참고문헌
- Abali, E. and Uckan, E. (2010), "Parametric analysis of liquid storage tanks base isolated by curved surface sliding bearings", Soil Dyn. Earthq. Eng., 30, 21-31. https://doi.org/10.1016/j.soildyn.2009.08.001
- Angelis, M.D., Giannini, R. and Paolacci, F. (2010), "Experimental investigation on the seismic response of a steel liquid storage tank equipped with floating roof by shaking table tests", Earthq. Eng. Struct. Dyn., 39(4), 377-396. https://doi.org/10.1002/eqe.945
- Chakraborty, S., Roy, K. and Ray-Chaudhuri, S. (2016), "Design of re-centering spring for flat sliding base isolation system: Theory and a numerical study", Eng. Struct., 126, 66-77. https://doi.org/10.1016/j.engstruct.2016.07.049
- Chalhoub, M.S. and Kelly, J.M. (1990), "Shake table test of cylindrical water tanks in base-isolated structures", J. Eng. Mech., ASCE, 116(7), 1451-1472. https://doi.org/10.1061/(ASCE)0733-9399(1990)116:7(1451)
- Cheng, X.S., Cao, L.L. and Zhu, H.Y. (2015), "Liquid-solid interaction seismic response of an isolated overground rectangular reinforced-concrete liquid-storage structure", J. Asian Arch. Build. Eng., 14, 175-180. https://doi.org/10.3130/jaabe.14.175
- Cheng, X.S., Jing, W. and Gong, L.J. (2017), "Simplified model and energy dissipation characteristics of a rectangular liquid-storage structure controlled with sliding base isolation and displacement-limiting devices", J. Perform. Constr. Facil., ASCE, 31(5), 1-11.
- Fan, J. and Tang, J.X. (2001), "Dynamic characteristics and earthquake response analysis of structures supported on slidelimited friction base isolation system", J. Build. Struct., 22(1), 20-25.
- Gao, L., Guo, E.D., Wang, X.J. et al. (2012), "Earthquake damage analysis of pools in water supply system", J. Nat. Disast., 21(5), 120-126.
- GB50011-2010 (2016), Code for Seismic Design of Buildings, China Architecture & Building Press, Beijing.
- Jaiswal, O.R., Rai, D.C. and Jain, S.K. (2007), "Review of seismic codes on liquid-containing tanks", Earthq. Spectra, 23(1), 239-260. https://doi.org/10.1193/1.2428341
- Jalali, A., Cardone, D. and Narjabadifam, P. (2011), "Smart restorable sliding base isolation system", Bull. Earthq. Eng., 9(2), 657-673. https://doi.org/10.1007/s10518-010-9213-7
- Kim, N.S. and Lee, D.G. (1995), "Pseudo-dynamic test for evaluation of seismic performance of base isolated liquid storage tanks", Eng. Struct., 17(3), 198-208. https://doi.org/10.1016/0141-0296(95)00076-J
- Li, J., Chen, H.M., Chen, J.B. et al. (2006), "An experimental study on prestressed egg-shape digesters", China Civil Eng. J., 39(5), 35-42
- Li, X.Y. and Xue, S.D. (2011), "Model and design method of a sliding bearing combimed with springs for horizontal seismic isolation", J. Beijing Univ. Technol., 37(11), 1650-1654.
- Li, Z.J. and Deng, Z.C. (2008), "Fuzzy sliding mode control of sliding-isolated buildings", J. Vib. Shock, 27(9), 111-115.
- Lu, L.Y., Lin, C.C. and Lin, G.L. (2013), "Experimental evaluation of supplemental viscous damping for a sliding isolation system under pulse-like base excitations", J. Sound Vib., 332(8), 1982-1999. https://doi.org/10.1016/j.jsv.2012.12.008
- Madden, G.J., Symans, M.D. and Wongprasert, N. (2002), "Experimental verification of seismic response of building frame with adaptive sliding base-isolation system", J. Struct. Eng., 128(8), 1037-1045. https://doi.org/10.1061/(ASCE)0733-9445(2002)128:8(1037)
- Malhotra, P.K. (1997), "New method for seismic isolation of liquid storage tanks", Earthq. Eng. Struct. Dyn., 26(8), 839-847. https://doi.org/10.1002/(SICI)1096-9845(199708)26:8<839::AID-EQE679>3.0.CO;2-Y
- Panchal, V.R. and Jangid, R.S. (2011), "Seismic response of liquid storage steel tanks with variable frequency pendulum isolator", KSCE J. Civil Eng., 15(6), 1041-1055. https://doi.org/10.1007/s12205-011-0945-y
- Rai, D.C. (2002), "Seismic retrofitting of R/C shaft support of elevated tanks", Earthq. Spectra, 18(4), 745-760. https://doi.org/10.1193/1.1516753
- Saha, S.K., Matsagar, V.A. and Jain, A.K. (2016), "Seismic fragility of base-isolated water storage tanks under non-stationary earthquakes", Bull. Earthq. Eng., 14(4), 1153-1175. https://doi.org/10.1007/s10518-016-9874-y
- Saha, S.K., Sepahvand, K., Matsagar, V.A. et al. (2013), "Stochastic analysis of base-isolated liquid storage tanks with uncertain isolator parameters under random excitation", Eng. Struct., 57(4), 465-474. https://doi.org/10.1016/j.engstruct.2013.09.037
- Shekari, M.R. and Khaji, N. (2010), "Ahmadi M T. On the seismic behavior of cylindrical base-isolated liquid storage tanks excited by long-period ground motions", Soil Dyn. Earthq. Eng., 30(10), 968-980. https://doi.org/10.1016/j.soildyn.2010.04.008
- Yang, Y., Sun, J.G., Zou, D.L. et al. (2011), "Research on the foundation slipping-isolation of vertical storage tanks", Oil-Gasfield Surf. Eng., 30(2), 30-32.
- Zhang, R.F., Weng, D.G. and Ge, Q.Z. (2014), "Shaking table experiment on a steel storage tank with multiple friction pendulum bearings", Struct. Eng. Mech., 52(5), 875-887. https://doi.org/10.12989/sem.2014.52.5.875
- Zhang, R.F., Weng, D.G. and Ren, X.S. (2011), "Seismic analysis of a LNG storage tank isolated by a multiple friction pendulum system", Earthq. Eng. Eng. Vib., 10(2), 253-262. https://doi.org/10.1007/s11803-011-0063-3
- Zou, S., Ikago, K., Inoue, N. et al. (2016), "Design optimization of friction damper with coupling mechanism for seismic response of base isolated structure", J. Vib. Eng., 29(2), 201-206.
피인용 문헌
- Shock absorption of concrete liquid storage tank with different kinds of isolation measures vol.18, pp.4, 2018, https://doi.org/10.12989/eas.2020.18.4.467