DOI QR코드

DOI QR Code

Seismic evaluation and retrofitting of reinforced concrete buildings with base isolation systems

  • Vasiliadis, Lazaros K. (Department of Civil Engineering, Institute of Structural Mechanics and Earthquake Engineering Democritus University of Thrace)
  • Received : 2014.11.12
  • Accepted : 2015.11.08
  • Published : 2016.02.25

Abstract

A parametric study on the nonlinear seismic response of isolated reinforced concrete structural frame is presented. Three prototype frames designed according to the 1954 Hellenic seismic code, with number of floor ranging from 1 to 3 were considered. These low rise frames are representative of many existing reinforced concrete buildings in Greece. The efficacy of the implementation of both lead rubber bearings (LRB) and friction pendulum isolators (FPI) base isolation systems were examined. The selection of the isolation devices was made according to the ratio $T_{is}/T_{fb}$, where Tis is the period of the base isolation system and $T_{bf}$ is the period of the fixed-base building. The main purpose of this comprehensive study is to investigate the effect of the isolation system period on the seismic response of inadequately designed low rise buildings. Thus, the implementation of isolation systems which correspond to the ratio $T_{is}/T_{fb}$ that values from 3 to 5 is studied. Nonlinear time history analyses were performed to investigate the response of the isolated structures using a set of three natural seismic ground motions. The evaluation of each retrofitting case was made in terms of storey drift and storey shear force while in view of serviceability it was made in terms of storey acceleration. Finally, the maximum developed displacements and the residual displacements of the isolation systems are presented.

Keywords

References

  1. Alhan, C. and Gavin, H.P. (2005), "Reliability of base isolation for the protection of critical equipment from earthquake hazards", Eng. Struct., 27(9), 1435-1449. https://doi.org/10.1016/j.engstruct.2005.04.007
  2. Antonopoulos, T.A. and Anagnostopoulos, S.A. (2012), "Seismic evaluation and upgrading of RC buildings with weak open ground stories", Earthq. Struct., 3(3-4), 611-628. https://doi.org/10.12989/eas.2012.3.3_4.611
  3. Applied Technology Council (1996), Seismic Evaluation and Retrofit of Concrete Buildings (ATC-40), Redwood City, CA.
  4. Cardone, D., Flora, A. and Gesualdi, G. (2013), "Inelastic response of RC frame buildings with seismic isolation", Earthq. Eng. Struct. Dyn., 42(6), 871-889. https://doi.org/10.1002/eqe.2250
  5. Constantinou, M., Mokha, A. and Reinhorn, A. (1990), "Teflon bearings in base isolation II: Modeling", J. Struct. Eng., 116(2), 455-474. https://doi.org/10.1061/(ASCE)0733-9445(1990)116:2(455)
  6. European Committee for Standardization (2009), EN 15129:2009, Anti-seismic devices, Brussels, Belgium.
  7. European Committee for Standardization (2005), EN 1998-3-2005, Eurocode 8: Design of structures for earthquake resistance-Part 3: assessment and retrofitting of buildings, Brussels, Belgium.
  8. Favvata, M.J., Naoum, M.C. and Karayannis, C.G. (2013), "Limit states of RC structures with first floor irregularities", Struct. Eng. Mech., 47(6), 791-818 https://doi.org/10.12989/sem.2013.47.6.791
  9. FEMA 310 (1998), Handbook for the seismic evaluation of buildings-A prestandard, ASCE.
  10. Kampas, G. and Makris, N. (2012), "Time and frequency domain identification of seismically isolated structures: advantages and limitations", Earthq. Struct., 3(3-4), 249-270. https://doi.org/10.12989/eas.2012.3.3_4.249
  11. KAN.EPE. (2012), Greek Retrofitting Code, Greek Organization for Seismic Planning and Protection (OASP), Greek Ministry for Environmental Planning and Public Works, Athens. (in Greek)
  12. Kelly, J.M. (1997), Earthquake-Resistant Design with Rubber (2nd Edition.), Springer-Verlag, London, UK.
  13. Kelly, J.M. (1998), "Seismic isolation of civil buildings in the USA", Pro. Struct. Eng. Mater., 1(3), 279-285. https://doi.org/10.1002/pse.2260010309
  14. Kelly, J.M. (1999), "Role of damping in seismic isolation", Earthq. Eng. Struct. Dyn., 28(1), 3-20. https://doi.org/10.1002/(SICI)1096-9845(199901)28:1<3::AID-EQE801>3.0.CO;2-D
  15. Kelly, T.E. (2001), Base Isolation of Structures, Holmes, Cosulting Group Ltd, Auckland, New Zealand.
  16. Guide specifications for seismic isolation design (1991), American association of state highway and transportation officials, Washington, DC.
  17. Konstantinidis, D. and Makris, N. (2006), "Experimental and analytical studies on the seismic response of freestanding and restrained laboratory equipment", Proceedings of the 8th US national conference on earthquake engineering (CD).
  18. Kunnath, S.K., Hoffmann, G. and Reinhorn, A.M. (1995), "Gravity-load-designed reinforced concrete buildings-Part I: seismic evaluation of existing construction", ACI Struct. J., 92(3), 343-354.
  19. Makris, N. and Kampas, G. (2013), "The engineering merit of the "Effective Period" of bilinear isolation systems", Earthq. Struct., 4(4), 397-428. https://doi.org/10.12989/eas.2013.4.4.397
  20. Manoukas, G., Athanatopoulou, G. and Avramidis, I. (2011), "Static pushover analysis based on an energyequivalent SDOF system", Earthq. Spectra, 27(1), 89-105. https://doi.org/10.1193/1.3535597
  21. Manoukas, G., Athanatopoulou, G. and Avramidis, I. (2012), "Multimode pushover analysis for asymmetric buildings under biaxial seismic excitation based on a new concept of the equivalent single degree of freedom system", Soil Dyn. Earthq. Eng., 38, 88-96. https://doi.org/10.1016/j.soildyn.2012.01.018
  22. Mavronicola, E. and Komodromos, P. (2014),"On the response of base-isolated buildings using bilinear models for LRBs subjected to pulse-like ground motions: sharp vs. smooth behavior", Earthq. Struct., 7(6), 1223-1240. https://doi.org/10.12989/eas.2014.7.6.1223
  23. Mistakidis, E.S., De Matteis, G. and Formisano, A. (2006), "Low yield metal shear panels as an alternative for the seismic upgrading of concrete structures", Adv. Eng. Soft., 38(8-9), 626-636. https://doi.org/10.1016/j.advengsoft.2006.08.043
  24. Mokha, A.S., Amin, N., Constantinou, M.C. and Zayas, V. (1996), "Seismic isolation retrofit of large historic building", J. Struct. Eng., 122(3), 298-309. https://doi.org/10.1061/(ASCE)0733-9445(1996)122:3(298)
  25. Naeim, F. and Kelly, J.M. (1999), Design of seismic isolated structures, Wiley, New York, USA.
  26. Nagarajaiah, S., Reinhorn, A.M. and Constantinou, M.C. (1991), 3D-Basis: Non-Linear Dynamic Analysis of Three-Dimensional Base Isolated Structures: Part II, Technical Report NCEER-91-0005, National Center for Earthquake Engineering Research, State University of New York at Buffalo, Buffalo, USA.
  27. Park, Y.J., Wen, Y.K. and Ang, A.H.S. (1986), "Random vibration of hysteretic systems under bi-directional ground motions", Earthq. Eng. Struct. Dyn., 14(4), 543-557. https://doi.org/10.1002/eqe.4290140405
  28. Providakis, C.P. (2008), "Effect of LRB isolators and supplemental viscous dampers on seismic isolated buildings under near-fault excitations", Eng. Struct., 30(5), 1187-1198. https://doi.org/10.1016/j.engstruct.2007.07.020
  29. RD (1959), Earthquake design regulation of building works, Royal Decree (19/26.02.1959), Ministry of Public Works, Greece. (in Greek)
  30. Skinner, R.I., Robinson, W.H. and McVerry, G.H. (1993), An introduction to seismic isolation, John Wiley and Sons, London, UK.
  31. Su, L., Ahmadi, G. and Tadjbakhsh, J.G. (1989), "A comparative study of performances of various base isolation systems, part I: Shear beam structures", Earthq. Eng. Struct. Dyn., 18(1), 11-32. https://doi.org/10.1002/eqe.4290180104
  32. Thermou, G.E. and Pantazopoulou, S.J. (2011), "Assessment indices for the seismic vulnerability of existing R.C. buildings", Earthq. Eng. Struct. Dyn., 40, 293-313. https://doi.org/10.1002/eqe.1028
  33. Varnava, V. and Komodromos, P. (2013), "Assessing the effect of inherent nonlinearities in the analysis and design of a low-rise base isolated steel building", Earthq. Struct., 5(5), 499-526. https://doi.org/10.12989/eas.2013.5.5.499
  34. Wen, Y.K. (1976), "Method for random vibration of hysteretic systems", J. Eng. Mech. Div., 102(2), 249-263.

Cited by

  1. Reliability-based design of semi-rigidly connected base-isolated buildings subjected to stochastic near-fault excitations vol.11, pp.4, 2016, https://doi.org/10.12989/eas.2016.11.4.701
  2. Seismic Fragility Estimates of LRB Base Isolated Frames Using Performance-Based Design vol.2017, 2017, https://doi.org/10.1155/2017/5184790
  3. Effects of ground motion frequency content on performance of isolated bridges with SSI vol.13, pp.4, 2017, https://doi.org/10.12989/eas.2017.13.4.353
  4. Effects of the isolation parameters on the seismic response of steel frames vol.15, pp.3, 2016, https://doi.org/10.12989/eas.2018.15.3.319
  5. Effect of dynamic soil-structure interaction on the seismic response of bridges with elastomeric bearings vol.20, pp.2, 2019, https://doi.org/10.1007/s42107-018-0098-0
  6. The effect of base isolation and tuned mass dampers on the seismic response of RC high-rise buildings considering soil-structure interaction vol.17, pp.4, 2016, https://doi.org/10.12989/eas.2019.17.4.425
  7. Seismic poundings of multi-story buildings isolated by TFPB against moat walls vol.20, pp.3, 2021, https://doi.org/10.12989/eas.2021.20.3.295