DOI QR코드

DOI QR Code

A Study on Reduction Effect of White Smoke Fog in Urban Detention Basin using a Fog Removal System

안개제거장치를 이용한 도심 저류지 시설에서의 안개 저감 효과 연구

  • Received : 2018.11.09
  • Accepted : 2018.11.24
  • Published : 2018.12.31

Abstract

Fog to which environmental impacts are sensitive has a danger to the safety of citizens due to the difficulty in predicting the specific area/time zone. Therefore, we propose a white smoke fog reduction technique using a fog removal device that can remove fog particles directly through dry air and anionic condensation nucleus instead of conventional passive countermeasures. In this study, to verify the effect of reducing fog and the effect of temperature on the white smoke fog which is frequently occurred in the detention basin. As a result, the visible distance of 100m or more was secured within 30 seconds, and it was confirmed that the fog reduction effect is more effective. Also, the lower the temperature, the larger the amount of white smoke fog was. However, the effect of reducing the white smoke fog by temperature was insignificant. Through this experiment, it was possible to verify the reduction effect of the white smoke fog generated in the detention basin through fog removal device.

환경적인 영향에 대해 민감하게 발생하는 안개는 특정 지역/시간대를 예측하기 어려워 시민의 안전에 대한 위험성을 가진다. 따라서 기존의 소극적이고 수동적인 대응방안이 아닌 건조공기와 음이온 응결핵을 통해 안개입자를 직접적으로 제거할 수 있는 안개제거장치를 이용한 백연성 안개 저감 기술을 제안하고자 한다. 이에 본 연구에서는 저류지 환경에서 자주 발생하는 백연성 안개에 대하여 안개제거장치를 이용한 저감 효과를 확인하고 기온 환경에 따른 영향성을 분석하고자 실험적 검증을 수행하였다. 동일한 환경 조건에서 100 m 거리에 위치한 표지판을 설치하여 가시거리를 비교하였다. 그 결과 30초 이내에 100 m 이상의 가시거리를 확보 가능하였으며 이것으로 안개저감효과가 효과적임을 확인할 수 있었다. 또한 기온 환경에 따라 온도가 낮을수록 백연성 안개가 크게 발생하였으나 기온 환경별 백연성 안개의 저감효과에 대한 영향성은 미미한 것을 확인하였다. 본 실험을 통해 안개제거장치를 이용하여 저류지환경에서 발생된 백연성 안개에 대한 저감 효과를 검증할 수 있었다.

Keywords

HKBJBA_2018_v11n2_69_f0001.png 이미지

Fig. 1. Death rate of traffic accident by weather type (2012~2014, Road Traffic Authority)

HKBJBA_2018_v11n2_69_f0002.png 이미지

Fig. 2. The principle of fog removal

HKBJBA_2018_v11n2_69_f0003.png 이미지

Fig. 3. The mimetic diagram of fog removal device

HKBJBA_2018_v11n2_69_f0004.png 이미지

Fig. 4. Examples of fog removal area modeling for the device

HKBJBA_2018_v11n2_69_f0005.png 이미지

Fig. 5. The site of white smoke fog generation – detention basin

HKBJBA_2018_v11n2_69_f0006.png 이미지

Fig. 6. Test set-up

HKBJBA_2018_v11n2_69_f0007.png 이미지

Fig. 7. The amount of white smoke fog according to temperature

HKBJBA_2018_v11n2_69_f0008.png 이미지

Fig. 8. A example of quantitaive evaluation index using image processing

Table 1. Specification of fog removal device

HKBJBA_2018_v11n2_69_t0001.png 이미지

Table 2. Comparison of before and after operation for blower/full systems of fog removal device

HKBJBA_2018_v11n2_69_t0002.png 이미지

Table 3. Reduction effect of white smoke fog by temperature when using 75kW fog removal device

HKBJBA_2018_v11n2_69_t0003.png 이미지

References

  1. Lutgens Tarbuck (2009). THE Atmosphere 10th EDITION, Sigmapress, pp. 163-175.
  2. Kim, J. W., Lee, S. B., and Oh, S. O. (2005). A Study on the Augmentation of Safety in the Road of Frequent Foggy Area. Conference of Korean Society of Civil Engineers. pp. 4198-4201.
  3. Lee, K. S., Kim, S. J., Lee, J. S., and Sung, W. K. (2017). Introduction of Development of counter-fog system to assure over 100 m visibility distance of bridge. Conference of Korean Society of Civil Engineers. pp. 1405-1406.
  4. Lee, K.-H., Yi, W.-H., and Yang, W.-J. (2016). A Study on Risk Analysis of Social Disaster. Journal of Korean Society of Disaster & Security. Vol. 9. No. 2. pp. 15-21. https://doi.org/10.21729/ksds.2016.9.2.15