DOI QR코드

DOI QR Code

Influence of shear bolt connections on modular precast steel-concrete composites for track support structures

  • Mirza, Olivia (School of Computing, Engineering & Mathematics, University of Western Sydney) ;
  • Kaewunruen, Sakdirat (Birmingham Centre for Railway Research and Education, School of Civil Engineering, The University of Birmingham)
  • 투고 : 2015.10.28
  • 심사 : 2018.05.10
  • 발행 : 2018.06.10

초록

Through extensive research, there exist a new type of connection between railway bridge girders and steel-concrete composite panels. In addition to conventional shear connectors, newly developed blind bolts have been recently adopted for retrofitting. However, the body of knowledge on their influence and application to railway structures has not been thoroughly investigated. This study has thus placed a particular emphasis on the application of blind bolts on the Sydney Harbour Bridge as a feasible alternative constituent of railway track upgrading. Finite element modeling has been used to simulate the behaviours of the precast steel-concrete panels with common types of bolt connection using commercially available package, ABAQUS. The steel-concrete composite track slabs have been designed in accordance with Australian Standards AS5100. These precast steel-concrete panels are then numerically retrofitted by three types of most practical bold connections: head studded shear connector, Ajax blind bolt and Lindapter hollow bolt. The influences of bolt connections on load and stress transfers and structural behaviour of the composite track slabs are highlighted in this paper. The numerical results exhibit that all three bolts can distribute stresses effectively and can be installed on the bridge girder. However, it is also found that Lindapter hollow bolts are superior in minimising structural responses of the composite track slabs to train loading.

키워드

참고문헌

  1. Akono, A-T., Chen, J. and Kaewunruen, S. (2018), "Friction and fracture characteristics of engineered crumb-rubber concrete at microscopic lengthscale", Constr. Build. Mater., 175, 735-745. https://doi.org/10.1016/j.conbuildmat.2018.04.141
  2. Crawford, R.H. (2009), "Greenhouse gas emissions embodied in reinforced concrete and timber railway sleepers", Environ. Sci. Technol., 43(10), 3885-3890. https://doi.org/10.1021/es8023836
  3. Dassault, S. (2011), Abaqus 6.11 Online Documentation; Vol. 2011_04_07-11.54.48 40404. (Accessed on 25/09/14)
  4. Oehlers, D.J. and Foley, L. (1985), "The fatigue strength of stud shear connections in composite beams", Proceedings of the Institution of Civil Engineers, 79(2), 349-364. https://doi.org/10.1680/iicep.1985.995
  5. Fanaie, N., Ghalamzan Esfahani, F. and Soroushnia, S. (2015), "Analytical study of composite beams with different arrangements of channel shear connectors", Steel Compos. Struct., Int. J., 19(2), 485-501. https://doi.org/10.12989/scs.2015.19.2.485
  6. Griffin, D. (2013), "Design of precast composite steel-concrete panels for track support: For use on the Sydney Harbour Bridge", Thesis; University of Western Sydney, Australia.
  7. Griffin, D.W.P., Mirza, O., Kwok, K. and Kaewunruen, S. (2014), "Composite slabs for railway construction and maintenance: A mechanistic review", The IES Journal Part A: Civil & Structural Engineering, 7(4), 243-262.
  8. Griffin, D.W.P., Mirza, O., Kwok, K. and Kaewunruen, S. (2015), "Finite element modelling of modular precast composites for railway track support structure: A battle to save Sydney Harbour Bridge", Austral. J. Struct. Eng., 16(2), 150-168. https://doi.org/10.1080/13287982.2015.11465187
  9. Hendy, C.R. (2006), "Designers' guide to EN 1994-2 : Eurocode 4, design of steel and composite structures. Part 2, General rules and rules for bridges", Eurocode 4, Design of Steel and Composite Structures, Thomas Telford, London, UK.
  10. International Symposium on Tubular (2009), Tubular Structures XII: Proceedings of the 12th International Symposium on Tubular Structures, Shanghai, China, October.
  11. Kaewunruen, S. (2014), "Impact damage mechanism and mitigation by ballast bonding at railway bridge ends", Int. J. Railway Technol., 3(4), 1-22. https://doi.org/10.4203/ijrt.3.4.1
  12. Kaewunruen, S. and Kimani, S.K. (2017), "Damped frequencies of precast modular steel-concrete composite railway track slabs", Steel Compos. Struct., Int. J., 25(4), 427-442.
  13. Kaewunruen, S., Remennikov, A.M. and Murray, M.H. (2014), "Introducing limit states design concept to concrete sleepers: an Australian experience", Frontiers Mater., 1(8), 1-3.
  14. Kaewunruen, S., Wang, Y. and Ngamkhanong, C. (2018), "Derailment-resistant performance of modular composite rail track slabs", Eng. Struct., 160, 1-11. https://doi.org/10.1016/j.engstruct.2018.01.047
  15. Kimani, S.K. and Kaewunruen, S. (2017), "Free vibrations of precast modular steel-concrete composite railway track slabs", Steel Compos. Struct., Int. J., 24(1), 113-128. https://doi.org/10.12989/scs.2017.24.1.113
  16. Kirkland, B. and Uy, B. (2015), "Behaviour and design of composite beams subjected to flexure and axial load", Steel Compos. Struct., Int. J., 19(3), 615-633. https://doi.org/10.12989/scs.2015.19.3.615
  17. Lam, D. and El-Lobody, E. (2001), "Finite Element Modelling of Headed Stud Shear Connectors in Steel-Concrete Composite Beam", In: (A. Zingoni Ed.), Structural Engineering, Mechanics and Computation, Elsevier Science, Oxford, UK, pp. 401-408.
  18. Lezgy-Nazargah, M. and Kafi, L. (2015), "Analysis of composite steel-concrete beams using a refined high-order beam theory", Steel Compos. Struct., Int. J., 18(6), 1369-1389. https://doi.org/10.12989/scs.2015.18.6.1369
  19. Li, J., Huo, Q., Li, X., Kong, X. and Wu, W. (2014), "Dynamic stiffness analysis of steel-concrete composite beams", Steel Compos. Struct., Int. J., 16(6), 577-593. https://doi.org/10.12989/scs.2014.16.6.577
  20. Li, F., Wu, P. and Liu, D. (2012), "Experimental study on the cable rigidness and static behaviours of AERORail structure", Steel Compos. Struct., Int. J., 12(5), 427-444.
  21. Manalo, A., Aravinthan, T., Karunasena, W. and Ticoalu, A. (2010), "A review of alternative materials for replacing existing timber sleepers", Compos. Struct., 92(3), 603-611. https://doi.org/10.1016/j.compstruct.2009.08.046
  22. Micenko, P. (2014), "Major periodic maintenance: determining asset life, criticality and priority", Proceedings of 2014 RSSB National Turnout Workshop, Brisbane, Australia, May.
  23. Mirza, O. (2008), "Behaviour and design of headed stud shear connectors in composite steel-concrete beams", Ph.D. Thesis; The University of Western Sydney, Kingswood, Australia.
  24. Mirza, O. and Uy, B. (2011), "Behaviour of composite beamcolumn flush end-plate connections subjected to lowprobability, high-consequence loading", Eng. Struct., 33(2), 647-662. https://doi.org/10.1016/j.engstruct.2010.11.024
  25. Mirza, O., Uy, B. and Patel, N. (2010), "Behaviour and strength of shear connectors utilising blind bolting", Proceedings of the 4th International Conference on Steel and Composite Structures, Sydney, Australia, July.
  26. Mirza, O., Kaewunruen, S., Kwok, K. and Giffins, D. (2016), "Design and modelling of pre-cast steel-concrete composites for resilient railway track slabs", Steel Compos. Struct., Int. J., 22(3), 537-565. https://doi.org/10.12989/scs.2016.22.3.537
  27. Nguyen, H.T. and Kim, S.E. (2009), "Finite element modelling of push-out tests for large stud shear connectors", J. Constr. Steel Res., 65(10-11), 1909-1920. https://doi.org/10.1016/j.jcsr.2009.06.010
  28. Pecce, M., Rossi, F., Antonio Bibbo, F. and Ceroni, F. (2012), "Experimental behaviour of composite beams subjected to a hogging moment", Steel Compos. Struct., Int. J., 12(5), 395-412. https://doi.org/10.12989/scs.2012.12.5.395
  29. Remennikov, A.M. and Kaewunruen, S. (2008), "A review of loading conditions for railway track structures due to train and track vertical interaction", Struct. Control Health Monitor., 15(2), 207-234. https://doi.org/10.1002/stc.227
  30. Remennikov, A.M. and Kaewunruen, S. (2014), "Experimental load rating of aged railway concrete sleepers", Eng. Struct., 76(10), 147-162. https://doi.org/10.1016/j.engstruct.2014.06.032
  31. Remennikov, A.M., Murray, M.H. and Kaewunruen, S. (2012), "Reliability based conversion of a structural design code for prestressed concrete sleepers", Proceedings of the Institution of Mechanical Engineers: Part F Journal of Rail and Rapid Transit, 226(2), 155-173. https://doi.org/10.1177/0954409711418754
  32. Shanmugam, N.E., Kumar, G. and Thevendran, V. (2002), "Finite element modelling of double skin composite slabs", Finite Elem. Anal. Des., 38(7), 579-599. https://doi.org/10.1016/S0168-874X(01)00093-2
  33. Shanmuganathan, S., Speers, R., Ruodong, P. and Sriskanthan, S. (2011), "Sydney Harbour Bridge: replacement rail track support", Austroads Bridge Conference, 8th, 2011, Sydney, New South Wales, Australia.
  34. Trebilcock, P. (2004), Architectural Design in Steel, Spon Press, New York, NY, USA.
  35. Vayas, I. (2013), Design of Steel-Concrete Composite Bridges to Eurocodes, CRC Press, Hoboken, NJ, USA.
  36. Yao, H., Goldsworthy, H. and Gad, E. (2008), "Experimental and numerical investigation of the tensile behaviour of blind-bolted T-stub connections to concrete-filled circular columns", Technical Report; J. Struct. Eng., 134(2), p. 198. https://doi.org/10.1061/(ASCE)0733-9445(2008)134:2(198)

피인용 문헌

  1. Resilience and Robustness of Composite Steel and Precast Concrete Track Slabs Exposed to Train Derailments vol.4, pp.None, 2018, https://doi.org/10.3389/fbuil.2018.00060
  2. Application of a newly puzzle shaped crestbond rib shear connector in composite beam using inverted T steel girder: An experimental study vol.79, pp.1, 2021, https://doi.org/10.12989/sem.2021.79.1.117