참고문헌
- ACI318 (1999), Building code requirements for structural concrete, American Concrete Institute; Farmington Hills, MI, USA.
- AISC (1989), Specification for Structural Steel Buildings-Allowable Stress Design and Plastic Design, American Institute of Steel Construction; Chicago, IL, USA.
- ASCE (2010), Minimum Design of Load of buildings and other structures (ASCE/SEI 7-10), American Society of Civil Engineers; Reston, VA, USA.
- Chen, P., Li, H., Sun, S. and Yuan, M. (2006), "A fast construction sequential analysis strategy for tall buildings", Struct. Eng. Mech., 23(6), 675-689. https://doi.org/10.12989/sem.2006.23.6.675
- Choi, C.K. and Kim, E.D. (1985), "Multistory frames under sequential gravity loads", J. Struct. Eng., ASCE, 111(11), 2373-2384. https://doi.org/10.1061/(ASCE)0733-9445(1985)111:11(2373)
- Choi, C.K., Chung, H.K., Lee, L.G. and Wilson, E.L. (1992), "Simplified building analysis with sequential dead loads-CFM", J. Struct. Eng., ASCE, 118(4), 944-954. https://doi.org/10.1061/(ASCE)0733-9445(1992)118:4(944)
- Esmaili, O., Epackachi, S., Mirghaderi, R., Ghalibafian, M. and Taheri, A.A. (2007), "Evaluation of the construction sequence loading effects on seismic performance of high-rise buildings with different structural systems", Proceedings of Ninth Canadian Conference on Earthquake Engineering, Ottawa, Ontario, Canada, 729-738.
- Esmaili, O. (2008), "Considering sequential construction methods of reinforced concrete high-rise buildings with material timedependency effects", M.Sc. Dissertation, University Of Tehran, Iran.
- Kim, H.S. (2013), "Effect of horizontal members on column shortening of reinforced concrete building structure", Struct. Des. Tall Spec. Build., 22(5), 440-453. https://doi.org/10.1002/tal.696
- Kim, H.S. (2015), "Optimum distribution of additional reinforcement to reduce differential column shortening", Struct. Des. Tall Spec. Build., 24(10), 724-738. https://doi.org/10.1002/tal.1208
- Kim, H.S., Jeong, S.H., Shin, S.H. and Park, J.P. (2012a), "Simplified column shortening analysis of a multi-storey reinforced concrete frame", Struct. Des. Tall Spec. Build., 21(6), 405-415. https://doi.org/10.1002/tal.607
- Kim, H.S., Jeong, S.H. and Shin, S.H. (2012b), "Column shortening analysis of tall buildings with lumped construction sequences", Struct. Des. Tall Spec. Build., 21(10), 764-776. https://doi.org/10.1002/tal.650
- Kwak, H.G. and Kim, J.K. (2006), "Time-dependent analysis of RC frame structures considering construction sequences", Build. Environ., 41(10), 1423-1434. https://doi.org/10.1016/j.buildenv.2005.05.013
- Njomo, W.W. and Ozay, G. (2014), "Minimization of differential column shortening and sequential analysis of RC 3D-frames using ANN", Struct. Eng. Mech., 51(6), 989-1003. https://doi.org/10.12989/sem.2014.51.6.989
- Park, S.W., Choi, S.W. and Park, H.S. (2013), "Moving average correction method for compensation of differential column shortenings in high-rise buildings", Struct. Des. Tall Spec. Build., 22(9), 718-728. https://doi.org/10.1002/tal.722
- Saffarini, H.S. and Wilson, E.L. (1983), "New approaches in the structural analysis of building systems", Research Report No. UCB/SEMM-83/08; Department of Civil Engineering, University of California, Berkeley, USA.
- Vafai, A., Ghabdian, M., Estekanchi, H.E. and Desai, C.S. (2009), "Calculation of creep and shrinkage in tall concrete buildings using nonlinear staged construction analysis", Asian J. Civ. Eng., 10(4), 409-426.
피인용 문헌
- The effect of constant and seasonal changes of ambient conditions on long‐term behavior of high‐rise concrete structures vol.27, pp.18, 2018, https://doi.org/10.1002/tal.1548
- Analytical correction of vertical shortening based on measured data in a RC high-rise building vol.10, pp.6, 2020, https://doi.org/10.12989/acc.2020.10.6.527