DOI QR코드

DOI QR Code

Clinical In Vivo Bio Assay of Glucose in Human Skin by a Tattoo Film Carbon Nano Tube Sensor

  • Ly, Suw Young (Biosensor research institute, Seoul National University of science & Technology) ;
  • Lee, Chang Hyun (Major in ICT-integrated Environment, Pyeongtaek University)
  • Received : 2017.08.29
  • Accepted : 2017.09.20
  • Published : 2017.09.30

Abstract

In vivo assay of glucose detection was described using a skin tattoo film electrode (STF), and the probe was made from carbon nano tube paste modification film paper. Here in the square-wave stripping anodic working range obtained of $20-100mgL^{-1}$ within an accumulation time of 0 seconds only in sea water electrolyte solutions of pH 7.0. The relative standard deviations of 50 mg glucose that were observed of 0.14 % (n=12), respectively, using optimum stripping accumulation of 30 sec, the low detection limit (S/N) was pegged at 15.8 mg/L. The developed results can be applied to the detect of in vivo skin sensing in real time. Which confirms the results are usable for in vitro or vivo diagnostic clinical analysis.

Keywords

References

  1. Jose M. de Miguel Yanes, Concepcion Gonzalo Hernando, Nuria Munoz Rivas, Manuel Mendez Bailon, Fernando Cava Valenciano, Juan Torres Macho, First plasma glucose value after urgent admission and in-hospital mortality in acutely decompensated heart failure, Heart & Lung 44, 137-140 (2015). https://doi.org/10.1016/j.hrtlng.2014.11.006
  2. Marianne Benn, Anne Tybjaerg Hansen, Mark I. McCarthy, Gorm B. Jensen, Peer Grande, Borge G. Nordestgaard, Nonfasting Glucose, Ischemic Heart Disease, and Myocardial Infarction, Journal of the American College of Cardiology 59(25), 2356-2365 (2012). https://doi.org/10.1016/j.jacc.2012.02.043
  3. Weihua Wu, Zhenjie Sun, Qian Li, Mingli Wang, Jiajing Miao, Zhaohui Zheng, Lifang Sun, Jinwei Huang, Ying Wang, Hongmei Zhang, Chunxiang Hu, Influence of the glucose-lowering rate on left ventricular function in patients with type 2 diabetes and coronary heart disease, Journal of Diabetes and Its Complications 26, 83-88 (2012). https://doi.org/10.1016/j.jdiacomp.2012.02.010
  4. Kai Zhao,Wei Gu, Sisi Zheng,Cuiling Zhangn, Yuez hongXian, SDS-MoS2 nanoparticles ashighly-efficient peroxidasemimetics for color imetric detection of $H_{2}O_{2}$ and glucose, Talanta 141, 47-52 (2015). https://doi.org/10.1016/j.talanta.2015.03.055
  5. Julaluk Noiphung, Temsiri Songjaroen, Wijitar Dungchai, Charles S. Henry, Orawon Chailapakul, Wanida Laiwattanapaisal, Electrochemical detection of glucose from whole blood using paper based microfluidic devices, Analytica Chimica Acta 788, 39- 45 (2015).
  6. Edward L. Hull, Nathaniel I. Matter, Byron P. Olson, Marwood N. Ediger, Andrea J. Magee, Jeff F. Way, Kay E. Vugrin, John D. Maynard, Noninvasive skin fluorescence spectroscopy for detection of abnormal glucose tolerance, Journal of Clinical & Translational Endocrinology 1, 92-99 (2014). https://doi.org/10.1016/j.jcte.2014.06.003
  7. E. Buriova, M. Medova, F. Macasek, P. Bruder, Separation and detection of oxidation products of fluorodeoxyglucose and glucose by high-performance liquid chromatography-electrospray ionisation mass spectrometry, Journal of Chromatography A 1034, 133-137 (2004). https://doi.org/10.1016/j.chroma.2004.01.060
  8. Darja Kotnik, Andrej Smidovnik, Petra Jazbec Krizman, Mitja Krizman, Mirko Prosek, Direct analysis of carbohydrates in animal plasma by ion chromatography coupled with mass spectrometry and pulsed amperometric detection for use as a non-invasive diagnostic tool, Journal of Chromatography B 879, 3700-3706 (2011). https://doi.org/10.1016/j.jchromb.2011.10.010
  9. Uwe Damm, Venkata Radhakrishna Kondepati, H. Michael Heise, Continuous reagent-free bed-side monitoring of glucose in biofluids using infrared spectrometry and micro-dialysis, Vibrational Spectroscopy 43, 184-192 (2007). https://doi.org/10.1016/j.vibspec.2006.07.011
  10. S. B. Hocevar, J. Wang, R. P. Deo, B. Ogorevc, potentiometric Stripping Analysis at Bismuth-Film Electrode Electroanal 14, 112-115 (2002). https://doi.org/10.1002/1521-4109(200201)14:2<112::AID-ELAN112>3.0.CO;2-5
  11. Suw Young Ly, Dal woong Choi, Implementation of a Biocircuit Implants for Neurotransmitter Release During Neuro-Stimulation, Current Neurovascular Research 10, 238-246 (2013). https://doi.org/10.2174/15672026113109990017
  12. Suw Young Ly, Detection of dopamine in the pharmacy with a carbon nanotube paste electrode using voltammetry, Bioelectrochemistry 68, 232-236 (2005).
  13. Suw Young Ly, Yun Kym Kim, Assay of glucose in urine and drinking water with voltammetric working sensors of infrared photo diode electrode, Sensors and Actuators A 127, 41-48 (2006). https://doi.org/10.1016/j.sna.2005.11.016
  14. Suw Young Ly, Hai Soo Yoo, Joon Young Ahn, kwang hee Nama, Pico molar assay of riboflavin in human urine using voltammetry, Food Chemistry 127, 270-274 (2011). https://doi.org/10.1016/j.foodchem.2010.12.107
  15. Suw Young Ly, Hai Soo Yoo, Seung Kyu Chun, Detection of trace metal in distilled alcoholic drinks, Food Chemistry 137, 168-171 (2013). https://doi.org/10.1016/j.foodchem.2012.10.018
  16. Suw Young Ly, Nam Sun Cho, Diagnosis of human hepatitis B virus in non-treated blood by the bovine IgG DNA-linked carbon nanotube biosensor, Journal of Clinical Virology 44, 43-47 (2009). https://doi.org/10.1016/j.jcv.2008.09.005
  17. Suw Young Ly, Yong Hwan Kim, In Kwon Han, In Gul Moon, Woon Won Jung, Sam Young Jung, Hyun Jin Sin, Tae Kee Hong, Myung Hoon Kim, Anodic square-wave stripping voltammetric analysis of epinephrine using carbon fiber microelectrode, Microchemical Journal 82, 113-118 (2006). https://doi.org/10.1016/j.microc.2005.12.002
  18. Suw Young Ly, Hwa Jin Heo, Min Jung Kim, Real Time Analysis of Neurotransmitters in the Brain Using a Micro Electrode System, Current Neurovascular Research 7, 32-38 (2010). https://doi.org/10.2174/156720210790820154
  19. Suw Young Ly, Jung Eun Kim, Woo Yeon Moon, Diagnostic assay of carcinoembryonic antigen tumor markers using a fluorine immobilized biosensor with handmade voltammetric circuit, European Journal of Cancer Prevention 20. 58-62 (2011). https://doi.org/10.1097/CEJ.0b013e328341e2e3
  20. Suw Young Ly, Hal-Soo Yoo, Minki Jung, Kwang Hee Ko, Byung Jin Kim, Ki Chul Lee, Byung Min Choi, Assay of In Vivo Chromium with a Hollow-fiber Dialysis Sensor Toxicol. Res 26, 233-236 (2010). https://doi.org/10.5487/TR.2010.26.3.233