• Title/Summary/Keyword: Passive Housing

Search Result 77, Processing Time 0.028 seconds

Analysis of Housing Cases with Passive Cooling Technologies - Based on LEED(Leadership in Energy and Environmental Design) housing cases in North America - (자연냉방기법 활용 주거 사례분석 연구 - 미국 LEED 인증 주택을 대상으로 -)

  • Yoon, Hea-Kyung;Woo, Seung-Hyun
    • Korean Institute of Interior Design Journal
    • /
    • v.18 no.6
    • /
    • pp.28-35
    • /
    • 2009
  • The purpose of this study is to analyze the state-of-the-art housing cases with passive cooling technologies and to explore the feasibilities for their applications in domestic housing design. Nineteen Leadership in Energy and Environmental Design housing cases from 2002 to 2007 were selected and analyzed their used passive cooling technologies. Besides traditional passive cooling technologies such as site planning according to the sun direction, the use of thermal mass, insulation, shading, below-ground spaces and ventilation, the relatively new technology trends were detected as followings; the use of high performance envelope, operable windows, and geo-thermal energy as the cooling source of heat pumps, increased areas of photovoltaic cells, and the education of the owner and tenants about the adopted passive cooling technologies in a building. Especially, the education may have not been focused in the domestic design despite of its effectiveness on the appropriate operations of passive cooling technologies. The results of this study show their positive adaptations would be beneficial to domestic housing design to reduce energy costs and have cooler housing environments in summer.

Housing Values and Satisfaction among University Students in Gwangju and the Chonnam Area (광주.전남지역 대학생의 주거가치와 주거 만족도)

  • Kim, Mi-Hee;Noh, Se-Hee
    • Journal of the Korean housing association
    • /
    • v.19 no.4
    • /
    • pp.11-20
    • /
    • 2008
  • The purpose of this study is to gather baseline data on perceived housing values and satisfaction rates among consumers with the aim of using this information for future planning. Self-administered questionnaires were provided to 1000 university students from Gwangju and the Chonnam area from 2007 October 8th to 30th. The collected data was used to conduct comparative and descriptive statistical analysis: factor analysis, cluster analysis, t-test, $x^2-test$ and one-way ANOVA. The main findings are as follows: Firstly, in relation to perceived house values, students identified three factors as important: pursuit of convenience, disposition toward individuality-orientation and consciousness of others. The respondents regarded convenience as very important, especially in regard to one's safety, health and location of amenities. Secondly, cluster analysis based on perceived house value revealed passive and energetic types. Students in the energetic type exhibited a tendency to prefer convenience, independence, and consciousness of others. Finally in terms of housing satisfaction, the respondents identified four factors as important: house quality, neighborhood environment, local socio-psychological environment, and location. Housing satisfaction was higher among students who lived in large or new houses, shared the same house with their family, and had a room all to themselves. Accoding to these findings, university students important value safety, health and environmental-friendliness in a house and they find location important. Therefore, future houses should reflect these wants.

Analytic Study on the Design Elements for Energy Conservative Green-Home Prototyping (에너지 저감형 그린홈 프로토타이핑을 위한 설계요소 분석 연구)

  • Kim, Jung-Eun;Chang, Seong-Ju;Ha, Mi-Kyoung;Sung, Hae-Yoen;Kim, Kyung-Wan
    • KIEAE Journal
    • /
    • v.11 no.4
    • /
    • pp.63-70
    • /
    • 2011
  • In respond to the global energy crisis and climate change, there have been many ongoing national efforts to develop a sustainable housing prototype followed by "2 million Green Home Project" in Korea. More than 50% of nation's population are currently living in apartment housing thus the country is seriously in need of developing green apartment prototype. In this research, we focused on energy-conservative green apartment design prototype that have both passive components and active systems explored in a systemic design approach. After selecting an existing basic apartment unit, we analyzed and compared statistical data with the simulated annual energy consumption to match these two data sets for validating simulation accuracy performed with TRNSYS package. We performed energy simulations with different passive design factors such as varied insulation thickness, window types and infiltration rates as well as the active design factors including boilers and lighting fixtures to analyze their impacts on the energy performance of the housing unit using TRNSYS software. As a result, we acquired significant energy reduction effect with explored design strategies but the life cycle cost analysis for the final design guidline would need to be performed. In this study, we focused on a systematic comparative energy analysis based on TRNSYS that can improve the design of a green apartment housing.

A Study on the Optimization of Photovoltaic System for the ZEB Certification in Detached Housing (단독 주택의 제로에너지건축물 인증을 위한 태양광시스템 최적화에 관한 연구)

  • Shin, Jee-Woong;Yun, Jae-Hyun;Ko, Jeong-Lim
    • Journal of the Korean Solar Energy Society
    • /
    • v.39 no.3
    • /
    • pp.1-7
    • /
    • 2019
  • As part of the government's energy policy, Zero Energy Building certification was launched on January of 2017. However, the three passive-housing rental housing projects are the only ZEB-certified detached housing since the certification's launch. The reason is that, in order for a detached housing to earn ZEB certification, it has to secure self-reliance in energy, and a photovoltaic system is the only viable renewable energy system. Therefore, conducting an analysis to optimize the photovoltaic system in an early design stage is strongly recommended. This study aimed to propose an optimal photovoltaic system design for a detached housing after analyzing through the ECO2 energy simulation of 44 cases, varying in a module type and efficiency, inclination and azimuth. As a result, 15 cases out of 44 cases were analyzed to satisfy ZEB evaluation criteria, and it is thought that these data could contribute greatly to the expansion of ZEB certification dissemination.

Types of Housing Lifestyle and Preference for Interior Design Image among Urban Female Residents (도시여성의 주생활양식유형과 실내디자인 이미지 선호)

  • 김미희;문희정
    • Journal of the Korean housing association
    • /
    • v.13 no.4
    • /
    • pp.43-52
    • /
    • 2002
  • This study explores the types of lifestyle of females living in urban areas, and examines the relationship between the types of lifestyle and the preference for interior design images. The research sample is 301 adult females in Kwangju City, Korea. The sample is divided into two groups by employment status. Based on eight lifestyles by related factors, four major lifestyle types are classified: traditional type, private and sensible type, passive and private type, and environment-oriented and sensible type. The portions of these types are 32.6% of passive and private type, 21.6% of environment-oriented and sensible one, 21.6% of active and sensible one, and 16.6% of traditional one. The research of the lifestyle types reveals that they differ by age, marital status, education, and dwelling types. There are negligible differences among four types in preference for three interior design images.

A Study on the Energy Saving Methods of a House by Passive System (건축적 수법을 통한 주택의 에너지 절약 방안에 관한 연구)

  • 김용식
    • Journal of the Korean housing association
    • /
    • v.13 no.2
    • /
    • pp.73-78
    • /
    • 2002
  • Recently, the energy consumption has been sharply increased and the environmental pollution has been serious, resulted in increased use of fossil fuel. These facts are applied to most fields, and are especially important issues in the field of architecture. The energy consumption rate of building is about 30% of all energy consumption, and the rate of residential is about 20% of the rate of building and is increasing gradually. The purpose of this article is firstly to analyse an actual energy consumption rate of model building and compare it with alternative methods, which are applied passive system to, and secondly to suggest an optimal passive method for saving energy. The conclusion of this study is as follows; 1) As compared with the existing house on actual energy consumption rate, 6% in changing orientation to a south, 9% in using double low-e glazing and 23% in shading is decreased. 2) The change of insulation from 50 to 100mm did not show dramatical difference in energy consumption rate. 3) As changed indoor temperature at 2$0^{\circ}C$ in winter and 27$^{\circ}C$ in summer, the rate shows a reduction of 14% compared with the existing condition.

Study of Design Strategy to Reduce Energy Consumption in a Standard Office Building (사무용 건물의 에너지 절감을 위한 요소별 성능 분석 및 디자인 전략에 관한 연구)

  • Yang, Ja-Kang;Kim, Chul-Ho;Kim, Kang-Soo
    • KIEAE Journal
    • /
    • v.16 no.2
    • /
    • pp.23-31
    • /
    • 2016
  • Purpose: Recently energy consumption is rapidly increasing due to continuous development of social evolution in various field. In this situation, there is a lot of effort to reduce this energy consumption in many ways, especially in building energy. Preceding studies already started to analyze the housing area such as zero energy house and passive house by researching annual building energy consumption, but to apply the results of housing to office building is insufficient since it has different consumption tendency. Method: In this study, eQuest program was used for simulation and the base model is selected among standard office building in ASHRAE 90.1. Variables are divided into passive and active factors for comparison. Result: In passive factors, glazing system showed the highest energy saving rate by 21.3% with triple low-e glass and enhancing wall u-value showed the lowest energy saving rate by 3.6% with 0.15 m2/K. In active factors, VAV system showed 30.9% energy saving rate when compared to CAV system, and heat exchanger showed 10.2% energy saving rate. For regeneration energy part, photovoltaic panel generated 10.4% of base annual energy usage.

A Study on the Community Space that Affect the Public Rental Housing Satisfaction Determinants (공공임대주택 단지만족도에 영향을 미치는 공동체공간 결정 요인에 관한 분석)

  • Park, Joon-Young;Jeong, Jae-Jin;Park, woo-Jang
    • KIEAE Journal
    • /
    • v.16 no.1
    • /
    • pp.95-101
    • /
    • 2016
  • This study aims to analyze the satisfaction targeted community space for public rental housing tenants a real community space. and community space is analyzed only through the factor analysis of the effects of satisfaction, multiple regression analysis etc. As a result, the space community and public rental housing will only affect the satisfaction, factors affecting such analysis was 'common space', 'exercise place', 'resting place'. Thus, a variety of political and institutional efforts and practical research for interactive spatial planning public rental housing estates satisfaction for the improvement and community activation moving away from passive concept of the one-way ever to supply that community space in the past, provider centers and considering the tenant characteristics is required.

Analysis of Environment-friendly Characteristics in the Environment - friendly Housing Certification (친환경 인증단지에 적용된 친환경적 계획특성 분석)

  • Lee, Song-Hyun;Hwang, Yeon-Sook
    • Proceeding of Spring/Autumn Annual Conference of KHA
    • /
    • 2005.11a
    • /
    • pp.181-184
    • /
    • 2005
  • The awareness of ecological friendliness has been emerging in the recent years, and the application to housing is quite notable. The purpose of this study is to evaluate environment-friendly planning factor in Environment-friendly Housing Certification. For this purpose, this study has analyzed 5 multi-family housing in Environment-friendly Housing Certification. The findings of this study are as follows: The application of environment-friendly planning factor in interior space are limited. Most of plans are located in south. The variability of floor plan is not applied but the built-in storage is well-applied. Environment-friendly finishing material and the garden-style balconies was applied in a passive way. This analysis showed current status of planning factor of unit apartment in Environment-friendly Housing Certification and proved basic information for future direction.

  • PDF

Perception on Housing Welfare of Social Welfare Practitioners (주거복지에 대한 사회복지업무 종사자의 의식조사 연구)

  • Kim, Young-Joo;Kim, Mi-Hee;Park, Nam-Hee
    • Journal of the Korean housing association
    • /
    • v.21 no.6
    • /
    • pp.119-129
    • /
    • 2010
  • The purpose of this study was to identify perception on housing welfare of social welfare practitioners. Specific research interest was focused on the area of housing welfare services and necessity, problems when execute housing welfare services, and activating strategy of housing welfare. For the research purpose, questionnaires were distributed to 537 people who work in the field of social welfare including social welfare officials in local government authorities and social workers at community welfare centers nationwide by mail and e-mail and 405 questionnaires were analyzed using SPSS 15.0 program. Respondents thought that the supply of public rental housing was the most important service to promote housing welfare. They also indicated the most serious problem was the lack of budget and housing welfare services and programs. As main reasons of local government's passive attitude toward housing welfare services and programs, respondents mentioned low interest level of housing welfare and lack of housing welfare education. Most of the respondents agreed the necessity of introducing the curricula related to housing welfare and expected to spread interest toward housing welfare in the field of social welfare.