DOI QR코드

DOI QR Code

Seismic protection of smart base-isolated structures using negative stiffness device and regulated damping

  • Bahar, Arash (Department of Civil Engineering, Faculty of Engineering, University of Guilan) ;
  • Salavati-Khoshghalb, Mohsen (Department of Civil Engineering, Faculty of Engineering, University of Guilan) ;
  • Ejabati, Seyed Mehdi (Department of Civil Engineering, Faculty of Engineering, University of Guilan)
  • Received : 2017.07.04
  • Accepted : 2018.02.19
  • Published : 2018.03.25

Abstract

Strong seismic events commonly cause large drift and deformation, and functionality failures in the superstructures. One way to prevent functionality failures is to design structures which are ductile and flexible through yielding when subjected to strong ground excitations. By developing forces that assist motion as "negative stiffness forces", yielding can be achieved. In this paper, we adopt the weakening and damping method to achieve a new approach to reduce all of the structural responses by further adjusting damping phase. A semi-active control system is adopted to perform the experiments. In this adaptation, negative stiffness forces through certain devices are used in weakening phase to reduce structural strength. Magneto-rheological (MR) dampers are then added to preserve stability of the structure. To adjust the voltage in MR dampers, an inverse model is employed in the control system to command MR dampers and generate the desired control forces, where a velocity control algorithm produces initial required control force. An extensive numerical study is conducted to evaluate proposed methodology by using the smart base-isolated benchmark building. Totally, nine control systems are examined to study proposed strategy. Based on the numerical results of seven earthquakes, the use of proposed strategy not only reduces base displacements, base accelerations and base shear but also leads to reduction of accelerations and inter story drifts of the superstructure. Numerical results shows that the usage of inverse model produces the desired regulated damping, thus improving the stability of the structure.

Keywords

References

  1. Attary, N., Symans, M. and Nagarajaiah, S. (2015b), "Development of a rotation-based negative stiffness device for seismic protection of structures", J. Vib. Control, 23(5), 853-867.
  2. Attary, N., Symans, M., Nagarajaiah, S., Reinhorn, A.M., Constantinou, M.C., Taylor, D., Sarlis, A.A., Pasala, D.T.R. (2013), "Performance assessment of a highway bridge structure employing adaptive negative stiffness for seismic protection", Structures Congress 2013: Bridging Your Passion with Your Profession, 1736-1746.
  3. Attary, N., Symans, M., Nagarajaiah, S., Reinhorn, A.M., Constantinou, M.C., Sarlis, A.A., Pasala, D.T.R. and Taylor, D. (2015), "Performance evaluation of negative stiffness devices for seismic response control of bridge structures via experimental shake table tests", J. Earthq. Eng., 19(2), 249-276. https://doi.org/10.1080/13632469.2014.962672
  4. Attary, N., Symans, M., Nagarajaiah, S., Reinhorn, A.M., Constantinou, M.C., Sarlis, A.A., Pasala, D.T.R. and Taylor, D. (2015a), "Numerical simulations of a highway bridge structure employing passive negative stiffness device for seismic protection", Earthq. Eng. Struct. D., 44(6), 973-995. https://doi.org/10.1002/eqe.2495
  5. Attary, N., Symans, M.D., Nagarajaiah, S., Reinhorn, A.M., Constantinou, M.C., Taylor, D., Pasala, D.T.R. and Sarlis, A.A. (2012), "Performance evaluation of seismically isolated bridge structure with adaptive passive negative stiffness", Proceedings of the 15th World Conference on Earthquake Engineering (15WCEE).
  6. Bahar, A., Pozo, F., Acho, L., Rodellar, J. and Barbat, A. (2010), "Parameter identification of large-scale magnetorheological dampers in a benchmark building", Comput. Struct., 88(3), 198-206. https://doi.org/10.1016/j.compstruc.2009.10.002
  7. Bahar, A., Pozo, F., Acho, L., Rodellar, J. and Barbat, A. (2010), "Hierarchical semi-active control of baseisolated structures using a new inverse model of magnetorheological dampers", Comput. Struct., 88(7), 483-496. https://doi.org/10.1016/j.compstruc.2010.01.006
  8. Bossis, G., Khuzir, P., Lacis, S. and Volkova, O. (2003), "Yield behavior of magnetorheological suspensions", J. Magn. Magn. Mater., 258, 456-458.
  9. Charleson, A.W., Wright, P.D. and Skinner, R.I. (1987), "Wellington central police station, base isolation of an essential facility", In Pacific Conference on Earthquake Engineering, 2, 377-388.
  10. Christopoulos, C., Filiatrault, A. and Bertero, V.V. (2006), "Principles of passive supplemental damping and seismic isolation", Iuss Press.
  11. Dyke, S.J., Spencer, B.F., Sain, M.K. and Carlson, J.D. (1996), " Modeling and control of magnetorheological dampers for seismic response reduction", Smart Mater. Struct., 5(5), 565. https://doi.org/10.1088/0964-1726/5/5/006
  12. Dyke, S.J., Spencer, B.F., Sain, M.K. and Carlson, J.D. (1998), "An experimental study of MR dampers for seismic protection", Smart Mater. Struct., 7(5), 693. https://doi.org/10.1088/0964-1726/7/5/012
  13. Hall, J.F., Heaton, T.H. and Halling, M.W. (1995), "Near-source ground motion and its effects on flexible buildings", Earthq. Spectra, 11(4), 569-605. https://doi.org/10.1193/1.1585828
  14. Iemura, H. and Pradono, M.H. (2009), "Advances in the development of pseudo-negative-stiffness dampers for seismic response control", Struct.Control Health Monit., 16(7-8), 784-799.
  15. Jangid, R.S. and Kelly, J.M. (2001), "Base isolation for near-fault motions", Earthq. Eng. Struct. D., 30(5), 691-707. https://doi.org/10.1002/eqe.31
  16. Jung, H.J., Choi, K.M., Spencer, B.F. and Lee, I.W. (2006), "Application of some semi-active control algorithms to a smart base-isolated building employing MR dampers", Struct.Control Health Monit., 13(2-3), 693-704. https://doi.org/10.1002/stc.106
  17. Kelly, J.M. (1999), "The role of damping in seismic isolation", Earthq. Eng. Struct. D., 28(1), 3-20. https://doi.org/10.1002/(SICI)1096-9845(199901)28:1<3::AID-EQE801>3.0.CO;2-D
  18. Makris (1997), "Rigidity-plasticity-viscosity: can electrorheological dampers protect base-isolated structures from near-source ground motions?", Earthq. Eng. Struct. D., 25(6), 571-592.
  19. Naeim, F. and Kelly, J.M. (1999), "Design of seismic isolated structures: from theory to practice", John Wiley & Sons.
  20. Nagarajaiah, S. and Narasimhan, S., "Smart base-isolated benchmark building. Part II: phase I sample controllers for linear isolation systems", Struct. Control Health Monit., 16(2-3), 589-604.
  21. Nagarajaiah, S., Reinhorn, A., Constantinou, M., Taylor, D., Pasala, D.T. and Sirilis, A.A. (2010), "Adaptive negative stiffness: a new structural modification approach for seismic protection", Proceedings of the 5th World Conference on Structural Control and Monitoring, Tokyo, Japan.
  22. Narasimhan, S., Nagarajaiah, S., Johnson, E.A. and Gavin, H.P. (2006), "Smart base-isolated benchmark building. Part I: problem definition", Struct. Control Health Monit., 13(2-3), 573-588. https://doi.org/10.1002/stc.99
  23. Pasala, D.T., Sarlis, A.A., Nagarajaiah, S., Reinhorn, A.M., Nagarajaiah, S., Constantinou, M.C. and Taylor, D. (2012), " Adaptive negative stiffness: New structural modification approach for seismic protection", J. Struct. Eng., 139(7), 1112-23.
  24. Reinhorn, A.M., Viti, S. and Cimellaro, G. (2005), "Retrofit of structures: Strength reduction with damping enhancement", Proceedings of the 37th UJNR panel meeting on wind and seismic effects.
  25. Sarlis, A.A., Pasala, D.T., Constantinou, M.C., Reinhorn, A.M., Nagarajaiah, S. and Taylor, D. (2011), "Negative stiffness device for seismic protection of structures-an analytical and experimental study", In COMPDYN 2011, Proceedings of the 3rd ECCOMAS Thematic Conference on Computational Methods in Structural Dynamics and Earthquake Engineering, Corfu, Greece.
  26. Sarlis, A.A., Pasala, D.T., Constantinou, M.C., Reinhorn, A.M., Nagarajaiah, S. and Taylor, D. (2012), "Negative stiffness device for seismic protection of structures", J. Struct. Eng., 139(7), 1124-1133.
  27. Skinner, R.I., Robinson, W.H. and McVerry, G.H. (1993), "An introduction to seismic isolation", John Wiley & Sons.
  28. Soong, T.T. (1990), "Active structural control: theory and application", New York: Long-an Scientific and Technical Publishing.
  29. Sorace, S. and Terenzi, G. (2008), "Analysis and demonstrative application of a base isolation/supplemental damping technology", Earthq. Spectra, 24(3), 775-793. https://doi.org/10.1193/1.2946441
  30. Spencer, B.F., Dyke, S.J. and Sain, M.K. (1996), "Magnetorheological dampers: a new approach to seismic protection of structures", In Decision and Control, 1996., Proceedings of the 35th IEEE Conference on (Vol. 1, pp. 676-681). IEEE.
  31. Viti, S., Cimellaro, G. and Reinhorn, A.M. (2006), "Retrofit of a hospital through strength reduction and enhanced damping", Smart Struct. Syst., 2(4), 339-355. https://doi.org/10.12989/sss.2006.2.4.339