참고문헌
- Dubojska AM, White GE, Pasiek S. The importance of occlusal balance in the control of complete dentures. Quintessence Int 1998;29:389-94.
- Wong DM, Cheng LY, Chow TW, Clark RK. Effect of processing method on the dimensional accuracy and water sorption of acrylic resin dentures. J Prosthet Dent 1999;81:300-4. https://doi.org/10.1016/S0022-3913(99)70273-8
- Teraoka F, Takahashi J. Controlled polymerization system for fabricating precise dentures. J Prosthet Dent 2000;83:514-20. https://doi.org/10.1016/S0022-3913(00)70007-2
- Peyton FA. History of resins in dentistry. Dent Clin North Am 1975;19:211-22.
- Murray MD, Darvell BW. The evolution of the complete denture base. Theories of complete denture retention-a review. Part 1. Aust Dent J 1993;38:216-9. https://doi.org/10.1111/j.1834-7819.1993.tb03067.x
- Kimoto S, Kobayashi N, Kobayashi K, Kawara M. Effect of bench cooling on the dimensional accuracy of heat-cured acrylic denture base material. J Dent 2005;33:57-63. https://doi.org/10.1016/j.jdent.2004.08.002
- Consani RL, Mesquita MF, Sobrinho LC, Sinhoreti MA. Dimensional accuracy of upper complete denture bases: the effect of metallic flask closure methods. Gerodontology 2009;26:58-64. https://doi.org/10.1111/j.1741-2358.2008.00234.x
- Skinner EW, Cooper EN. Physical properties of denture resins: part I: curing shrinkage and water sorption. J Am Dent Assoc 1943;30:1845-52. https://doi.org/10.14219/jada.archive.1943.0394
- Elahi JM, Abdullah MA. Effect of different polymerization techniques on dimensional stability of record bases. J Prosthet Dent 1994;71:150-3. https://doi.org/10.1016/0022-3913(94)90023-X
- Negreiros WA, Consani RL, Mesquita MF, Sinhoreti MA, Faria IR. Effect of flask closure method and post-pressing time on the displacement of maxillary denture teeth. Open Dent J 2009;3:21-5. https://doi.org/10.2174/1874210600903010021
- Rizzatti-Barbosa CM, Machado C, Joia FA, dos Santos Sousa RL. A method to reduce tooth movement of complete dentures during microwave irradiation processing. J Prosthet Dent 2005;94:301-2. https://doi.org/10.1016/j.prosdent.2005.05.008
- Badel T, Panduric J, Kraljevic S, Dulcic N. Checking the occlusal relationships of complete dentures via a remount procedure. Int J Periodontics Restorative Dent 2007;27:181-92.
- Bidra AS, Taylor TD, Agar JR. Computer-aided technology for fabricating complete dentures: systematic review of historical background, current status, and future perspectives. J Prosthet Dent 2013;109:361-6. https://doi.org/10.1016/S0022-3913(13)60318-2
- Goodacre CJ, Garbacea A, Naylor WP, Daher T, Marchack CB, Lowry J. CAD/CAM fabricated complete dentures: concepts and clinical methods of obtaining required morphological data. J Prosthet Dent 2012;107:34-46. https://doi.org/10.1016/S0022-3913(12)60015-8
- Infante L, Yilmaz B, McGlumphy E, Finger I. Fabricating complete dentures with CAD/CAM technology. J Prosthet Dent 2014;111:351-5. https://doi.org/10.1016/j.prosdent.2013.10.014
- Kattadiyil MT, Goodacre CJ, Baba NZ. CAD/CAM complete dentures: a review of two commercial fabrication systems. J Calif Dent Assoc 2013;41:407-16.
- Kanazawa M, Inokoshi M, Minakuchi S, Ohbayashi N. Trial of a CAD/CAM system for fabricating complete dentures. Dent Mater J 2011;30:93-6. https://doi.org/10.4012/dmj.2010-112
- Inokoshi M, Kanazawa M, Minakuchi S. Evaluation of a complete denture trial method applying rapid prototyping. Dent Mater J 2012;31:40-6. https://doi.org/10.4012/dmj.2011-113
- Baba NZ, AlRumaih HS, Goodacre BJ, Goodacre CJ. Current techniques in CAD/CAM denture fabrication. Gen Dent 2016;64:23-8.
- Wimmer T, Gallus K, Eichberger M, Stawarczyk B. Complete denture fabrication supported by CAD/CAM. J Prosthet Dent 2016;115:541-6. https://doi.org/10.1016/j.prosdent.2015.10.016
- Yamamoto S, Kanazawa M, Iwaki M, Jokanovic A, Minakuchi S. Effects of offset values for artificial teeth positions in CAD/CAM complete denture. Comput Biol Med 2014;52:1-7.
- Yamamoto S, Kanazawa M, Hirayama D, Nakamura T, Arakida T, Minakuchi S. In vitro evaluation of basal shapes and offset values of artificial teeth for CAD/CAM complete dentures. Comput Biol Med 2016;68:84-9. https://doi.org/10.1016/j.compbiomed.2015.11.004
- Sayed ME, Swaid SM, Porwal A. Effect of cast modification on linear dimensional change of acrylic tooth position following maxillary complete denture processing. J Prosthodont 2016 Feb 16.
- Shibayama R, Gennari Filho H, Mazaro JV, Vedovatto E, Assuncao WG. Effect of flasking and polymerization techniques on tooth movement in complete denture processing. J Prosthodont 2009;18:259-64. https://doi.org/10.1111/j.1532-849X.2008.00421.x
- Salloum AM. Effect of three investing materials on tooth movement during flasking procedure for complete denture construction. Saudi Dent J 2016;28:56-61. https://doi.org/10.1016/j.sdentj.2015.08.003
- Kishi M. Experimental studies on the relation between area and displacement of loading surfaces in connection with displaceability in the mucosa of edentulous alveolar ridge under pressure. Shikwa Gakuho 1972;72:17-45.
- Park C, Kim MH, Hong SM, Go JS, Shin BS. A study on the comparison mechanical properties of 3D printing prototypes with laminating direction. J Korean Soc Manufactur Technol Eng 2015;24:334-41. https://doi.org/10.7735/ksmte.2015.24.3.334
- Objet Eden 260VS. Stratasys Ltd., Available at: http://www.stratasys.com