DOI QR코드

DOI QR Code

Estimating the Direction and Distance of an Unknown Radiation Source Using RMC

RMC를 이용한 미지 선원의 방향, 거리 예측

  • Received : 2016.03.29
  • Accepted : 2016.09.06
  • Published : 2016.09.25

Abstract

Rotating modulation collimator(RMC) is a remote sensing technique for a radiation source. This paper introduces an RMC system model and its image reconstruction algorithm based on Kowash's research. The reconstructed image can show the direction of a source. However, the distance to the source cannot be recovered. Moreover, the RMC image suffers from $180^{\circ}$ ambiguity. In this paper, we propose a distance estimation method using two RMCs together with a solution to the ambiguity. We also demonstrate its performance using simulated RMC data.

방사능 누출 사고 시 대응이나 핵안보 검증을 위한 핵물질 탐지에 있어서, 방사선을 방출하는 미지의 선원에 대한 위치 정보를 파악하는 것은 중요하다. 그러한 기구 중 하나인 회전 변조 시준기는 미지 선원을 원격 감지하기 위한 장비로서 영상화를 통해 선원의 위치 탐지가 가능하다. 본 논문에서는 Kowash의 연구를 기초로 회전 변조 시준기의 시스템 모델과 그를 영상화하는 알고리즘을 소개한다. 하지만 결과 영상화 이미지는 선원의 방향은 보여줄 수 있으나 선원의 거리를 찾지 못하는 문제점이 있다. 또한 선원의 실제 방향뿐 아니라 $180^{\circ}$ 대칭방향에서도 선원을 추정하는 모호성 문제를 안고 있다. 본 논문에서 우리는 영상화 결과의 방향 대칭적 모호성을 해결하고, 두 대의 RMC를 이용해 거리를 추정하는 방법을 제안한다. 그리고 이를 RMC 시뮬레이션 데이터를 이용하여 성능을 검증한다.

Keywords

References

  1. K. P. Ziock and K. E. Nelson, "Maximum Detector Sizes Required for Orphan Source Detection", Coden Nimaer, vol. 579, no. 1, pp. 357-362, August 2007.
  2. M. Oda, "High-Resolution X-Ray Collimator with Broad Field of View for Astronomical Use", Applied Optics, vol. 4, no. 1, pp. 143, January 1965. https://doi.org/10.1364/AO.4.000143
  3. L. Mertz, "A Dilute Image Transform with Application to an X-Ray Star Camera", Symposium on Modern Optics. Polytechnic Institute of Brooklyn, pp. 787-791, New york, America, March 1967.
  4. B. R. Kowash, "A Rotating Modulation Imager for Orphan Source Search Problem". Ph. D. Dissertation, University of Michigan, September 2008.
  5. F. Knoll, Radiation Detection and Measurement, Fourth edition, Wiley, 2010.
  6. Y. Vardi, L. A. Shepp, L. Kaufman, "A Statistical Model for Positron Emission Tomography", Journal of the American Statistical Association, vol. 80. no. 389, pp. 8-20, March 1985. https://doi.org/10.1080/01621459.1985.10477119
  7. B. R. Kowash, D. K. Wehe, "A unified nearand far-field imaging model for rotating modulation collimators", Nuclear Instruments and Methods in physics Research A, vol. 637, no. 1, pp. 178-184, May 2011. https://doi.org/10.1016/j.nima.2010.12.037
  8. X-5 Monte Carlo Team, MCNP Overview and Theory, Los Alamos National Laboratory, 2008.

Cited by

  1. A Monte Carlo simulation study for the gamma-ray/neutron dual-particle imager using rotational modulation collimator (RMC) vol.38, pp.1, 2018, https://doi.org/10.1088/1361-6498/aaa3c8
  2. Radiation imaging with a rotational modulation collimator (RMC) coupled to a Cs2LiYCl6:Ce (CLYC) detector vol.69, pp.11, 2016, https://doi.org/10.3938/jkps.69.1644
  3. A Monte Carlo simulation for the radiation imaging technique based on the Hemispherical Rotational Modulation Collimator (H-RMC) vol.12, pp.3, 2017, https://doi.org/10.1088/1748-0221/12/03/c03013