DOI QR코드

DOI QR Code

Simultaneous Measurement of Liquid-level, Concentration and Temperature of a Urea Tank using Ultrasonic and Electrical Conductivity Sensors

초음파와 전기전도 센서를 이용한 우레아 탱크 수위, 농도 및 온도의 동시 측정 방안

  • Choi, Byungchul (School of Mechanical Engineering, Chonnam National University) ;
  • Kim, Taewook (Chonnam National University, graduate student of Depart. of Mechanical Engineering)
  • 최병철 (전남대학교 기계공학부) ;
  • 김태욱 (전남대학교 대학원 기계공학과)
  • Received : 2017.08.02
  • Accepted : 2017.09.28
  • Published : 2017.10.31

Abstract

The purpose of this study is to propose the basic data for the development of a sensor capable of simultaneously measuring the liquid-level, concentration and temperature of a urea tank using ultrasonic and electrical conductivity sensors for diesel vehicles with a urea-SCR system. It was found that the liquid-level of the urea tank using the ultrasonic sensor showed a good linearity with the actual liquid-level, and the urea concentration maintained good linearity in the range of 32.5 wt% to 10 wt%. It was an effective measurement of urea concentration to use the electrical conductivity sensor in the temperature range of $-10{\sim}22^{\circ}C$ and to use the ultrasonic sensor at $22^{\circ}C$ or more. Simultaneous measurement of concentration, liquid-level and temperature of the urea tank will be possible by attaching the electrical conductivity sensor and the ultrasonic sensor (split-type) to one sensor together.

Keywords

References

  1. R. V. Helden and M. V. Gendereren, 2002, "Engine Dynamometer and Vehicle Performance of a Urea SCR-System for Heavy-duty Truck Engines", SAE paper No. 2002-01-0286.
  2. T. V. Johnson, 2006, "Diesel Emission Control in Review", SAE paper No. 2006-01-0030.
  3. C. K. Seo and J. Bae, 2015, "De-NOx Characteristics of $V_2O_5$ SCR According to the Ratio of $TiO_2$ Crystal Structures", Journal of the Korean Society for Power System Engineering, Vol. 19, No. 6, pp. 26-32. https://doi.org/10.9726/kspse.2015.19.6.026
  4. Technical report, 2014, "2012-2016 Global Automotive Sensors Market", Technavio Insights, p. 10.
  5. H. J. Lee and D. M. Seo, 2009, "Ultrasonic Flaw Detecting Test", Enplebooks, Seoul, pp. 36-44.
  6. D. Ensminger and L. J. Bond, 2012, "Ultrasonics", CRC Press, pp. 33-34.
  7. Technical Leaflet, 2006, "AdBlue (BASF)", pp. 1-6.
  8. R. A. Fine and F. J. Millero, 1973, "Compressibility of Water as a Function of Temperature and Pressure", The Journal of Chemical Physics, Vol. 59, No. 10, pp. 5529-5536. https://doi.org/10.1063/1.1679903
  9. A. T. J. Hayward, 1971, "How to Measure the Isothermal Compressibility of Liquids Accurately", Applied Physics, Vol. 4, pp. 938-950.
  10. B. C. Choi, 2017, "A Measuring Device of Level and Concentration of Urea-water Solution Tank of a Urea-SCR System for Automotive Diesel Vehicles using Ultrasonic", Korea patent No. 10-1725108.