- ANSI/ASHRAE Standard 62.1-2013: Ventilation for Acceptable Indoor Air Quality
- ANSI/ASHRAE/IES Standard 90.1-2010 : Energy Standard for Buildings Except Low-Rise Residential Buildings
- Conroy, C.L., & Mumma, S. A. (2001). Ceiling Radiant Cooling Panels as a Viable Distributed Parallel Sensible Cooling Technology Integrated with Dedicated Outdoor Air Systems. ASHRAE Transactions, 107, 578-585.
- Cho, J. K., & Moon J. H. (2015). Energy consumption characteristics of patent room HVAC systems for large hospital buildings in worldwide climate zones. Architectural institute of Korea, 31(3), 171-180.
- Deng, S. (2014). Energy Benefits of Different Dedicated Outdoor Air Systems Configurations in Various Climates, PhD Dissertation, University of Nebraska, 31.
- Hydeman, M., Gillespie K. L., & Dexter, A. L. (2002). Tools and Techniques to Calibrate Electric Chiller Component Models. ASHRAE Transactions, 108, 733-741.
- Jeff, J. J. (1982). Open cycle solid desiccant cooling component models and system simulation, Ph D. Dissertation, University of Winsconsin-Madison.
- Jeong, J. W., & Mumma, S. A. (2006). Designing a Dedicated Outdoor Air System with Ceiling Radiant Cooling Panels. ASHRAE Journal, 48(10), 56-66.
- Jeong, J. W., & Mumma, S. A. (2005). Practical thermal performace correlations for molecular sieve and silica gel loaded enthalpy wheels. Applied Thermal Engineering, 719-740.
- Jeong, J. W., Mumma, S. A., & Bahnfleth, W. P. (2003). Energy Conservation Benefits of a Dedicated Outdoor Air System with Parallel Sensible Cooling by Ceiling Radiant Panels. ASHRAE Transactions, 109, 627-636.
- Jeong, J. W., & Mumma, S. A. (2005). Field Experience Controlling a Dedicated Outdoor Air System. ASHRAE Transactions, 111, 433-442.
- Jeong, J. W. (2004). Simplified ceiling radiant cooling panel and enthalpy wheel models for dedicated outdoor air system design, PhD. Dissertation, University of Pennsylvania State.
- Kim, H. G., & Jeong, C. H. (2013). Evaluation of thermal comfort and Energy Performance for the Radiant floor cooling system with Dedicated Outdoor Air system in apartment building. Architectural institute of Korea, 29(11), 273-281.
- Kim, J. J., & Kwon, O. H. (2011). The Estination Model of Photovoltaic Array Area For Designing Energy Independent Dedicated Outdoor Air System. Architectural institute of Korea, 27(1), 237-244.
- Kwon, O. H., & Kim, M. H. (2010). Energy Saving Impact of Parallel cooling system in a DOAS for School Buildings. Architectural institute of Korea, 30(1), 443-444.
- Mumma, S. A., & Shank, K. M. (2001). Achieving Dry Outside Air in an Energy-Efficient Manner. ASHRAE Transactions, 107, 689-697.
- Mumma, S. A. (2007). Doas & Desiccants. Engineered Systems, 24(8), 37-49.
- Murphy, J. (2012). Total energy wheel control in a dedicated OA system. ASHRAE journal, 53(3), 46-58.
- Panaras, G., & Mathioulaskis, E. (2010). Experimental validation of a simplified approach for a desiccant wheel model. Energy and Buildings, 42, 1719-1725. https://doi.org/10.1016/j.enbuild.2010.05.006
- Redlich, C. A., Sparer, J., & Cullen, M. R. (1997). Sick-Building syndrone. Lancet, 349(9057), 1013-1016. https://doi.org/10.1016/S0140-6736(96)07220-0