DOI QR코드

DOI QR Code

Structural health monitoring of a newly built high-piled wharf in a harbor with fiber Bragg grating sensor technology: design and deployment

  • Liu, Hong-biao (Tianjin Research Institute for Water Transport Engineering, National Engineering Laboratory for Port Hydraulic Construction Technology) ;
  • Zhang, Qiang (Tianjin Research Institute for Water Transport Engineering, National Engineering Laboratory for Port Hydraulic Construction Technology) ;
  • Zhang, Bao-hua (Tianjin Research Institute for Water Transport Engineering, National Engineering Laboratory for Port Hydraulic Construction Technology)
  • 투고 : 2016.12.19
  • 심사 : 2017.03.30
  • 발행 : 2017.08.25

초록

Structural health monitoring (SHM) of civil infrastructure using fiber Bragg grating sensor networks (FBGSNs) has received significant public attention in recent years. However, there is currently little research on the health-monitoring technology of high-piled wharfs in coastal ports using the fiber Bragg grating (FBG) sensor technique. The benefits of FBG sensors are their small size, light weight, lack of conductivity, resistance corrosion, multiplexing ability and immunity to electromagnetic interference. Based on the properties of high-piled wharfs in coastal ports and servicing seawater environment and the benefits of FBG sensors, the SHM system for a high-piled wharf in the Tianjin Port of China is devised and deployed partly using the FBG sensor technique. In addition, the health-monitoring parameters are proposed. The system can monitor the structural mechanical properties and durability, which provides a state-of-the-art mean to monitor the health conditions of the wharf and display the monitored data with the BIM technique. In total, 289 FBG stain sensors, 87 FBG temperature sensors, 20 FBG obliquity sensors, 16 FBG pressure sensors, 8 FBG acceleration sensors and 4 anode ladders are installed in the components of the back platform and front platform. After the installation of some components in the wharf construction site, the good signal that each sensor measures demonstrates the suitability of the sensor setup methods, and it is proper for the full-scale, continuous, autonomous SHM deployment for the high-piled wharf in the costal port. The South 27# Wharf SHM system constitutes the largest deployment of FBG sensors for wharf structures in costal ports to date. This deployment demonstrates the strong potential of FBGSNs to monitor the health of large-scale coastal wharf structures. This study can provide a reference to the long-term health-monitoring system deployment for high-piled wharf structures in coastal ports.

키워드

과제정보

연구 과제 주관 기관 : Natural Science Foundation of Tianjin

참고문헌

  1. Abe, M., Fujino, Y., Yanagihara, M. and Sato, M. (2000), "Monitoring of Hakucho Suspension Bridge by ambient vibration measurement", In SPIE's 5th Annual International Symposium on Nondestructive Evaluation and Health Monitoring of Aging Infrastructure, International Society for Optics and Photonics.
  2. Ansari, F. (2007), "Practical implementation of optical fiber sensors in civil structural health monitoring", J. Intel. Mat. Syst. Str., 18(18), 879-889. https://doi.org/10.1177/1045389X06075760
  3. Bugaud, M., Ferdinand, P., Rougeault, S., Dewynter-Marty, V., Parniex, P. and Lucas, D. (2000), "Health monitoring of composite plastic waterworks lock gates using in-fiber Bragg grating sensors", Smart Mater. Struct., 9(3), 22-27.
  4. Chan, T.H.T., Yu, L., Tam, H.Y., Ni, Y.Q., Liu, S.Y. and Chung, W. H. (2006), "Fiber Bragg grating sensors for structural health monitoring of Tsing Ma bridge: background and experimental observation", Eng. Struct., 28(5), 648-659. https://doi.org/10.1016/j.engstruct.2005.09.018
  5. Chang, P.C. and Liu, S.C. (2003), "Recent research in nondestructive evaluation of civil infrastructures", J. Mater. Civil Eng. - ASCE, 15(3), 298-304. https://doi.org/10.1061/(ASCE)0899-1561(2003)15:3(298)
  6. Chang, P.C., Flatau, A. and Liu, S.C. (2003), "Review paper: health monitoring of civil infrastructure", Struct. Health Monit., 2(3), 257-267. https://doi.org/10.1177/1475921703036169
  7. Jang, S., Jo, H., Cho, S., Mechitov, K., Rice, J.A., Sim, S.H. and Agha, G. (2010), "Structural health monitoring of a cable-stayed bridge using smart sensor technology: deployment and evaluation", Smart Struct. Syst., 6(5-6), 439-459. https://doi.org/10.12989/sss.2010.6.5_6.439
  8. Chow, H.M., Lam, H.F., Yin, T. and Au, S.K. (2011), "Optimal sensor configuration of a typical transmission tower for the purpose of structural model updating", Struct. Control Health Monit., 18(3), 305-320. https://doi.org/10.1002/stc.372
  9. Doebling, S.W., Farrar, C.R. and Cornwell, P.J. (1997), "A statistical comparison of impact and ambient testing results from the Alamosa Canyon Bridge", Proceedings-SPIE THE international society for optical engineering, 264-270.
  10. Hill, K.O., Fujii, Y., Johnson, D.C. and Kawasaki, B.S. (1978), "Photosensitivity in optical fiber waveguides: application to reflection filter fabrication", Appl. Phys. Lett., 32(10), 647-649. https://doi.org/10.1063/1.89881
  11. Huang, H.B., Yi, T.H. and Li, H.N. (2016), "Canonical correlation analysis based fault diagnosis method for structural monitoring sensor networks", Smart Struct. Syst., 17(6), 1031-1053. https://doi.org/10.12989/sss.2016.17.6.1031
  12. Ko, J.M. and Ni, Y.Q. (2005), "Technology developments in structural health monitoring of large-scale bridges", Eng. Struct., 27(12), 1715-1725. https://doi.org/10.1016/j.engstruct.2005.02.021
  13. Ko, J.M., Ni, Y.Q., Zhou, H.F., Wang, J.Y. and Zhou, X.T. (2009), "Investigation concerning structural health monitoring of an instrumented cable-stayed bridge", Struct. Infrastruct. Eng. Maint., 5(6), 497-513. https://doi.org/10.1080/15732470701627893
  14. Li, H.N., Li, D.S. and Song, G.B. (2004a), "Recent applications of fiber optic sensors to health monitoring in civil engineering", Eng. Struct., 26(11), 1647-1657. https://doi.org/10.1016/j.engstruct.2004.05.018
  15. Li, H.N., Ren, L., Jia, Z.G., Yi, T.H. and Li, D.S. (2016), "State-of-the-art in structural health monitoring of large and complex civil infrastructures", J. Civil Struct. Health Monit., 6(1), 3-16. https://doi.org/10.1007/s13349-015-0108-9
  16. Li, H.N., Sun, H.M. and Song, G. (2004b), "Damage diagnosis of framework structure based on wavelet packet analysis and neural network", Proceedings of the SPIE - The International Society for Optical Engineering, 60(2), 77-82.
  17. Li, H.N., Yi, T.H., Ren, L., Li, D.S. and Huo, L.S. (2014), "Reviews on innovations and applications in structural health monitoring for infrastructures", Struct. Monit. Maint., 1(1), 1-45. https://doi.org/10.12989/SMM.2014.1.1.001
  18. Meltz, G., Morey, W.W. and Glenn, W.H. (1989), "Formation of bragg gratings in optical fibers by a transverse holographic method", Opt. Lett., 14(15), 823-5. https://doi.org/10.1364/OL.14.000823
  19. Moyo, P., Brownjohn, J.M.W., Suresh, R. and Tjin, S.C. (2005), "Development of fiber Bragg grating sensors for monitoring civil infrastructure", Eng. Struct., 27(12), 1828-1834. https://doi.org/10.1016/j.engstruct.2005.04.023
  20. Muller, U.C. and Baier, H. (2005), "Strain and temperature measurement with fiber optic sensors in composite structures: applications for control and health monitoring", Int. J. Rheumatic Diseases, 16(3), 373-375. https://doi.org/10.1111/1756-185X.12004
  21. Ni, Y.Q., Xia, Y., Liao, W.Y. and Ko, J.M. (2009), "Technology innovation in developing the structural health monitoring system for Guangzhou new TV tower", Struct. Control Health Monit., 16(1), 73-98. https://doi.org/10.1002/stc.303
  22. Ni, Y.Q., Ye, X.W. and Ko, J.M. (2010), "Monitoring-based fatigue reliability assessment of steel bridges: analytical model and application", J. Struct. Eng. - ASCE, 136(12), 1563-1573. https://doi.org/10.1061/(ASCE)ST.1943-541X.0000250
  23. Ni, Y.Q., Ye, X.W. and Ko, J.M. (2012), "Modeling of stress spectrum using long-term monitoring data and finite mixture distributions", J. Eng. Mech. - ASCE, 138(2), 175-183. https://doi.org/10.1061/(ASCE)EM.1943-7889.0000313
  24. Ren, L., Jia, Z.G., Li, H.N. and Song, G. (2014), "Design and experimental study on FBG hoop-strain sensor in pipeline monitoring", Opt. Fiber Technol., 20(1), 15-23. https://doi.org/10.1016/j.yofte.2013.11.004
  25. Ren, L., Li, H.N., Sun, L. and Li, D.S. (2004), "Development of tube-packaged FBG strain sensor and application in the vibration experiment of submarine pipeline model", Proceedings of SPIE - The International Society for Optical Engineering, 5634(1), 98-103.
  26. Takeda, N., Okabe, Y., Kuwahara, J., Kojima, S. and Ogisu, T. (2005), "Development of smart composite structures with small-diameter fiber Bragg grating sensors for damage detection: quantitative evaluation of delamination length in CFRP laminates using lamb wave sensing", Compos. Sci. Technol., 65(15-16), 2575-2587. https://doi.org/10.1016/j.compscitech.2005.07.014
  27. Vries, M.D., Bhatia, V., D'Alberto, T., Arya, V. and Claus, R.O. (1998), "Photoinduced grating-based optical fiber sensors for structural analysis and control", Eng. Struct., 20(3), 205-210. https://doi.org/10.1016/S0141-0296(97)00074-6
  28. Worden, K., Farrar, C.R., Haywood, J. and Todd, M. (2008), "A review of nonlinear dynamics applications to structural health monitoring", Struct. Control Health Monit., 15(4), 540-567. https://doi.org/10.1002/stc.215
  29. Ye, X.W., Ni, Y.Q. and Xia, Y.X. (2012), "Distributed strain sensor networks for in-construction monitoring and safety evaluation of a high-rise building", Int. J. Distrib. Sens. N., 11(2012), 34-63.
  30. Yi, T.H., Li, H.N. and Gu, M. (2013a), "Recent research and applications of GPS-based monitoring technology for high-rise structures", Struct. Control Health Monit., 20(5), 649-670. https://doi.org/10.1002/stc.1501
  31. Yi, T.H. Li, H.N. and Sun, H.M. (2013b), "Multi-stage structural damage diagnosis method based on "energy-damage" theory", Smart Struct. Syst., 12(3-4), 345-361. https://doi.org/10.12989/sss.2013.12.3_4.345
  32. Yi, T.H. and Li, H.N. (2012), "Methodology developments in sensor placement for health monitoring of civil infrastructures", Int. J. Distrib. Sens. N., 2012(1550-1329), 601-617.
  33. Yi, T.H., Li, H.N. and Zhang, X.D. (2015), "Health monitoring sensor placement optimization for canton tower using immune monkey algorithm", Struct. Control Health Monit., 22(1), 123-138. https://doi.org/10.1002/stc.1664

피인용 문헌

  1. Monitoring of a Reinforced Concrete Wharf Using Structural Health Monitoring System and Material Testing vol.7, pp.4, 2017, https://doi.org/10.3390/jmse7040084