References
- J. H. Hwang, K. H. Lee, Y. B. Choi, B. S. Kang, "Effectiveness evaluation of the tube voltage measurement by using additional filter," Journal of radiological science and technology, Vol. 38, No. 4, pp. 355-363, 2015. https://doi.org/10.17946/JRST.2015.38.4.04
- M. Ganten, B. Radeleff, A. Kampschulte, MD. Daniels, GW. Kauffmann, J. Hansmann, "Comparing image quality of flat-panel chest radiography with storage phosphor radiography and film-screen radiography," American Journal of Roentgenology(AJR), Vol. 181, No. 1, pp. 171-176, 2003. https://doi.org/10.2214/ajr.181.1.1810171
- R. T. M. Van Soldt, D. Zweers, L. van den Berg, J. Geleijns, J. T. Jansen, J. Zoetelief, "Survey of posteroanterior chest radiography in The Netherlands: patient dose and image quality," The British Journal of Radiology(BRIT J RADIOL), Vol. 76, No. 6, pp. 398-405, 2003.
- C. E. Willis, "Strategies for dose reduction in ordinary radiographic examinations using CR and DR," Pediatric Radiology(PEDIATR RADIOL), Vol. 34, No. 3, pp. 196-200, 2004. https://doi.org/10.1007/s00247-004-1269-6
- S. K. Jang, "DAP measurement and patient dose analysis for diagnostic digital radiography system and film-screen system," Korea University, 2012.
- A. D. Wrixon, "New ICRP recommendations. Journal of radiological protection," Vol. 28, No. 2, pp. 161-168, 2008. https://doi.org/10.1088/0952-4746/28/2/R02
- ICRP, "The evolution of system of radiological protection," International commission on radiological protection(ICRP), Vol. 23, No. 2, pp. 129-142, 2003.
- H. L. Arkins, R. G. Fairchild, J. S. Robertson, D. Greenburg, et al, "Effect of absorption edge filters on diagnostic X-ray spectra," Radiology, Vol. 115, No. 2, pp. 431-437, 1975. https://doi.org/10.1148/115.2.431
- M. Y. Kim, "Study for Optimal exposure condition of General Chest Projection using Film, CR, DR," International University of Korea(IUK), 2012.
- ICRP, "Radiological Protection and Safety in Medicine," Pergamon Press, Oxford, Vol. 73, No. 9, 1996.
- L. J. Krof, W. J. Veldkamp, B. J. Mertens, J. P. van Delft, J. Geleijns, "Detection of simulated nodules on clinical radiographs: dose reduction at digital post eroanterior chest radiology," Radiology, Vol. 241, No. 2, pp. 392-398, 2006. https://doi.org/10.1148/radiol.2412051326
- A. B. d. Gonzalez, S. Darby, "Risk of cancer from diagnostic X-rays:estimates for the UK and 14 other countries," Lancet31 Vol. 363, No. 9406 pp. 345-351, 2004. https://doi.org/10.1016/S0140-6736(04)15433-0
- J. Heo, C. G. Kim, I. J. Lee, H. S. Shin, J. C. Park, H. S. Kang, B. S. Ahn, "A study on the effect of rare earth screen filter. Journal of Radiological Science and Technology Vol. No. 1 11, pp. 17-23, 1988.
- J. T. Dobbins, E. Samei, H. G. Chotas, et al, "Chest radiography:optimization of x-ray spectrum for cesium iodide-amorphous silicon flat-panel detector," Radiology, Vol. 226, No. 1, pp. 221-230, 2003. https://doi.org/10.1148/radiol.2261012023
- W. H. Okka, B. S. Claude, S. Michael, et al, "Chest radiography with a flat-panel detector: Image quality with dose reduction after copper filtration," Radiology, Vol. 237, No. 2, pp. 691-700, 2005. https://doi.org/10.1148/radiol.2372041738
- G. J. Yeon, "Flat-panel Digital Radiography of the Chest:comparison patient dose, image quality and DQE using copper Filter," Korea University, 2012.
- K. S. Kim, S. C. Kim, "Comparison of effective dose and Image Quality by additional in Digital Chest tomosynthesis," Vol. 38, No. 4, pp. 347-353, 2015. https://doi.org/10.17946/JRST.2015.38.4.03
- S. H. Kim, The effect of x-ray filter materials in the skin dose and tube loading at x-ray examinations," Eulji University, 2015.
- M. Y. Lee, "The effect of x-ray filter materials in the skin dose and tube loading at x-ray examinations," Korea University, 2005.
- J. S. Lee, S. J. Ko, S. S. Kang, J. H. Kim, H. H. Park, D. H. Kim, C. S. Kim, "Evaluation of Image Quality for Diagnostic Digital Chest Image Using Ion Chamber in the Total Mastectomy," The Journal of the Korea Contents Association(JKCA), Vol. 13, No. 3, pp. 204-210, 2013. https://doi.org/10.5392/JKCA.2013.13.03.204
- B. R. Park, "The Comparative Study of Image Quality and Radiation Dose with Changes of Tube Voltage and Current in Digital Chest Radiography, Kyung Hee University, 2007.
- A. Madani, V. De Maertelaer, J. Zanen, P. A. Gevenois, "Pulmonary emphysema: radiation dose and section thickness at multidetector CT quantification-comparison with macroscopic and microscopic morphemtry," Radiology, Vol. 243, No. 1, pp. 250-257, 2007. https://doi.org/10.1148/radiol.2431060194
- A. Waaijer A, M. Prokop, B. K. Velthuis, C. J. Bakker, G. A. De Kort, M. S. Van Leeuwen, "Circle of Willis at CT angiography: dose reduction and image quality-reducing tube voltage and increasing tube current settings, "Radiology, Vol. 242, No. 3, pp. 832-839, 2007. https://doi.org/10.1148/radiol.2423051191
Cited by
- 치과 방사선 촬영의 부가 필터 사용에 따른 유효선량 평가: 구내 촬영에 대한 PC-Based Monte Carlo Program 분석 vol.15, pp.4, 2017, https://doi.org/10.7742/jksr.2021.15.4.491