DOI QR코드

DOI QR Code

A Study on the Boiling Heat Transfer Characteristics Using Loop Type Thermosyphon

  • HAN, Kyu-il (Department of Mechanical System Engineering, Pukyong National University) ;
  • CHO, Dong-Hyun (Department of Computer Aided Mechanical Design Engineering, Daejin University)
  • Received : 2016.06.30
  • Accepted : 2016.08.29
  • Published : 2016.08.31

Abstract

Flexible two-phase thermosyphons are devices that can transfer large amounts of heat flux with boiling and condensation of working fluid resulting from small temperature differences. A flexible two-phase thermosyphon consists of a evaporator, an insulation unit, and a condenser. The working fluid inside the evaporator is evaporated by heating the evaporator in the lower part of the flexible two-phase thermosyphon and the evaporated steam rises to the condenser in the upper part to transfer heat in response to the cooling fluid outside the tube. The resultant condensed working fluid flows downward along the inside surface of the tube due to gravity. These processes form a cycle. Using R134a refrigerant as the working fluid of a loop type flexible two-phase thermosyphon heat exchanger, an experiment was conducted to analyse changes in boiling heat transfer performances according to differences in the temperature of the oil for heating of the evaporator, the temperature variations of the refrigerant, and the mass flows. According to the results of the present study, the circulation rate of the refrigerant increased and the pressure in the evaporator also increased proportionally as the temperature of the oil in the evaporator increased. In addition, the heat transfer rate of the boiler increased as the temperature of the oil in the evaporator increased.

Keywords

References

  1. Rhi SH, Kim WT, Song KS and Lee Y. 1998. A Design of two-phase loop thermosyphon for telecommunications system (I): Experiments and Visualization, KSME Int J 12(5), 926-941. https://doi.org/10.1007/BF02945560
  2. Han KI, Cho DH and Lim TW. 2005. Characteristics of boiling heat hransfer of thermosyphon heat exchangers with helical grooves.
  3. Kim JS, Bui NH, Kim JW, Kim JH and Jung HS. 1988. Flow visualization of oscillation characteristics of liquid and vapor flow in the oscillating capillary tube heat pipe, KSME Int J 17(10), 1507-1519.
  4. Chen KS and Chang YR. 1988. Steady-state analysis of two-phase natural circulation loop, Int J Heat Mass Transfer 31(5), 931-940. https://doi.org/10.1016/0017-9310(88)90082-8
  5. Knaani A and Zvirin Y. 1994. Bifurcation phenomena in two-phase natural circulation, Int J Multiphase Flow 19(6), 1129-1151. https://doi.org/10.1016/0301-9322(93)90081-5
  6. Lee KW, Chang KC, Lee KJ, Lee YS and Hong SH. 1995. Heat transportation technology separate heat pipe heat exchanger, Energy R&D Technical Analysis Report 17(1&2) 154-166.
  7. Liao Q and Xin MD. 2000. Augmentation of convective heat transfer inside tubes with three-dimensional internal extended surfaces and twisted-tape inserts, Chemical Engineeving Journal 78, 95-105. https://doi.org/10.1016/S1385-8947(00)00134-0
  8. Faghri A, Chen MM and Morgon M. 1989. Haet transfer characterristics in two-phase closed conventional and concentric annular thermosyphons, ASME J of Heat Transfer 111, 611-618. https://doi.org/10.1115/1.3250726
  9. Karl S and Hein A. 1981. Correlations for nucleate boiling heat transfer in forced convection, Int J Heat Mass Transfer 24, 99-107. https://doi.org/10.1016/0017-9310(81)90097-1