참고문헌
- Paganetti H: Range uncertainties in proton therapy and the role of Monte Carlo simulations. Phys. Med. Biol. 57:R99-R117 (2012) https://doi.org/10.1088/0031-9155/57/11/R99
- Knopf AC, Lomax A: In vivo proton range verification: a review. Phys. Med. Biol. 58:R131-R160 (2012)
- Stichelbaut F, Jongen Y: Verification of the proton beam position in the patient by the detection of prompt gamma-rays emission. Meeting of 39th Particle Therapy Co-Operative Group. (San Francisco, 2003)
- Min CH, Kim CH, Youn MY, Kim JW: Prompt gamma measurements for locating the dose fall-off region in the proton therapy. Appl. Phys. Lett. 89:183517 (2006) https://doi.org/10.1063/1.2378561
- Smeets J, Roellinghoff F, Prieels D, Stichelbaut F, Benilov A, Busca P, Fiorini C, Peloso R, Basilavecchia M, Frizzi T, Dehaes JC Dubus A: Prompt gamma imaging with a slit camera for real-time range control in proton therapy. Phys. Med. Biol. 57:3371-3405 (2012) https://doi.org/10.1088/0031-9155/57/11/3371
- Bom V, Joulaeizadeh L, Beekman F: Real-time prompt gamma monitoring in spot-scanning proton therapy using imaging through a knife-edge-shaped slit. Phys. Med. Biol. 57:297-308 (2012) https://doi.org/10.1088/0031-9155/57/2/297
- Perali I, Celani A, Bombelli L, Fiorini C, Camera F, Clementel E, Henrotin S, Janssens G, Prieels D, Roellinghoff F, Smeets J, Stichelbaut F, Stappen FV: Prompt gamma imaging of proton pencil beams at clinical dose rate. Phys. Med. Biol. 59:5849-5871 (2014) https://doi.org/10.1088/0031-9155/59/19/5849
- Priegnitz M, Helmbrecht S, Janssens G, Perali I, Smeets J, Stappen FV, Sterpin E, Fiedler F: Detection of mixed-range proton pencil beams with a prompt gamma slit camera. Phys. Med. Biol. 61:855-871 (2016) https://doi.org/10.1088/0031-9155/61/2/855
- Frandes M, Zoglauer A, Maxim V, Prost R: A tracking Compton-scattering imaging system for hadron therapy monitoring. IEEE Trans. Nuc. Sci. 57:144-150 (2010) https://doi.org/10.1109/TNS.2009.2031679
- Richard MH, Chevallier M, Dauvergne D, Freud N, Henriquet P, Foulher Le, Letang JM, Montarou G, Ray C, Roellinghoff F, Testa E, Testa M, Walenta AH: Design guidelines for a double scattering Compton camera for prompt-gamma imaging during ion beam therapy: a Monte Carlo simulation study. IEEE Trans. Nuc. Sci. 58:87-94 (2011) https://doi.org/10.1109/TNS.2010.2076303
- Polf JC, Avery S, Mackin DS, Beddar S: Evaluation of a stochastic reconstruction algorithm for use in Compton camera imaging and beam range verification from secondary gamma emission during proton therapy. Phys. Med. Biol. 57:3537-3553 (2012) https://doi.org/10.1088/0031-9155/57/11/3537
- Krimmer J, Ley JL, Abellan C, Cachemiche JP, Caponetto L, Chen X, Dahoumane M, Dauvergne D, Freud N, Joly B, Lambert D, Lestand L, Letang JM, Magne M, Mathez H, Maxim V, Montarou G, Morel C, Pinto M, Ray C, Reithinger V, Testa E, Zoccarato Y: Development of a Compton camera for medical applications based on silicon strip and scintillation detectors. Nucl. Instrum. Meth. A 787:98-101 (2014)
- Mackin D, Peterson S, Beddar S, Polf JC: Imaging of prompt gamma rays emitted during delivery of clinical proton beams with a Compton camera: Feasibility studies for range verification. Phys. Med. Biol. 60:7085-7099 (2015) https://doi.org/10.1088/0031-9155/60/18/7085
- Kim CH, Park JH, Seo H, Lee HR: Gamma electron vertex imaing and application to beam range verification in proton therapy. Med. Phys. 39:1001-1005 (2012)
- Lee HR, Park JH, Kim JH, Jung WG, Kim CH: Development of signal processing modules for double-sided silicon strip detector of gamma vertex imaging for proton beam dose verification. J. Radiat. Prot. 39(2):81-88 (2014) https://doi.org/10.14407/jrp.2014.39.2.081
-
Golnik C, Hueso-Gonzalez F, Muller A, Dendooven P, Enghardt W, Fiedler F, Kormoll T, Roemer K, Petzoldt J, Wagner A, Pausch G: Range assessment in particle therapy based on prompt
${\gamma}$ -ray timing measurements. Phys. Med. Biol. 59:5399-5422 (2014) https://doi.org/10.1088/0031-9155/59/18/5399 - Hueso-Gonzalez F, Enghardt W, Fiedler F, Golnik C, Janssens G, Petzoldt J, Prieels D, Priegnitz M, Romer K, Smeets J: First test of the prompt gamma ray timing method with heterogeneous targets at a clinical roton therapy facility. Phys. Med. Biol. 60:6247-6272 (2015) https://doi.org/10.1088/0031-9155/60/16/6247
- Min CH, Lee HR, Kim CH, Lee SB: Development of array- type prompt gamma measurement system for in vivo range verification in proton therapy. Med. Phys. 39:2100-2107 (2012) https://doi.org/10.1118/1.3694098
- 이한림, 박종훈, 김한성, 김찬형: 다채널 방사선 측정 장치의 데이터 획득 채널수 저감을 위한 멀티플렉싱 시스템 개발. 2013 춘계학술발표회 논문요약집 대한방사선방어학회. 140-141 (2013)
피인용 문헌
- Correction of Prompt Gamma Distribution for Improving Accuracy of Beam Range Determination in Inhomogeneous Phantom vol.28, pp.4, 2016, https://doi.org/10.14316/pmp.2017.28.4.207