DOI QR코드

DOI QR Code

건물용 연료전지 시스템용 연료처리장치와 연료승압 블로워 연계 특성에 관한 연구

A Study on Connection of Fuel Processor and NG blower for Small Commercial Fuel Cell System

  • 김재동 (한국가스공사 가스연구원) ;
  • 장세진 (산업기술대학교 화학공학과) ;
  • 김진욱 (한국가스공사 가스연구원) ;
  • 김봉규 (한국가스공사 가스연구원) ;
  • 한신호 (산업기술대학교 화학공학과) ;
  • 박달영 (한국가스공사 가스연구원)
  • Kim, Jaedong (New Energy Technology Center, KOGAS Research Institute, Korea Gas Corporation) ;
  • Jang, Sejin (Graduate School of Knowledge-based Technology and Energy, Korea Polytechnic University) ;
  • Kim, Bonggyu (New Energy Technology Center, KOGAS Research Institute, Korea Gas Corporation) ;
  • Kim, Jinwook (New Energy Technology Center, KOGAS Research Institute, Korea Gas Corporation) ;
  • Han, Sienho (Graduate School of Knowledge-based Technology and Energy, Korea Polytechnic University) ;
  • Park, Dalryung (New Energy Technology Center, KOGAS Research Institute, Korea Gas Corporation)
  • 투고 : 2017.07.03
  • 심사 : 2017.09.26
  • 발행 : 2017.10.30

초록

건물용 연료전지 시스템은 공기와 수소의 전기화학반응을 통하여 전기와 열을 생산하는 신재생에너지 시스템이다. 국내의 건물용 연료전지 시스템은 매년 수백기가 판매될 정도로 진행이 되고 있으며, 건물용 연료전지 시스템내에 많은 부품이 국내제품이 아닌 외국 제품에 의존하고 있다. 건물용 연료전지시스템의 중요부품인 연료처리장치를 한국가스공사에서 개발하여 현재 장기내구성 평가를 진행하고 있으며, 국내외에서 개발된 연료승압 블로워를 평가하고, 한국가스공사의 연료처리장치와 BOP와 연계하여 평가를 진행하였다. 한국가스공사에서 개발된 연료처리장치는 76%이상의 효율과 3,000시간 운영에도 일정한 성능을 유지하는 것을 확인할 수 있었고, 국내에서 개발된 연료승압 블로워는 후단압력 및 온도에 따른 소비전력의 평가시 국외의 연료승압 블로워와 대등한 특성을 나타내었으며, 연료처리장치와 BOP가 연계된 연료처리장치 모듈평가시에도 우수한 성능을 나타내었다.

The small commercial fuel cell is a new energy system that produces electricity and heat through electrochemical reaction between air and hydrogen. In Korea, hundreds of domestic small commercial fuel cell systems have been installed and operated every years and many parts in fuel cell systems depend on overseas products. KOGAS(Korea Gas Corporation) has developed the fuel processor which is an important part of fuel cell system and has evaluated the long-term durability. And KOGAS has evaluated domestic and overseas NG blower and fuel processor connected to NG blower. The fuel processor developed by KOGAS have maintained an efficiency of 76% and constant performance over 3,000 hours. The NG blower developed in Korea showed similar characteristics as overseas NG blower in the evaluation of power consumption according to rear pressure and outside temperature. The fuel processor module, fuel processor connected to BOP showed excellent performance.

키워드

참고문헌

  1. Cottrell, C. A., Grasman, S. E., Thomas, M., Martin, K. B., Sheffield, J. W., "Stategies for stationary and portable fuel cell markets", Inter. J. of Hydrogen Energy, 36, 7969-7975, (2011) https://doi.org/10.1016/j.ijhydene.2011.01.056
  2. Wang, Y., Chen, K. S., Mishler, J., Cho, S. C., Adroher, X. C., "A review of polymer electrolyte membrane fuel cells: Technology, applications, and needs on fundamental research", Applied Energy, 88, 981-1007, (2011) https://doi.org/10.1016/j.apenergy.2010.09.030
  3. Mahlia, T. M. I., Chan, P. L., "Life cycle cost analysis of fuel cell based cogeneration system for residential application in Malaysia", Renewable and Sustainable Energy Reviews, 15, 416-426, (2011) https://doi.org/10.1016/j.rser.2010.07.041
  4. 지식경제부"가정용 연료전지 모니터링사업 보고서", (2011)
  5. 김재동, "가정용 연료전지 시스템 개발동향 및 전망" 가스안전, 289, 04-13, (2015)
  6. 산업통상자원부"PEM 연료전지용 다목적 부품 공용화 기술개발", (2015)
  7. James Larminie, Andrew Dicks, "Fuel Cell System Explained, Wiley, (2003)
  8. Wolf Vielstich, Arnold Lamm, Hubert A. Gasteiger, "Handbook of Fuel Cells", Wiley, (2003)
  9. Jang, C. M. and Lim, S. J., "Performance analysis of diaphram blower for fuel cell", Proceeding of SAREK Conference, 1006-1011, (2010)