DOI QR코드

DOI QR Code

디지털 흉부 후·전 방향 방사선영상을 이용한 정상 한국인 폐 크기의 영상의학적 계측

Radiological Measurements of Lung Field Size in Normal Korean using Digital Chest Posteroanterior Radiography

  • 박여진 (삼성서울병원 영상의학과) ;
  • 주영철 (삼성서울병원 영상의학과) ;
  • 이일수 (삼성서울병원 영상의학과)
  • 투고 : 2018.01.15
  • 심사 : 2018.02.04
  • 발행 : 2018.02.28

초록

The purpose of this study is to provide baseline data on lung field size measured radiological method by chest PA image in normal Korean. The subject of this study is 496 normal persons who performed chest PA examination using x-ray digital radiography system. The measurement method is from the apex of right and left lung to the costophrenic angle of both lung, from the top of the image to the lowest costophrenic angle of both lung and transverse line of the largest lung area. As a result of this study, the following conclusions were obtained. A lung field size of male is larger than the female(p<0.05). The younger the age, the longer both lung length and total lung height statistically significant. As a increase height and length, A lung field size was increased(p<0.05). But, BMI is not associated with a lung field size. This study will be data of reference data when radiological technologists perform chest PA examination.

키워드

참고문헌

  1. Korean Society of Thoracic Radiology. Imaging Diagnosis of Chest(X-ray). 1st ed. Paju: Koonja; 2012, 1.
  2. Wang JH. Standard protocol of General Radiography. 1st ed. Cheongju: Ministry of Food and Drug Safety; 2014, 2.
  3. Yoon YP. Guideline recommended patient dose of chest X-ray examination. 1st ed. Seoul: Korean Food&Drug Administration; 2008, 1-8.
  4. National Health Insurance Service. Chest radiography results by age. Daegeon: Korean Statistical Information Service; 2017. Avaliable from: http://kosis.kr/statHtml/statHtml.do?orgId=350&tblId=DT_35007_N087&conn_path=I2.
  5. Medical Radiographic Imaging Science Society. Introduction of Radiologic Science. 2nd ed. Seoul: Komoonsa; 2010, 176-320.
  6. Lee JW. Implementation of a systematic radiation management program for reducing the patient dose on digital radiography examinations [dissertation]. Seoul: Kwangwoon University; 2013.
  7. Faculty Council Korean Anatomy Physiology. Human Anatomy. 2nd ed. Seoul: Hyunmoonsa; 2009, 266.
  8. Reginal HT, Chase PP, Hatch KK. Total lung capacity measured by roentgenograms. The American journal of medicine. 1971;50(6):756-63. https://doi.org/10.1016/0002-9343(71)90183-5
  9. Loyd H, Timothy S, DuBois A. Radiographie and plethysmographie determination of total lung capacity. Radiology. 1966;86(1):7-30. https://doi.org/10.1148/86.1.7
  10. Simon G, Reid L, Tanner J, Goldstein H, Benjamin B. Growth of radiologically determined heart diameter, lung width, and lung length from 5-19 years, with standards for clinical use. Archives of disease in Childhood. 1972;47(253):373-81. https://doi.org/10.1136/adc.47.253.373
  11. Jun KS. A Study on the variety of lung field by Respiration Methods. Journal of radiological science and technology. 1979;2(1):55-7.
  12. Kim HG, Ma SC. Measurement of diaphragm in normal human. Journal of radiological science and technology. 2017;30(4):335-41.
  13. Kim HG. A study on the size of lung by Radiographic Method in Normal Korean. Journal of radiological science and technology. 1978;1(1):69-73.
  14. Ministry of Culture, Sports and Tourism. Height comparison of female. Daegeon: Korean Statistical Information Service; 2017. Avaliable from: http://kosis.kr/statHtml/statHtml.do?orgId=113&tblId=DT_113_STBL_1020275&conn_path=I2.
  15. Ministry of Culture, Sports and Tourism. Height comparison of male. Daegeon: Korean Statistical Information Service; 2017. Avaliable from: http://kosis.kr/statHtml/statHtml.do?orgId=113&tblId=DT_113_STBL_1020274&conn_path=I2.