DOI QR코드

DOI QR Code

A Numerical Study on the Effect of Pressure Relief Ducts on the Normal Pressure in a Preliminary Design of Honam-Jeju Subsea Tunnel

호남-제주 해저터널 가상설계의 공기압력 제어 덕트가 열차 주행에 미치는 영향에 대한 수치해석 연구

  • Received : 2016.04.26
  • Accepted : 2016.06.13
  • Published : 2016.08.01

Abstract

High-speed trains have been developed widely in European countries and Japan in order to transport large quantity of people and commodities in short time. Additionally, a high speed train is one of the most desirable and environmentally friendly transportation methods. When a high speed train enters a tunnel, aerodynamic resistance is generated suddenly. This resistance causes micro pressure wave and discomfort to passengers. Due to this aerodynamic pressure against the train, a large amount of traction is required for the operation of a train in a tunnel. Therefore, it is essential to incorporate a pressure relief system in a tunnel in order to reduce aerodynamic resistance caused by a high-speed train. A pressure relief duct and a vertical shaft are representative measures in a tunnel. This study represents the effect of pressure relief ducts in order to alleviate positive and negative normal pressures acting on a train. One-dimensional numerical simulations were carried out in order to estimate the effect of pressure relief systems.

최근에는 고속 열차와 관련된 인프라가 발전한 유럽, 일본 같은 고속철도 선진국뿐만 아니라 미국과 중국에서도 고속철도 건설에 대한 구체적인 계획이 증가하고 있으며, 국내의 경우 수도권 광역급행철도(GTX)와 같은 대심도 지하 교통망의 건설이 추진되고 있다. 열차가 고속으로 주행할 경우 발생하는 공기저항을 최대한 감소시키기 위하여 열차의 선두부는 유선형으로 설계된다. 열차가 터널 내로 진입할 때, 터널 내에서 발생한 공기저항으로 인하여 열차가 터널을 주행할 때 개활지에서 주행하는 경우보다 훨씬 큰 동력이 요구된다. 따라서 일반적으로 열차가 터널로 진입할 때 공기저항 저감을 위하여 열차의 주행속도를 감소시킨다. 이렇게 열차의 속도를 감소시킬 경우 고속 열차의 운송 능력 및 장점이 감소되기 때문에 터널 내에서 열차의 주행 시에 발생하는 공기저항을 감소시키는 설비가 필수적이다. 이 연구에서는 터널 내에서 열차의 고속 주행을 위해 필요한 공기압력 제어 시스템의 효과를 분석하기 위하여 터널의 단면적 및 공기압력 제어 덕트의 단면적과 덕트의 간격이 열차 주행으로 인한 공기저항에 미치는 영향을 1차원 네트워크 수치해석 프로그램을 이용하여 분석하였다.

Keywords

References

  1. Atkins, W. S. (1999), Piston relief ducts for AlpTransit Gotthard, The Channel Tunnel Experience, Institution of Engineering and Technology, Conference Publication (Book 433), pp. 20-23.
  2. Barthes, H., Bordas, A. and Bouillot, D. (1994), Tunnels - special works, Proceedings of the Institution of Civil Engineers, The Institution of Civil Engineers, Engineering Channel Tunnel, Part 3: French Sectoin, pp. 63-75.
  3. Fairbairn, A. G. (1995), Tunnel ventilation, including aerodynamic, Proceedings of the Institution of Civil Engineers, The Institution of Civil Engineers, Engineering Channel Tunnel, Part 4: Transport Systems, pp. 32-41.
  4. Henson, D. (1995), Aerodynamics, ventilation and cooling the tunnel, Engineering the Channel Tunnel, Kirkland, J., E&FN SPON/EUROTUNNEL, pp. 217-220.
  5. Reinke, P. and Busslinger, A. (2011), Improvement of aero and thermodynamics of rail tunnels by cross-connections with shut-off devices, Research 2011, HBI Haerter Ltd., Swiss, pp. 38-43.
  6. Southwood, A. J. (1994), The channel tunnel : A designer's perspective, A. J., Mott MacDonald, pp. 11-13.
  7. UIC (2002), Measures to ensure the technical compatibility of high-speed trains, Technical document, Railway Technical Publications UIC leaflet 660, pp. 28-29.
  8. UIC (2005), Determination of railway tunnel cross-sectional area on the basis of aerodynamic considerations, Technical document, Railway Technical PublicationsUIC leaflet 779-11, pp. 13-15.

Cited by

  1. 공기 압력 제어 덕트를 이용한 철도 터널 내 공기 압력 저감에 대한 수치해석 연구 vol.26, pp.5, 2016, https://doi.org/10.7474/tus.2016.26.5.375