DOI QR코드

DOI QR Code

Comparison of the Heating/Cooling Energy Demand and Cost according to the Unit Position in a Passive House Apartment

패시브 공동주택 세대 위치별 에너지요구량에 따른 냉난방 에너지비용 비교 연구

  • Received : 2015.06.04
  • Accepted : 2015.11.13
  • Published : 2015.11.30

Abstract

We analyzed and compared the cooling/heating energy demand and cost of nine households of different positions in a passive house Apartment. To do this, the Passive House Planning Package(PHPP) was used on Building 102 of the Net Zero Energy Housing Complex located in Hagye-dong, Nowon-gu, Seoul, Korea. For the heating energy demand, it was analyzed that the middle floor and the first floor have the lowest and highest demands, respectively, and the highest demand was about twice as the lowest. On the same floor, the units in the middle had the lowest demand, while the units on the right and left of the building had little difference. For the cooling energy demand, the higher floors had higher demand, and the highest cooling energy demand was about 40% higher than the lowest. There was not much difference between the units on the same floor when it comes to cooling energy. By analyzing the cooling and heating costs of each household, we concluded that the household with the highest electricity bills payed about 50% higher cost than the one with the lowest bills.

Keywords

Acknowledgement

Supported by : 국토교통부

References

  1. Asian Business newspaper. (2014). [The inspection of the administration conducted by National Assembly 2014] The apartment's management expense is corruption.
  2. Choi, H. & Han,S. (2013). Validation study of ISO 13790 monthly method for heating/cooling load-Intermittent and continuous operation, Journal of the Facility Institute of Korea, Summer of Conference, 431-434.
  3. Korea Electric Power Corporation. (2013). Electric price list.
  4. Lim, I. (2013). A Study on the correlation between actual value of green remodeling building and predicted value of energy simulations, Master's thesis, Myongji University graduate school.
  5. Lee, M. (2015). Analysis of the impact of floor area ratio on heating energy demand by passive housing complex, Journal of the Architectural Institute of Korea, Planning and Design Section, 31(5), 15-24.
  6. Lee, J. (2011). A Study on the effect of location conditions of apartment household on the heating energy consumption, Master's thesis, Kyungwon University graduate school.
  7. Ministry of Land, Infrastructure and Transport. (2014). Building energy performance improvement.
  8. Seoul City Hall, Green Energy Department. (2014). Seoul's electricity usage is decreased, 2014.
  9. The Meteorological Administration, Nowon-gu -AWS data, 2012-2013