과제정보
연구 과제 주관 기관 : Natural Science Foundation of Tianjin
참고문헌
- Abe, M., Fujino, Y., Yanagihara, M. and Sato, M. (2000), "Monitoring of Hakucho Suspension Bridge by ambient vibration measurement", In SPIE's 5th Annual International Symposium on Nondestructive Evaluation and Health Monitoring of Aging Infrastructure, International Society for Optics and Photonics.
- Ansari, F. (2007), "Practical implementation of optical fiber sensors in civil structural health monitoring", J. Intel. Mat. Syst. Str., 18(18), 879-889. https://doi.org/10.1177/1045389X06075760
- Bugaud, M., Ferdinand, P., Rougeault, S., Dewynter-Marty, V., Parniex, P. and Lucas, D. (2000), "Health monitoring of composite plastic waterworks lock gates using in-fiber Bragg grating sensors", Smart Mater. Struct., 9(3), 22-27.
- Chan, T.H.T., Yu, L., Tam, H.Y., Ni, Y.Q., Liu, S.Y. and Chung, W. H. (2006), "Fiber Bragg grating sensors for structural health monitoring of Tsing Ma bridge: background and experimental observation", Eng. Struct., 28(5), 648-659. https://doi.org/10.1016/j.engstruct.2005.09.018
- Chang, P.C. and Liu, S.C. (2003), "Recent research in nondestructive evaluation of civil infrastructures", J. Mater. Civil Eng. - ASCE, 15(3), 298-304. https://doi.org/10.1061/(ASCE)0899-1561(2003)15:3(298)
- Chang, P.C., Flatau, A. and Liu, S.C. (2003), "Review paper: health monitoring of civil infrastructure", Struct. Health Monit., 2(3), 257-267. https://doi.org/10.1177/1475921703036169
- Jang, S., Jo, H., Cho, S., Mechitov, K., Rice, J.A., Sim, S.H. and Agha, G. (2010), "Structural health monitoring of a cable-stayed bridge using smart sensor technology: deployment and evaluation", Smart Struct. Syst., 6(5-6), 439-459. https://doi.org/10.12989/sss.2010.6.5_6.439
- Chow, H.M., Lam, H.F., Yin, T. and Au, S.K. (2011), "Optimal sensor configuration of a typical transmission tower for the purpose of structural model updating", Struct. Control Health Monit., 18(3), 305-320. https://doi.org/10.1002/stc.372
- Doebling, S.W., Farrar, C.R. and Cornwell, P.J. (1997), "A statistical comparison of impact and ambient testing results from the Alamosa Canyon Bridge", Proceedings-SPIE THE international society for optical engineering, 264-270.
- Hill, K.O., Fujii, Y., Johnson, D.C. and Kawasaki, B.S. (1978), "Photosensitivity in optical fiber waveguides: application to reflection filter fabrication", Appl. Phys. Lett., 32(10), 647-649. https://doi.org/10.1063/1.89881
- Huang, H.B., Yi, T.H. and Li, H.N. (2016), "Canonical correlation analysis based fault diagnosis method for structural monitoring sensor networks", Smart Struct. Syst., 17(6), 1031-1053. https://doi.org/10.12989/sss.2016.17.6.1031
- Ko, J.M. and Ni, Y.Q. (2005), "Technology developments in structural health monitoring of large-scale bridges", Eng. Struct., 27(12), 1715-1725. https://doi.org/10.1016/j.engstruct.2005.02.021
- Ko, J.M., Ni, Y.Q., Zhou, H.F., Wang, J.Y. and Zhou, X.T. (2009), "Investigation concerning structural health monitoring of an instrumented cable-stayed bridge", Struct. Infrastruct. Eng. Maint., 5(6), 497-513. https://doi.org/10.1080/15732470701627893
- Li, H.N., Li, D.S. and Song, G.B. (2004a), "Recent applications of fiber optic sensors to health monitoring in civil engineering", Eng. Struct., 26(11), 1647-1657. https://doi.org/10.1016/j.engstruct.2004.05.018
- Li, H.N., Ren, L., Jia, Z.G., Yi, T.H. and Li, D.S. (2016), "State-of-the-art in structural health monitoring of large and complex civil infrastructures", J. Civil Struct. Health Monit., 6(1), 3-16. https://doi.org/10.1007/s13349-015-0108-9
- Li, H.N., Sun, H.M. and Song, G. (2004b), "Damage diagnosis of framework structure based on wavelet packet analysis and neural network", Proceedings of the SPIE - The International Society for Optical Engineering, 60(2), 77-82.
- Li, H.N., Yi, T.H., Ren, L., Li, D.S. and Huo, L.S. (2014), "Reviews on innovations and applications in structural health monitoring for infrastructures", Struct. Monit. Maint., 1(1), 1-45. https://doi.org/10.12989/SMM.2014.1.1.001
- Meltz, G., Morey, W.W. and Glenn, W.H. (1989), "Formation of bragg gratings in optical fibers by a transverse holographic method", Opt. Lett., 14(15), 823-5. https://doi.org/10.1364/OL.14.000823
- Moyo, P., Brownjohn, J.M.W., Suresh, R. and Tjin, S.C. (2005), "Development of fiber Bragg grating sensors for monitoring civil infrastructure", Eng. Struct., 27(12), 1828-1834. https://doi.org/10.1016/j.engstruct.2005.04.023
- Muller, U.C. and Baier, H. (2005), "Strain and temperature measurement with fiber optic sensors in composite structures: applications for control and health monitoring", Int. J. Rheumatic Diseases, 16(3), 373-375. https://doi.org/10.1111/1756-185X.12004
- Ni, Y.Q., Xia, Y., Liao, W.Y. and Ko, J.M. (2009), "Technology innovation in developing the structural health monitoring system for Guangzhou new TV tower", Struct. Control Health Monit., 16(1), 73-98. https://doi.org/10.1002/stc.303
- Ni, Y.Q., Ye, X.W. and Ko, J.M. (2010), "Monitoring-based fatigue reliability assessment of steel bridges: analytical model and application", J. Struct. Eng. - ASCE, 136(12), 1563-1573. https://doi.org/10.1061/(ASCE)ST.1943-541X.0000250
- Ni, Y.Q., Ye, X.W. and Ko, J.M. (2012), "Modeling of stress spectrum using long-term monitoring data and finite mixture distributions", J. Eng. Mech. - ASCE, 138(2), 175-183. https://doi.org/10.1061/(ASCE)EM.1943-7889.0000313
- Ren, L., Jia, Z.G., Li, H.N. and Song, G. (2014), "Design and experimental study on FBG hoop-strain sensor in pipeline monitoring", Opt. Fiber Technol., 20(1), 15-23. https://doi.org/10.1016/j.yofte.2013.11.004
- Ren, L., Li, H.N., Sun, L. and Li, D.S. (2004), "Development of tube-packaged FBG strain sensor and application in the vibration experiment of submarine pipeline model", Proceedings of SPIE - The International Society for Optical Engineering, 5634(1), 98-103.
- Takeda, N., Okabe, Y., Kuwahara, J., Kojima, S. and Ogisu, T. (2005), "Development of smart composite structures with small-diameter fiber Bragg grating sensors for damage detection: quantitative evaluation of delamination length in CFRP laminates using lamb wave sensing", Compos. Sci. Technol., 65(15-16), 2575-2587. https://doi.org/10.1016/j.compscitech.2005.07.014
- Vries, M.D., Bhatia, V., D'Alberto, T., Arya, V. and Claus, R.O. (1998), "Photoinduced grating-based optical fiber sensors for structural analysis and control", Eng. Struct., 20(3), 205-210. https://doi.org/10.1016/S0141-0296(97)00074-6
- Worden, K., Farrar, C.R., Haywood, J. and Todd, M. (2008), "A review of nonlinear dynamics applications to structural health monitoring", Struct. Control Health Monit., 15(4), 540-567. https://doi.org/10.1002/stc.215
- Ye, X.W., Ni, Y.Q. and Xia, Y.X. (2012), "Distributed strain sensor networks for in-construction monitoring and safety evaluation of a high-rise building", Int. J. Distrib. Sens. N., 11(2012), 34-63.
- Yi, T.H., Li, H.N. and Gu, M. (2013a), "Recent research and applications of GPS-based monitoring technology for high-rise structures", Struct. Control Health Monit., 20(5), 649-670. https://doi.org/10.1002/stc.1501
- Yi, T.H. Li, H.N. and Sun, H.M. (2013b), "Multi-stage structural damage diagnosis method based on "energy-damage" theory", Smart Struct. Syst., 12(3-4), 345-361. https://doi.org/10.12989/sss.2013.12.3_4.345
- Yi, T.H. and Li, H.N. (2012), "Methodology developments in sensor placement for health monitoring of civil infrastructures", Int. J. Distrib. Sens. N., 2012(1550-1329), 601-617.
- Yi, T.H., Li, H.N. and Zhang, X.D. (2015), "Health monitoring sensor placement optimization for canton tower using immune monkey algorithm", Struct. Control Health Monit., 22(1), 123-138. https://doi.org/10.1002/stc.1664
피인용 문헌
- Monitoring of a Reinforced Concrete Wharf Using Structural Health Monitoring System and Material Testing vol.7, pp.4, 2017, https://doi.org/10.3390/jmse7040084