References
- American Society of Civil Engineers (ASCE) (2010), Guidelines for electrical transmission line structural loading, third edition, ASCE Manuals and Reports on Engineering Practice, 74. Reston, VA, USA.
- CIGRE (Conseil International des Grands Reseaux Electriques/ International Council on Large Electrical Systems) (2009), "Overhead line design guidelines for mitigation of severe wind storm damage", Scientific Committee B2 on Overhead Lines, B2. 06.09.
- Darwish, M.M., Damatty, A.A.E. and Hangan, H. (2010), "Dynamic characteristics of transmission line conductors and behaviour under turbulent downburst loading", Wind Struct., 13(4), 327-346. https://doi.org/10.12989/was.2010.13.4.327
- Dempsey, D. and White, H.B. (1996), "Winds wreak havoc on lines", Transmission & Distribution World, 48(6), 32-42.
- El Damatty, A.A. and Hamada, A. (2013), "Behaviour of guyed transmission line structures under tornado wind loads -Case studies", Electrical Transmission and Substation Structures 2012: Solutions to Building the Grid of Tomorrow, November 4, 2012 -November 8, American Society of Civil Engineers (ASCE), Columbus, OH, United states, 193-204.
- Hamada, A. (2009), Analysis and behaviour of guyed transmission line structure under tornado wind loading. School of Graduate and Postdoctoral Studies, University of Western Ontario, London, Ontario, Canada.
- Hamada, A., Damatty, A.A.E., Hangan, H. and Shehata, A.Y. (2010), "Finite element modelling of transmission line structures under tornado wind loading", Wind Struct., 13(5), 451-469. https://doi.org/10.12989/was.2010.13.5.451
- Hamada, A. and El Damatty, A.A. (2011), "Behaviour of guyed transmission line structures under tornado wind loading",Comput. Struct., 89(11-12), 986-1003. https://doi.org/10.1016/j.compstruc.2011.01.015
- Hamada, A. and El Damatty, A.A. (2014), "Nonlinear formulation of four-noded cable element and application to transmission lines under tornadoes", Proceedings of the 2014 International Conference on Advances in Wind and Structures (AWAS14) - ACEM14, Busan, Korea, Montreal, Canada, 24-28 August, 2014.
- Hamada, A. and El Damatty, A.A. (2015), "Failure analysis of guyed transmission lines during F2 tornado event", Eng. Struct., 85, 11-25. https://doi.org/10.1016/j.engstruct.2014.11.045
- Hangan, H. and Kim, J.D. (2008), "Swirl ratio effects on tornado vortices in relation to the Fujita scale", Wind Struct., 11(4), 291-302. https://doi.org/10.12989/was.2008.11.4.291
- Holmes, J.D., Hangan, H., Schroder J.L. and Letchford, C.W. (2008), "A forensic study of the Lubbock-Reese downdraft of 2002", Wind Struct., 11(2), 137-152. https://doi.org/10.12989/was.2008.11.2.137
- Holmes, J.D. (2008), "Recent development in specifications of wind loads on transmission lines", Wind Eng., 5(1), 8-18.
- Koziey, B.L. (1993), Formulation and applications of consistent shell and beam elements, Ph.D. McMaster University (Canada), Canada.
- Lee, W.C. and Wurman, J. (2005). "Diagnosed three-dimensional axisymmetric structure of the Mulhall tornado on 3 May 1999", J. Atmos. Sci., 62(7), 2373-2393. https://doi.org/10.1175/JAS3489.1
- Loredo-Souza, A. and Davenport, A.G. (1998), "The effects of high winds on transmission lines", J. Wind Eng. Ind. Aerod., 76, 987-994.
- Sarkar, P., Haan, F., Gallus, Jr., W., Le, K. and Wurman, J. (2005), "Velocity measurements in a laboratory tornado simulator and their comparison with numerical and full-scale data", Proceedings of the 37th Joint Meeting Panel on Wind and Seismic Effects.
- Savory, E., Parke, G.A.R., Zeinoddini, M., Toy, N. and Disney, P. (2001), "Modelling of tornado and microburst-induced wind loading and failure of a lattice transmission tower", Eng. Struct., 23(4), 365-375. https://doi.org/10.1016/S0141-0296(00)00045-6
- Shehata, A.Y., El Damatty, A.A. and Savory, E. (2005), "Finite element modeling of transmission line under downburst wind loading", Finite Elem. Anal. Des., 42(1), 71-89. https://doi.org/10.1016/j.finel.2005.05.005
- Wen, Y. (1975), "Dynamic tornadic wind loads on tall buildings", ASCE Struct. Division, 101(1), 169-185.
Cited by
- The response of a guyed transmission line system to boundary layer wind vol.139, 2017, https://doi.org/10.1016/j.engstruct.2017.01.047
- Statistical Analysis of Wind-Induced Dynamic Response of Power Towers and Four-Circuit Transmission Tower-Line System vol.2018, pp.1875-9203, 2018, https://doi.org/10.1155/2018/5064930
- Empirical numerical model of tornadic flow fields and load effects vol.32, pp.4, 2016, https://doi.org/10.12989/was.2021.32.4.371