DOI QR코드

DOI QR Code

Seismic behavior of stiffened concrete-filled double-skin tubular columns

  • Shekastehband, B. (Civil Engineering Department, Urmia University of Technology) ;
  • Mohammadbagheri, S. (Civil Engineering Department, Urmia University of Technology) ;
  • Taromi, A. (Civil Engineering Department, Urmia University of Technology)
  • Received : 2017.08.18
  • Accepted : 2018.03.28
  • Published : 2018.06.10

Abstract

The imperfect steel-concrete interface bonding is an important deficiency of the concrete-filled double skin tubular (CFDST) columns that led to separating concrete and steel surfaces under lateral loads and triggering buckling failure of the columns. To improve this issue, it is proposed in this study to use longitudinal and transverse steel stiffeners in CFDST columns. CFDST columns with different patterns of stiffeners embedded in the interior or exterior surfaces of the inner or outer tubes were analyzed under constant axial force and reversed cyclic loading. In the finite element modeling, the confinement effects of both inner and outer tubes on the compressive strength of concrete as well as the effect of discrete crack for concrete fracture were incorporated which give a realistic prediction of the seismic behavior of CFDST columns. Lateral strength, stiffness, ductility and energy absorption are evaluated based on the hysteresis loops. The results indicated that the stiffeners had determinant role on improving pinching behavior resulting from the outer tube's local buckling and opening/closing of the major tensile crack of concrete. The lateral strength, initial stiffness and energy absorption capacity of longitudinally stiffened columns with fixed-free end condition were increased by as much as 17%, 20% and 70%, respectively. The energy dissipation was accentuated up to 107% for fixed-guided end condition. The use of transverse stiffeners at the base of columns increased energy dissipation up to 35%. Axial load ratio, hollow ratio and concrete strength affecting the initial stiffness and lateral strength, had negligible effect of the energy dissipation of the columns. It was also found that the longitudinal stiffeners and transverse stiffeners have, respectively, negative and positive effects on ductility of CFDST columns. The conclusions, drawn from this study, can in turn, lead to the suggestion of some guidelines for the design of CFDST columns.

Keywords

References

  1. ABAQUS (2012), ABAQUS Standard User's Manual, Version 6.12.: Dassault Systemes Corp., Providence, RI, USA.
  2. ACI (2008), Building code requirements for structural concrete and commentary; ACI 318-08, ACI.
  3. Ahmed, A.S., Ayman, H.H.K. and Osamma, H.A.W. (2005), "Response of concrete filled double skin steel tube columns to axial loads", Proceedings of the 11th International Colloquium on Structural and Geotechnical Engineering, 11(E05RC29), pp. 1-16.
  4. AISC (2010a), Specification for Structural Steel Buildings; ANSI.AISC 360-10, Chicago, IL, USA.
  5. AISC (2010b), Seismic Provisions for Structural Steel Buildings; ANSI/AISC 341, AISC, Chicago, IL, USA.
  6. ATC-24 (1992), Guidelines for Seismic testing of components of steel structures; Report 24, Applied, Redwood City, CA, USA.
  7. Dong, C.X. and Ho, J.C.M. (2012), "Uni-axial behaviour of normal-strength CFDST columns with external steel rings", Steel Compos. Struct., Int. J., 13(6), 587-606. https://doi.org/10.12989/scs.2012.13.6.587
  8. Duarte, A.P.C., Silva, B.A., Silvestre, N., Brito, J. de, Julio, E., Castro, J.M. (2016), "Experimental study on short rubberized concrete-filled steel tubes under cyclic loading", Compos. Struct., 136, 394-404. https://doi.org/10.1016/j.compstruct.2015.10.015
  9. Elchalakani, M., Zhao, X.L. and Grzebieta, R. (2002), "Tests on concrete-filled double-skin composite short columns under axial compression", Thin Wall. Struct., 40(5), 415-441. https://doi.org/10.1016/S0263-8231(02)00009-5
  10. Espinos, A., Romero, M.L. and Hospitaler, A. (2010), "Advanced model for predicting the fire response of concrete filled tubular columns", J. Constr. Steel Res., 66, 1030-1046. https://doi.org/10.1016/j.jcsr.2010.03.002
  11. Eurocode 4 (2005), Design of steel and concrete composite structures: part 1.2 general rules: structural fire design; EC4, Brussels, Belgium.
  12. FEMA (2009), Quantification of Building Seismic Performance Factors; FEMA P-695, USA.
  13. Goto, Y., Kumar, G.P. and Kawanishi, N. (2010), "Nonlinear Finite-Element Analysis for Hysteretic Behavior of Thin-Walled Circular Steel Columns with In-Filled Concrete", J. Struct. Eng., 136, 1413-1422. https://doi.org/10.1061/(ASCE)ST.1943-541X.0000240
  14. Han, L.H., Huang, H., Tao, Z. and Zhao, X.L. (2006), "Concretefilled double skin steel tubular (CFDST) beam-columns subjected to cyclic bending", Eng. Struct., 28(12), 1698-1714. https://doi.org/10.1016/j.engstruct.2006.03.004
  15. Han, L.H., Huang, H. and Zhao, X.L. (2009), "Analytical behaviour of concrete-filled double skin steel tubular (CFDST) beam-columns under cyclic loading", Thin-Wall. Struct., 47, 668-680. https://doi.org/10.1016/j.tws.2008.11.008
  16. Han, T.H., Stallings, J.M. and Kang, Y.J. (2010), "Nonlinear concrete model for double-skinned composite tubular columns", Constr. Build. Mater., 24(12), 2542-2553. https://doi.org/10.1016/j.conbuildmat.2010.06.001
  17. Han, L.H., Ren, Q.X. and Li, W. (2011), "Tests on stub stainless steel-concrete-carbon steel double-skin tubular (DST) columns", J. Constr. Steel Res., 67, 437-452. https://doi.org/10.1016/j.jcsr.2010.09.010
  18. Hassanein, M.F., Kharoob, O.F. and Gardner, L. (2015), "Behaviour and design of square concrete-filled double skin tubular columns with inner circular tubes", Eng. Struct., 100, 410-424. https://doi.org/10.1016/j.engstruct.2015.06.022
  19. Ho, J.C.M. and Dong, C.X. (2014), "Improving strength, stiffness and ductility of CFDST columns by external confinement", Thin-Wall. Struct., 75, 18-29. https://doi.org/10.1016/j.tws.2013.10.009
  20. Hu, H.T. and Su, F.C. (2011), "Nonlinear analysis of short concrete-filled double skin tube columns subjected to axial compressive forces", Marine Struct., 24, 319-337. https://doi.org/10.1016/j.marstruc.2011.05.001
  21. Imani, R., Mosqueda G. and Bruneau, M. (2014), "Post-Earthquake Fire Resistance of Ductile Concrete-Filled Double-Skin Tube Columns, Technical report", MCEER-14-0008.
  22. Imani, R., Mosqueda G. and Bruneau, M. (2015), "Finite Element Simulation of Concrete-Filled Double-Skin Tube Columns Subjected to Postearthquake Fires", J. Struct. Eng., 141(12), 04015055. https://doi.org/10.1061/(ASCE)ST.1943-541X.0001301
  23. Johansson, M. and Gylltoft, K. (2001), "Structural behavior of slender circular steel-concrete composite columns under various means of load application", Steel Compos. Struct., Int. J., 1(4), 393-410. https://doi.org/10.12989/scs.2001.1.4.393
  24. Kim, J.K., Kwak, H.G. and Kwak, J.H. (2013), "Behavior of hybrid double skin concrete filled circular steel tube columns", Steel Compos. Struct., Int. J., 14(2), 191-204. https://doi.org/10.12989/scs.2013.14.2.191
  25. Kojic, M. and Bathe, K.J. (2005), Inelastic Analysis of Solids and Structures, Springer.
  26. Lin, M.L. and Tsai, K.C. (2001), "Behavior of double-skinned composite steel tubular columns subjected to combined axial and flexural loads", Proceedings of the 1st International Conference on Steel & Composite Structures, pp. 1145-1152.
  27. Lu, H., Han, H.L. and Zhao, X.L. (2011), "FE modeling and fire resistance design of concrete filled double skin tubular columns", J. Constr. Steel Res., 67, 1733-1748. https://doi.org/10.1016/j.jcsr.2011.04.014
  28. Mander, J.B., Priestley, M.J.N. and Park, R. (1988), "Theoretical stress-strain model for confined concrete", J. Struct. Eng., 114(8), 1804-1823. https://doi.org/10.1061/(ASCE)0733-9445(1988)114:8(1804)
  29. Nakanishi, K., Kitada, T. and Nakai, H. (1999), "Experimental study on ultimate strength and ductility of concrete filled steel columns under strong earthquakes", J. Constr. Steel Res., 51, 297-319. https://doi.org/10.1016/S0143-974X(99)00006-1
  30. Pagoulatou, M., Sheehan, T., Dai, X.H. and Lam, D. (2014), "Finite element analysis on the capacity of circular concretefilled double-skin steel tubular (CFDST) stub columns", Eng. Struct., 72, 102-112. https://doi.org/10.1016/j.engstruct.2014.04.039
  31. Ren, Q.X., Hou, C., Lam, D. and Han, L.H. (2014), "Experiments on the bearing capacity of tapered concrete filled double skin steel tubular (CFDST) stub columns", Steel Compos. Struct., Int. J., 17(5), 667-686. https://doi.org/10.12989/scs.2014.17.5.667
  32. Richart, F.E., Brandtzaeg, A. and Brown, R.L. (1928), "A study of the Failure of Concrete under Combined Compressive Stresses Bulletin", University of Illinois Engineering Experimental Station, Champaign, IL, USA, Volume 185.
  33. Romero, M.L., Espinos, A., Portoles, J.M., Hospitaler, A. and Ibanez, C. (2015), "Slender double-tube ultra-high strength concrete-filled tubular columns under ambient temperature and fire", Eng. Struct., 99, 536-545. https://doi.org/10.1016/j.engstruct.2015.05.026
  34. Saenz, L.P. (1964), "Discussion of "Equation for the stress-strain curve of concrete", ACI J., 61, 1229-1235.
  35. Shekastehband, B., Taromi, A. and Abedi, K. (2017), "Fire performance of stiffened concrete filled double skin steel tubular columns", Fire Safe. J., 88, 13-25. https://doi.org/10.1016/j.firesaf.2016.12.009
  36. Shimizu, M., Tatsumi, F., Ishikawa, T., Hattori, A. and Kawano, H. (2013), "Experimental study on ultimate strength of concrete filled double tubular steel with shear connector", Int. J. Steel Struct., 13(1), 49-54. https://doi.org/10.1007/s13296-013-1005-x
  37. Talaeitaba, S.B., Halabian, M. and Torki, M.E. (2015), "Nonlinear behavior of FRP-reinforced concrete-filled double-skin tubular columns using finite element analysis", Thin-Wall. Struct., 95, 389-407. https://doi.org/10.1016/j.tws.2015.07.018
  38. Tao, Z., Han, L.H. and Zhao, X.L. (2004), "Behaviour of concretefilled double skin steel tubular stub columns and beamcolumns", J. Constr. Steel Res., 60(8), 1129-1258. https://doi.org/10.1016/j.jcsr.2003.11.008
  39. Tao, Z., Wang, Z.B. and Yu, Q. (2013), "Finite element modelling of concrete-filled steel stub columns under axial compression", J. Constr. Steel Res., 89, 121-131. https://doi.org/10.1016/j.jcsr.2013.07.001
  40. Zhao, X.L., Grzebieta, R.H. and Elchalakani, M. (2002), "Tests of concrete-filled double skin CHS composite stub columns", Steel Compos. Struct., Int. J., 2(2), 129-142. https://doi.org/10.12989/scs.2002.2.2.129
  41. Zhou, F. and Xu, W. (2016), "Cyclic loading tests on concretefilled double-skin (SHS outer and CHS inner) stainless steel tubular beam-columns", Eng. Struct., 127, 304-318. https://doi.org/10.1016/j.engstruct.2016.09.003

Cited by

  1. Behavior of an Innovative Square Composite Column Made of Four Steel Tubes at the Corners and Corrugated Steel Batten Plates on all Sides vol.2019, pp.None, 2018, https://doi.org/10.1155/2019/2971962
  2. Component based moment-rotation model of composite beam blind bolted to CFDST column joint vol.38, pp.5, 2021, https://doi.org/10.12989/scs.2021.38.5.547