참고문헌
- Australian Orthopaedic Association (2013), National joint replacement registry, Analysis of state & territory health data all arthroplasty. Supplementary Report 2013.
- Bergmann, G., Graichen, F., Bender, A., Rohlmann, A., Halder, A., Beier, A. and Westerhoff, P. (2011), "In vivo gleno-humeral joint loads during forward flexion and abduction", J. Biomech., 44(8), 1543-1552. https://doi.org/10.1016/j.jbiomech.2011.02.142
- Buchler, P., Ramaniraka, N.A., Rakotomanana, L.R., Iannotti, J.P. and Farron, A. (2002), "A finite element model of the shoulder: application to the comparison of normal and osteoarthritic joints", Clinical Biomech., 17(9), 630-639. https://doi.org/10.1016/S0268-0033(02)00106-7
- Burkhart, T.A., Andrews, D.M. and Dunning, C.E. (2013), "Finite element modeling mesh quality, energy balance and validation methods: A review with recommendations associated with the modeling of bone tissue", J. Biomech., 46(9), 1477-1488. https://doi.org/10.1016/j.jbiomech.2013.03.022
- Day, J.S., Lau, E., Ong, K.L., Williams, G.R., Ramsey, M.L. and Kurtz, S.M. (2010), "Prevalence and projections of total shoulder and elbow arthroplasty in the United States to 2015", J. Shoulder Elbow Surgery, 19(8), 1115-1120. https://doi.org/10.1016/j.jse.2010.02.009
- Favre, P., Senteler, M., Hipp, J., Scherrer, S., Gerber, C. and Snedeker, J.G. (2012), "An integrated model of active glenohumeral stability", J. Biomech., 45(13), 2248-2255. https://doi.org/10.1016/j.jbiomech.2012.06.010
- Fox, J.A., Cole, B.J., Romeo, A.A., Meininger, A.K., Williams, J.M., Glenn, R.E. and Dorow, C.B. (2008), "Articular cartilage thickness of the humeral head: an anatomic study", Orthopedics, 31(3), 216.
- Gatti, C.J., Maratt, J.D., Palmer, M.L., Hughes, R.E. and Carpenter, J.E. (2010), "Development and validation of a finite element model of the superior glenoid labrum", Ann. Biomed. Eng., 38(12), 3766-3776. https://doi.org/10.1007/s10439-010-0105-4
- Gupta, S., Van der Helm, F.C.T. and Van Keulen, F. (2004), "Stress analysis of cemented glenoid prostheses in total shoulder arthroplasty", J. Biomech., 37(11), 1777-1786. https://doi.org/10.1016/j.jbiomech.2004.02.001
- Hopkins, A.R., Hansen, U.N., Amis, A.A., Taylor, M., Gronau, N. and Anglin, C. (2006), "Finite element modelling of glenohumeral kinematics following total shoulder arthroplasty", J. Biomech., 39(13), 2476-2483. https://doi.org/10.1016/j.jbiomech.2005.07.031
- Hwang, E., Carpenter, J.E., Hughes, R.E. and Palmer, M.L. (2014), "Shoulder labral pathomechanics with rotator cuff tears", J. Biomech., 47(7), 1733-1738. https://doi.org/10.1016/j.jbiomech.2014.01.036
- Illyes, A . and Kiss, R.M. (2005), "Shoulder muscle activity during pushing, pulling, elevation and overhead throw", J. Electromy. Kinesiol., 15(3), 282-289. https://doi.org/10.1016/j.jelekin.2004.10.005
- Ludewig, P.M. and Cook, T.M. (2000), "Alterations in shoulder kinematics and associated muscle activity in people with symptoms of shoulder impingement", Phys. Therapy, 80(3), 276-291.
- Maldonado, Z.M., Seebeck, J., Heller, M.O., Brandt, D., Hepp, P., Lill, H. and Duda, G.N. (2003), "Straining of the intact and fractured proximal humerus under physiological-like loading", J. Biomech., 36(12), 1865-1873. https://doi.org/10.1016/S0021-9290(03)00212-4
- Mather, J., MacDermid, J.C., Faber, K.J. and Athwal, G.S. (2013), "Proximal humerus cortical bone thickness correlates with bone mineral density and can clinically rule out osteoporosis", J. Shoulder Elbow Surgery, 22(6), 732-738. https://doi.org/10.1016/j.jse.2012.08.018
- Matsen, F.A., (1993), The Shoulder: A Balance of Mobility and Stability: workshop, Vail, Colorado, September.
- Metan, S.S., Krishna, P. and Mohankumar, G.C. (2014), "FEM model an effective tool to evaluate von mises stresses in shoulder joint and muscles for adduction and abduction", Procedia Mater. Sci., 5, 2090-2098. https://doi.org/10.1016/j.mspro.2014.07.544
- New Zealand Joint Registry (2013), The New Zealand joint registry - fifteen year report - January 1999 to December 2013.
- Quental, C., Folgado, J., Fernandes, P.R. and Monteiro, J. (2012), "Bone remodelling analysis of the humerus after a shoulder arthroplasty", Medical Eng. Phys., 34(8), 1132-1138. https://doi.org/10.1016/j.medengphy.2011.12.001
- Ramos, A. and Simoes, J.A. (2006), "Tetrahedral versus hexahedral finite elements in numerical modelling of the proximal femur", Medical Eng. Phys., 28(9), 916-924. https://doi.org/10.1016/j.medengphy.2005.12.006
- Relvas, C., Ramos, A., Completo, A. and Simoes, J.A. (2011), "Accuracy control of complex surfaces in reverse engineering", Int. J. Precision Eng. Manufact., 12(6), 1035-1042. https://doi.org/10.1007/s12541-011-0138-0
- Sahara, W., Sugamoto, K., Murai, M., Tanaka, H. and Yoshikawa, H. (2007), "The three-dimensional motions of glenohumeral joint under semi-loaded condition during arm abduction using vertically open MRI", Clinical Biomech., 22(3), 304-312. https://doi.org/10.1016/j.clinbiomech.2006.04.012
- Tadepalli, S.C., Erdemir, A. and Cavanagh, P.R. (2011), "Comparison of hexahedral and tetrahedral elements in finite element analysis of the foot and footwear", J. Biomech., 44(12), 2337-2343. https://doi.org/10.1016/j.jbiomech.2011.05.006
- Taylor, M. and Prendergast, P.J. (2015), "Four decades of finite element analysis of orthopaedic devices: Where are we now and what are the opportunities?", J. Biomech., 48(5), 767-778. https://doi.org/10.1016/j.jbiomech.2014.12.019
- Tingart, M.J., Lehtinen, J., Zurakowski, D., Warner, J.J. and Apreleva, M. (2006), "Proximal humeral fractures: regional differences in bone mineral density of the humeral head affect the fixation strength of cancellous screws", J. Shoulder Elbow Surgery, 15(5), 620-624. https://doi.org/10.1016/j.jse.2005.09.007
- Tsukerman, I. and Plaks, A. (1998), "Comparison of accuracy criteria for approximation of conservative fields on tetrahedra", Proceedings of the IEEE transactions on magnetics, 34(5), 3252-3255. https://doi.org/10.1109/20.717763
- Varghese, B., Short, D. and Hangartner, T. (2012), "Development of quantitative computed-tomographybased strength indicators for the identification of low bone-strength individuals in a clinical environment", Bone, 50(1), 357-363. https://doi.org/10.1016/j.bone.2011.10.014
- Varghese, B., Short, D., Penmetsa, R., Goswami, T. and Hangartner, T. (2011), "Computed-tomographybased finite-element models of long bones can accurately capture strain response to bending and torsion", J. Biomech., 44(7), 1374-1379. https://doi.org/10.1016/j.jbiomech.2010.12.028
- Westerhoff, P., Graichen, F., Bender, A., Halder, A., Beier, A., Rohlmann, A. and Bergmann, G. (2012), "In vivo measurement of shoulder joint loads during walking with crutches", Clinical Biomech., 27(7), 711-718. https://doi.org/10.1016/j.clinbiomech.2012.03.004
- Yeh, L., Kwak, S., Kim, Y.S., Chou, D.S., Muhle, C., Skaf, A., ... and Resnick, D. (1998), "Evaluation of articular cartilage thickness of the humeral head and the glenoid fossa by MR arthrography: anatomic correlation in cadavers", Skeletal radiol., 27(9), 500-504. https://doi.org/10.1007/s002560050427
- Yongpravat, C., Kim, H.M., Gardner, T.R., Bigliani, L.U., Levine, W.N. and Ahmad, C.S. (2013), "Glenoid implant orientation and cement failure in total shoulder arthroplasty: a finite element analysis", J. Shoulder Elbow Surgery, 22(7), 940-947. https://doi.org/10.1016/j.jse.2012.09.007