Examination of the Disposal Procedure for Nuclear Medical Test with 125I through In-vitro Test

  • Received : 2017.11.27
  • Accepted : 2018.01.16
  • Published : 2018.03.31

Abstract

Nuclear medicine in vitro tests are performed on an average of 14 million cases annually in Korea. $^{125}I$, a nuclear species mainly used for in vitro tests, was estimated to have a longer shelf-life than other nuclides because the half-life was longer than other nuclides. Most institutions have judged that the radioactive waste will be about 1/1000 of the original radioactivity when it was stored for a period corresponding to 10 times the half-life of the radioactive waste, and thus the disposal will be satisfied. However, as the amount of radioactive materials remaining in the waste generated by the mechanization and modernization of the inspection method was reduced, it is necessary to reasonably infer the storage period. As a result, the storage period can be calculated reasonably. Waste generated from this test include tubes, beads, vials, tips, and other miscellaneous flammable substances(tissue paper, gauze, paper, etc.). To estimate the reasonable storage of these wastes, the amount of residual radioactive material was measured using a DREAM GAMMA-10 counter, and the period was calculated based on this value. For the purpose of this study, all tubes and beads used for the tests during the year 2016 were measured at a medical checkup hospital in Seoul. A total of 398,879 testing tubes, with 4,155 tubes per box, with a minimum number of 2,792 and a maximum number of 4,374, were used. As a results indicate, the self-disposable period of the tube was measured as 14 days, the beads as 234 days, plastic vials as 177 days, and gauze as 365 days. It was deduced that there is no economical gain because it is not necessary to store for 1 year and 6 months, 10 times the half-life period of $^{125}I$, which was a conservative calculation method.

Keywords

Acknowledgement

Supported by : Korea Atomic Energy Research Institute (KAERI)

References

  1. Dean L. 2005. Blood Groups and Red Cell Antigens, pp. 97-98. In: Blood transfusions and the immune system, National Center for Biotechnology Information (NCBI), National Library of Medicine, National Institutes of Health, Bethesda, MD 20892-6510.
  2. Kim CB. 2014a. Measurement and Estimation for the Clearance of Radioactive Waste Contaminated with Radioisotopes for Medical Application. Dongshin University. Department of Radiological Physics, School of Public Health, School of Public Health, pp. 14.
  3. Kim CB. 2014b. Measurement and Estimation for the Clearance of Radioactive Waste Contaminated with Radioisotopes for Medical Application. Dongshin University. Department of Radiological Physics, School of Public Health, School of Public Health, pp. 15-18.
  4. Korea Radioisotope Association. 2013. Statistics on the Radiation Practices in Korea, 39p.
  5. Lee KJ, Sul JH, Lee IW and Park YJ. 2017. Discussion about the Self Disposal Guideline of Medical Radioactive Waste. J. Nuc. Med. Technol. 21(2):13-27.
  6. Nuclear Safety and Security Commission. 2017a. Enforcement Decree of the Nuclear Safety Act. Article 107.
  7. Nuclear Safety and Security Commission. 2017b. Regulation on the classification of radioactive waste and its self disposal standards. Article 2.