DOI QR코드

DOI QR Code

Estimation of the Probable Maximum Water Thermal Energy in Korean Dams based on the Water-Energy Nexus Concept

물-에너지 넥서스기반 국내 댐 가능최대 수열에너지 산정

  • Jung, Younghun (Department of Construction & Disaster Prevention Engineering, Kyungpook National University)
  • Received : 2017.10.30
  • Accepted : 2017.12.28
  • Published : 2018.03.31

Abstract

Demand for essential resources including water, energy and food is rapidly increasing due to climate change, population growth and urbanization. To solve this problem, the concept of water-energy-food nexus has been introduced, and many countries have been trying to acquire the Nexus technology that can maximize the efficiency by analyzing the interconnection between resources. In this regard, this study attempted to estimate the probable maximum water thermal energy in the dam based on the water-energy nexus concept. The estimation of the probable maximum water thermal energy was implemented to monthly water storage of the largest dams in the four major river systems. As a result of analyzing the estimated monthly water thermal energy from 2000 to 2016, Soyang River dam has the largest probable maximum water thermal energy, and Sumjin River dam has the smallest. However, the probable maximum water thermal energy was small in common between March and April, between September and October due to the small temperature difference between the ambient air and the dam water. Also, according to the characteristics of the dam, Daecheong dam and Soyang River dam were beneficial for supplying water thermal energy for heating, and Sumjin River dam and Andong dam were advantageous for supplying water thermal energy for cooling. Our findings can be useful to realize the water-energy-food nexus by increasing the utilization and value of water resources as well as expanding the roles and functions of dams as a starting point to use dam water thermal energy.

Keywords

References

  1. Chen, X., G. Zhang, J. Peng, X. Lin, and T. Liu, 2006. The performance of an open-loop lake water heat pump system in south China, Appl. Therm. Eng. 26: 2255-2261. DOI: 10.1016/j.applthermaleng.2006.03.009
  2. Kavanaugh, S. P., 1989. Design considerations for ground and water source heat pumps in southern climates, ASHRAE Trans. 95(1): 1139-1149.
  3. KEMCO, 2016a. New & Renewable Energy Statistics 2015, Korea Energy Agency, Korea.
  4. KEMCO, 2016b. Industry Statistics of New & Renewable Energy 2015, Korea Energy Agency, Korea.
  5. KIER, 2005. The Optimization of Demonstration Network Plant Using Unutilized Energy Resources, 6-116. Ministry of Science and Technology, Korea.
  6. Kim, J., Y. Ryoo, and M. Park, 2015. Analysis of Available Capacity and Relevant Legal System for the Use of Temperature Difference Energy in a Rural Community. New & Renewable Energy, 11(3): 21-27 (in Korean). https://doi.org/10.7849/ksnre.2015.09.11.3.21
  7. Kindaichi, S., D. Nishina, L. Wen, and T. Kannaka, 2015. Potential For Using Water Reservoirs As Heat Sources In Heat Pump Systems, Applied Thermal Engineering, 76: 47-53. DOI:10.1016/j.applthermaleng.2014.10.091
  8. Mitchell, M. S., and J. D. Spitler, 2013. Open-loop direct surface water cooling and surface water heat pump systems-A review, HVAC&R Res., 19: 125-140. DOI: 10.1080/10789669.2012.747374
  9. Park, J. T., and K. C. Chang, 2002. An Investigation on Quantity of Unused Energy Using Temperature Difference Energy as Heat Source and Its Availability, Korean Energy Engg. J., 11(2): 106-113
  10. Peer, T., and W. S. Joyce, 2002. Lake-source cooling, ASHRAE J. ,44(4): 37-39.
  11. Rockstrom, J., W. Steffen, K. Noone, A. Persson, F. S. III. Chapin, E. F. Lambin, T. M. Lenton, M. Scheffer, C. Folke, H. J. Schellnhuber, B. Nykvist, C. A. de Wit, T. Hughes, S. van der Leeuw, H. Rodhe, S. Sorlin, P. K. Snyder, R. Costanza, U. Svedin, M. Falkenmark, L. Karlberg, R. W. Corell, V. J. Fabry, J. Hansen, B. Walker, D. Liverman, K. Richardson, P. Crutzen, and J. A. Foley, 2009. A safe operating space for humanity. Nature, 461: 472-475. doi:10.1038/461472a
  12. Takeshi, K., T. Hiroo, and M. Hisashi, 1993. Possibility of Utilization of River Water as the Heat Source/Sink of Heat-Pump Systems: Part I. In Proceedings of the Annual Conference of Architectural Institute of Japan, 499-500. Tokyo, Japan.