anterior cervical discectomy and fusion: a systematic review. J Spinal Disord Tech 27 : 1-10, 2014 https://doi.org/10.1097/BSD.0b013e31825bd26d
  12. Li J, Zheng Q, Guo X, Zeng X, Zou Z, Liu Y, et al. : Anterior surgical options for the treatment of cervical spondylotic myelopathy in a long-term follow-up study. Arch Orthop Trauma Surg 133 : 745-751, 2013 https://doi.org/10.1007/s00402-013-1719-4
  13. Mazur M, Jost GF, Schmidt MH, Bisson EF : Management of cerebrospinal fluid leaks after anterior decompression for ossification of the posterior longitudinal ligament: a review of the literature. Neurosurg Focus 30 : E13, 2011
  14. Nakase H, Park YS, Kimura H, Sakaki T, Morimoto T : Complications and long-term follow-up results in titanium mesh cage reconstruction after cervical corpectomy. J Spinal Disord Tech 19 : 353-357, 2006 https://doi.org/10.1097/01.bsd.0000210113.09521.aa
  15. Ning X, Wen Y, Xiao-Jian Y, Bin N, De-Yu C, Jian-Ru X, et al. : Anterior cervical locking plate-related complications; prevention and treatment recommendations. Int Orthop 32 : 649-655, 2008 https://doi.org/10.1007/s00264-007-0369-y
  16. Oshina M, Oshima Y, Tanaka S, Riew KD : Radiological fusion criteria of postoperative anterior cervical discectomy and fusion: a systematic review. Global Spine J 8 : 739-750, 2018 https://doi.org/10.1177/2192568218755141
  17. Panchal RR, Kim KD, Krel MA, Lopez J, Shahlaie K, Bobinski M : Using titanium mesh cage and anterior cervical plate for cervical corpectomies. J Spine Neurosurg 2 : 4, 2013
  18. Tasiou A, Giannis T, Brotis AG, Siasios I, Georgiadis I, Gatos H, et al. : Anterior cervical spine surgery-associated complications in a retrospective case-control study. J Spine Surg 3 : 444-459, 2017 https://doi.org/10.21037/jss.2017.08.03
  19. Thompson SE, Smith ZA, Hsu WK, Nassr A, Mroz TE, Fish DE, et al. : C5 palsy after cervical spine surgery: a multicenter retrospective review of 59 cases. Global Spine J 7 : 64S-70S, 2017 https://doi.org/10.1177/2192568216688189
  20. Yan D, Wang Z, Deng S, Li J, Soo C : Anterior corpectomy and reconstruction with titanium mesh cage and dynamic cervical plate for cervical spondylotic myelopathy in elderly osteoporosis patients. Arch Orthop Trauma Surg 131 : 1369-1374, 2011. https://doi.org/10.1007/s00402-011-1317-2
  21. Yang X, Chen Q, Liu L, Song Y, Kong Q, Zeng J, et al. : Comparison of anterior cervical fusion by titanium mesh cage versus nano-hydroxyapatite/ polyamide cage following single-level corpectomy. Int Orthop 37 : 2421-2427, 2013 https://doi.org/10.1007/s00264-013-2101-4
  22. Zeng J, Duan Y, Yang Y, Wang B, Hong Y, Lou J, et al. : Anterior corpectomy and reconstruction using dynamic cervical plate and titanium mesh cage for cervical spondylotic myelopathy : a minimum 5-year follow-up study. Medicine (Baltimore) 97 : e9724, 2018 https://doi.org/10.1097/MD.0000000000009724
  23. Zhang Y, Deng X, Jiang D, Luo X, Tang K, Zhao Z, et al. : Long-term results of anterior cervical corpectomy and fusion with nano-hydroxyapatite/ polyamide 66 strut for cervical spondylotic myelopathy. Sci Rep 6 : 26751, 2016 https://doi.org/10.1038/srep26751