DOI QR코드

DOI QR Code

The Study of Comparison on Rapping Force on Generation of Corona Discharge Electrode of Electrostatic Precipitator

전기집진장치의 코로나 전류 발생 전극 제작에 따른 추타력 비교에 관한 연구

  • Lee, Kang-Wuk (KC Hanmi Environment Co., Ltd.) ;
  • Park, Jeong-Ho (Department of Environmental Engineering, Gyeongnam National University of Science and Technology) ;
  • Jang, Seong-Ho (Department of Bio-Environmental Energy, Pusan National University) ;
  • Lim, Woo-Taik (Department of Applied Chemistry, Andong National University) ;
  • Suh, Jeong-Min (Department of Bio-Environmental Energy, Pusan National University)
  • 이강욱 (KC한미산업(주)) ;
  • 박정호 (경남과학기술대학교 환경공학과) ;
  • 장성호 (부산대학교 바이오환경에너지학과) ;
  • 임우택 (안동대학교 응용화학과) ;
  • 서정민 (부산대학교 바이오환경에너지학과)
  • Received : 2016.12.07
  • Accepted : 2017.01.03
  • Published : 2017.02.28

Abstract

Rapid industrial development has led to a serious problem of pollution in the industrial sector. With the increasing social need for environmental protection, research on air pollution prevention equipment for reducing pollutants in industrial processes is actively being undertaken. The deterioration of existent, installed facilities, their increased emission rates, and the strengthening of the effluent quality standards make complying with permissible emission standards difficult. In fact, installing new electric precipitators or complementing existent facilities is inevitable. The expansion and complementation of the installed electrical precipitators have led to improvements in dust collection efficiency, shorter working times, and lower costs. Because of its easy installation and simple manufacturing process, the production method with the discharge electrode of an electric precipitator is widely used. The following conclusions were reached by classifying discharge electrodes into four types based on the production method and mutually comparing them by their dust collection efficiency. None of the four types used in this study were damaged by impact. However, we were able to confirm some strain from the compression sites of both type A and type B. Both type B and type C are expected to have greater dust collection efficiencies than the other models due to their large vibration transmissibility. Moreover, the high vibrational energy is expected to cause rapping damage during its operation. Particularly, in the case of type B, some of the strain was found at the end of the compression site. The coupling schemes of both type C and type D are out of vibration transmissibility. On the other hand, the ability to maintain straightness and solidity of the side is regarded as outstanding and stable. Type D has outstanding on-site workability, considering the presence of locking, structural stability, and work conditions. From these experiments, we determined that type C is the most ideal connection method of discharge electrode, considering its construction period of renovation. Type C is inferior to type D with regard to on-site workability. However, type C has outstanding dedusting transmission with regard to the straightness, solidity maintenance, and vibration of shearing stress.

Keywords

References

  1. Bae, S. J., 2012, Design of a guide vane for improving flow uniformity of electrostatic precipitator, Master's Dissertation, Pusan National University, Busan, Korea.
  2. Jaworek, A., Krupa, A., Czech, T., 2007, Modern electrostatic devices and methods for exhaust gas cleaning : A Brief review, J. electro stat., 65(3), 133-155. https://doi.org/10.1016/j.elstat.2006.07.012
  3. Lloyd, D. A., 1998, Electrostatic precipitator handbook, Adam Hilger, Philadelphia, 112-121.
  4. Lee, J. W., Jang, J. S., Lee, S. H., 2011, Numerical investigation on capture of sub-micron particles in electrostatic precipitator without corona discharger, J. ILASS Korea, 16(2), 69-75.
  5. Mizuno, A., 2000, Electrostatic precipitation, IEEE T. Dielect. El. In., 7(5), 615-624. https://doi.org/10.1109/94.879357
  6. Podlinski, J., Niewulis, A., Mizeraczyk, J., 2009, Electro hydrodynamic flow and particle collection efficiency of a spike-plate type electrostatic precipitator, J. Electro Stat., 67(2-3), 99-104. https://doi.org/10.1016/j.elstat.2009.02.009
  7. Ryu, J. Y., Suh, J. M., Park, J. H., Jeon, B. K., Choi, K. C., Son, Y. I., 2007, Study on filter drag due to the change of operation conditions in a pulse air jet-type bag filter, J. Env. sci., 16(4), 449-458.
  8. Suh, J. M., Park, J. H., Cho, J. H., Jin, K. H., Jung, M. S., Yi, P. I., Hong, S. C., Sivakumar, S., Choi, K. C., 2014, Pressure drop predictions using multiple regression model in pulse jet type bag filter without venturi, J. Env. sci. intern., 23(12), 2045-2056. https://doi.org/10.5322/JESI.2014.23.12.2045