초록

Recently, DC distribution systems have become a hot issue because of the increase in digital loads and DC generation systems according to the expansion of renewable energy technologies. To obtain the practical usage of DC electricity, safety should be guaranteed. The main concerns for safety are twofold: one side is human protection against electric shocks, and the other is facility protection from short faults. "Effects of current on human beings and livestock" (IEC 60479) defines a human body impedance model in electric shock conditions that consists of resistive components and capacitive components. Although the human body impedance model properly works in AC electricity, it does not well match with the electric shock behavior in DC electricity. In this study, the contradiction of the human body impedance model defined by IEC 60479 in case of DC electricity is shown through experiments for the human body. From the analysis of experimental results, a novel unified human body impedance model in electric shock conditions is proposed. This model consists of resistive components, capacitive components, and an inductance component. The proposed human impedance model matches well for AC and DC electricity environments in simulation and experiment.

키워드

참고문헌

  1. IEC TR 60755 "General requirements for residual current operated protective devices," 2008.
  2. W. K. Lee, B. H. Han, H. M. Jung, and H. S. kim, "Development of residual current detector for DC distribution system," Korean Power Electronics Annual Conference, pp. 53-54, July 2013.
  3. D. W. Kim, Y. B. Lim, S. I. Lee, J. H. Kim, and D. C. Kang, "Prevention techniques of electrical fire and electrical shock caused by leakage current," Journal of the Korean Institute of Illuminating and Electrical installation Engineers, Vol. 27, pp. 82-87, June 2013.
  4. H. J. Kim, J. B. Baek, G. S. Seo, K. S. Choi, H. S. Bae, and B. H. Cho, "Research on earth leakage circuit breaker for DC-based green home," Korean Power Electronics Annual Conference, pp. 76-77, Nov. 2010.
  5. IEC 60479, "Residual current protective device dependent or independent of line voltage," 2008.
  6. International Electrotechnical commission, "Effects of current on human beings and livestock, Part 1: General aspects," 60479-1, IEC 2005.
  7. W. K. Lee and H. S. Kim, "Development of residual current detector for protecting human and equipment of TN grounding systems in DC power distribution systems," Korean Power Electronics Annual Conference, pp. 64-65, Nov. 2014.