DOI QR코드

DOI QR Code

Error Analysis of General X-ray Examination by Using Simulation Training

시뮬레이션 교육을 통한 일반 X선 검사의 오류 분석

  • Seoung, Youl-Hun (Department of Radiological Science, College of Health Medical Science, Cheongju University)
  • 성열훈 (청주대학교 보건의료과학대학 방사선학과)
  • Received : 2018.11.07
  • Accepted : 2018.12.31
  • Published : 2018.12.30

Abstract

The purpose of this study was to present simulation training model for general X-ray examinations and to analyze the errors that occur during the simulation training. From 2012 to 2018, a total of 183 students (77 men and 106 women) participated. The simulated X-ray system used computed radiography (CR) system. The contents of simulation training were patient's care, X-ray examinations accuracy, images stability, etc. As a result, it were found that the patient's position setting error, the accuracy error of the X-ray beam central ray, the image receptor's size and setting error, the error of the grid use, the marking error, and the error of X-ray exposure technical factors. It is expected that improved practical general X-ray examinations training of radiographer will be needed, focusing on these errors, so that we could contribute to the health care of the people by providing precise examinations and high quality medical service.

본 연구에서는 일반 X선 검사를 대상으로 시뮬레이션 교육 모델을 제시하고 실습 시 발생하는 오류를 분석하고자 하였다. 2012년부터 2018년까지 총 183명 (남자 77명, 여자 106명)의 학생이 참가하였다. 시뮬레이션 X선 시스템은 컴퓨터방사선영상(computed radiography, CR) 시스템을 이용하였다. 환자 보호, X선 검사의 정확성, 영상의 안정성 등의 검사 프로세스에 발생하는 오류 빈도수를 분석하였다. 그 결과 환자 자세 설정 오류, X선 중심선의 정확성 오류, 영상검출판의 크기 및 위치 설정 오류, 그리드 사용의 오류, 마킹의 오류, X선 조사조건 설정 오류, 조사야 설정의 오류, X선 입사각도의 오류, X선 조사거리의 오류 순으로 분석되었다. 이러한 오류를 중심으로 개선된 방사선사 실습 교육이 필요할 것이며 그로 인하여 정밀한 검사와 고품질의 의료서비스를 제공하여 국민들의 보건의료에 조금이나마 기여할 수 있기를 기대한다.

Keywords

BSSHB5_2018_v12n7_919_f0001.png 이미지

Fig. 1. Analysis of SIPOC for diagnosis X-ray examination.

BSSHB5_2018_v12n7_919_f0002.png 이미지

Fig. 2. Diagnosis X-ray examination simulation training process.

BSSHB5_2018_v12n7_919_f0003.png 이미지

Fig. 3. Observation by monitor for simulation X-ray examination.

BSSHB5_2018_v12n7_919_f0004.png 이미지

Fig. 4. Effective test rate for simulation X-ray examination.

BSSHB5_2018_v12n7_919_f0005.png 이미지

Fig. 5. Analyzed results of error frequency for simulation X-ray examination procedure.

BSSHB5_2018_v12n7_919_f0006.png 이미지

Fig. 6. Analyzed results of error frequency for patient care during simulation X-ray examination.

BSSHB5_2018_v12n7_919_f0007.png 이미지

Fig. 7. Analyzed results of error frequency for accuracy during simulation X-ray examination.

BSSHB5_2018_v12n7_919_f0008.png 이미지

Fig. 8. Analyzed results of error frequency for image stability during simulation X-ray examination.

BSSHB5_2018_v12n7_919_f0009.png 이미지

Fig. 9. Analyzed results of Pareto chart during simulation X-ray examination.

Table 1. Simulation’s X-ray examination kinds

BSSHB5_2018_v12n7_919_t0001.png 이미지

Table 2. Checklist of simulation’s X-ray examination

BSSHB5_2018_v12n7_919_t0002.png 이미지

References

  1. J. H. Kim, S. S. Jin, S. S. Kang, D. H. Kim, C. S. Kim, "Analysis of the Importance of Subjects to Improve the Educational Curriculum in the Radiological Science - Focused on Radiological Technologists," Journal of radiological science and technology, Vol. 35, No. 2, pp. 125-132, 2012.
  2. http://www.arrt.org
  3. http://www.jrcert.org
  4. http://www.hankookilbo.com/News/Read/201407011649856385
  5. S. M. Kwon, K. A. Kim, C. H. Park, "Evaluation of Job Performance of Radiology Students by using Field - based Radiography Course," Journal of the Korea Society of Radiology, Vol. 10, No. 7, pp. 551-557, 2016. https://doi.org/10.7742/jksr.2016.10.7.551
  6. W. J. Choi, D. H. Kim, "Making Human Phantom for X-ray Practice with 3D Printing," Journal of the Korea Society of Radiology, Vol. 11, No. 5, pp. 370-377, 2017
  7. B. R. Park, "Web Information of General Radiography an Cervical Vertebrae Fracture in Patients," Journal of radiological science and technology, Vol. 28, No. 2, pp. 123-128, 2005.
  8. S. C. Kim, "Development of Open Clinical Training Program to Improve Radiology-Major Students' Clinical Competency," Journal of radiological science and technology, Vol. 33, No. 3, pp. 193-201, 2010.
  9. K. C. Lim, "Directions of Simulation-Based Learning in Nursing Practice Education: A Systematic Review," The Journal of Korean Academic Society of Nursing Education, Vol. 17, No. 2, pp. 246-256, 2011. https://doi.org/10.5977/JKASNE.2011.17.2.246
  10. J. B. Cooper, V. R. Taqueti, "A brief history of the development of mannequin simulators for clinical education and training," Quality & Safety in Health Care, Vol. 137, No. 1, pp. 11-18, 2004.
  11. Y. H. Seoung, "A Case Study on the Six Sigma Application to Reduce Waiting Day for Computed Tomography in the Radiology Department," Journal of the Korea safety management & science, Vol. 12 No. 2, pp. 225-230, 2010.
  12. B. S. Kang, K. M. Lee, W. Y. Shim, S. C. Park, H. D. Choi, Y. K. Cho, "Analyze for the Quality Control of General X-ray Systems in Capital region," Journal of the Korean Society of Radiological Technology, Vol. 35, No. 2, pp. 93-102, 2012.
  13. D. H. Hong, H. G. Kim, "Analysis of Bacterial Contamination on Surface of General Radiography Equipment and CT Equipment in Emergency Room of Radiology," Journal of the Korean Society of Radiological Technology, Vol. 39, No. 3, pp. 421-427, 2016. https://doi.org/10.17946/JRST.2016.39.3.17
  14. S. L. Hwang, H. R. Jung, C. H. Lim, "A Study on Radiation Dose for General Radiography Examination at First Medical Institution," Journal of the Korea Society of Radiology, Vol. 5, No. 5, pp. 245-253, 2011. https://doi.org/10.7742/jksr.2011.5.5.245
  15. Y. H. Seoung, S. S. Kim, "Structural Relationship for Recognition of Radiation Risks on Management and Benefits of the University Students," Journal of Digital Convergence, Vol. 12, No. 2, pp. 431-437, 2014. https://doi.org/10.14400/JDC.2014.12.2.431
  16. Y. H. Seoung, "Comparison of Hounsfield Units by Changing in Size of Physical Area and Setting Size of Region of Interest by Using the CT Phantom Made with a 3D Printer," Journal of the Korean Society of Radiological Technology, Vol. 38, No. 4, pp. 421-427, 2015. https://doi.org/10.17946/JRST.2015.38.4.12

Cited by

  1. 3D 프린팅 구조물을 이용한 자기주도 학습방법이 방사선학과 학생들에 미치는 교육 효과 vol.14, pp.1, 2018, https://doi.org/10.7742/jksr.2019.14.1.45