References
- Donovan E, Timotin E, Farrell T, Donde B, Puksa S, Sur R. Endobronchial brachytherapy for metastasis from extrapulmonary malignancies as an effective treatment for palliation of symptoms. Brachytherapy. 2017;16:630-8. https://doi.org/10.1016/j.brachy.2017.01.003
- Nag S, Abitbol AA, Anderson LL, Blasko JC, Flores A, Harrison LB, et al. Consensus guidelines for high dose rate remote brachytherapy in cervical, endometrial, and endobronchial tumors. Int J Radiat Oncol Biol Phys. 1993;27:1241-4. https://doi.org/10.1016/0360-3016(93)90549-B
- Bedwinek J, Petty A, Bruton C, Sofield J, Lee L. The use of high dose rate endobronchial brachytherapy to palliate symptomatic endobronchial recurrence of previously irradiated bronchogenic carcinoma. Int J Radiat Oncol Biol Phys. 1992;22:23-30. https://doi.org/10.1016/0360-3016(92)90978-Q
- Kelly JF, Delclos ME, Morice RC, Huaringa A, Allen PK, Komaki R. High-dose-rate endobronchial brachytherapy effectively palliates symptoms due to airway tumors: the 10-year MD Anderson cancer center experience. Int J Radiat Oncol Biol Phys. 2000;48:697-702. https://doi.org/10.1016/S0360-3016(00)00693-3
- Perol M, Caliandro R, Pommier P, Malet C, Montbarbon X, Carrie C, et al. Curative irradiation of limited endobronchial carcinomas with high-dose rate brachytherapy: results of a pilot study. Chest. 1997;111:1417-23. https://doi.org/10.1378/chest.111.5.1417
- Taulelle M, Chauvet B, Vincent P, Felix-Faure C, Buciarelli B, Garcia R, et al. High dose rate endobronchial brachy-therapy: results and complications in 189 patients. Eur Respir J. 1998;11:162-8. https://doi.org/10.1183/09031936.98.11010162
- Mendiondo OA, Dillon M, Beach LJ. Endobronchial brac-hytherapy in the treatment of recurrent bronchogenic carcinoma. Int J Radiat Oncol Biol Phys. 1983;9:579-82. https://doi.org/10.1016/0360-3016(83)90079-2
- Huber RM, Fischer R, Hautmann H, Pollinger R, Wendt T, Muller-Wening D, et al. Palliative endobronchial brachytherapy for central lung tumors: a prospective, randomized comparison of two fractionation schedules. Chest. 1995;107:463-70. https://doi.org/10.1378/chest.107.2.463
- Hennequin C, Tredaniel J, Chevret S, Durdux C, Dray M, Manoux D, et al. Predictive factors for late toxicity after endobronchial brachytherapy: a multivariate analysis. Int J Radiat Oncol Biol Phys. 1998;42:21-7. https://doi.org/10.1016/S0360-3016(98)00032-7
- Langendijk H, de Jong J, Tjwa M, Muller M, ten Velde G, Aaronson N, et al. External irradiation versus external irradiat ion plus endobronchial brachytherapy in inoperable non-small cell lung cancer: a prospective randomized study. Radiother Oncol. 2001;58:257-68. https://doi.org/10.1016/S0167-8140(00)00345-5
- Murakami N, Kobayashi K, Nakamura S, Wakita A, Okamoto H, Tsuchida K, et al. A total EQD2 greater than 85 Gy for trachea and main bronchus D2cc being associated with severe late complications after definitive endobronchial brachytherapy. Journal of Contemporary Brachytherapy. 2016;8:164.
- Moon SY, Jeong E, Lim YK, Chung WK, Huh HD, Kim DW, et al. Feasibility Study of Source Position Verification in HDR Brachytherapy Using Scintillating Fiber. Prog Med Phys. 2016;27:213-9. https://doi.org/10.14316/pmp.2016.27.4.213
- Delclos ME, Komaki R, Morice RC, Allen PK, Davis M, Garden A. Endobronchial brachytherapy with high-doserate remote afterloading for recurrent endobronchial lesions. Radiology. 1996;201:279-82. https://doi.org/10.1148/radiology.201.1.8816560
- Gustafson G, Vicini F, Freedman L, Johnston E, Edmundson G, Sherman S, et al. High dose rate endobronchial bra-chytherapy in the management of primary and recurrent bronchogenic malignancies. Cancer. 1995;75:2345-50. https://doi.org/10.1002/1097-0142(19950501)75:9<2345::AID-CNCR2820750925>3.0.CO;2-M
- Hosni A, Bezjak A, Rink A, Czarnecka K, McPartlin A, Patterson S, et al. High Dose Rate Brachytherapy as a Treatment Option in Endobronchial Tumors. Lung Cancer Int. 2016;2016:3086148.
- Rogus RD, Smith MJ, Kubo HD. An equat ion to QA check the total treatment time for single-catheter HDR brachytherapy. Int J Radiat Oncol Biol Phys. 1998;40:245-8. https://doi.org/10.1016/S0360-3016(97)00487-2
- Wong T, Wallace S, Fernando W, Schumer W, Quong G. Dose errors in the near field of an HDR brachytherapy stepping source. Phys Med Biol. 1999;44:357. https://doi.org/10.1088/0031-9155/44/2/005
- Nath R, Anderson LL, Luxton G, Weaver KA, Williamson JF, Meigooni AS. Dosimetry of interstitial brachytherapy sources: recommendations of the AAPM Radiation Therapy Committee Task Group No. 43. Med Phys. 1995;22:209-34. https://doi.org/10.1118/1.597458
- Fonseca GP, Viana RS, Podesta M, Rubo RA, Sales CP, Reniers B, et al. HDR 192Ir source speed measurements using a high speed video camera. Med Phys. 2015;42:412-5.
- Minamisawa R, Rubo R, Seraide R, Rocha J, Almeida A. Direct measurement of instantaneous source speed for a HDR brachytherapy unit using an optical fiber based detector. Med Phys. 2010;37:5407-11. https://doi.org/10.1118/1.3483780
Cited by
- A 3D-printed patient-specific applicator guide for use in high-dose-rate interstitial brachytherapy for tongue cancer: a phantom study vol.64, pp.13, 2017, https://doi.org/10.1088/1361-6560/ab277e