DOI QR코드

DOI QR Code

A Study on Architecture Design of Output Module for SIL4 Safety Related System

SIL4 안전관련 시스템에 적합한 출력 모듈의 구조 설계에 대한 연구

  • 유등열 (광운대학교 일반대학원 제어계측공학과) ;
  • 황경환 (철도신호사업연구조합) ;
  • 이기서 (광운대학교 로봇학부)
  • Received : 2015.08.12
  • Accepted : 2015.10.23
  • Published : 2015.10.31

Abstract

This paper introduces the architecture of OUTPUT module that is suitable using in safety related system having SIL4 and proposes the quantitative target that is required for OUTPUT module. Especially, only output type that is made up Relay output signal and analog signal among various output ways is applied in output module that is a part of safety related system. The FMEA(Failure Modes and Effect Analysis), FTA(Fault Tree Analysis) are used as analysis method. As a result, it proposes to the architecture and failure frequency of the Output module that is used in SIL4 safety related system.

본 논문은 안전 무결성 레벨이 4(: Safety Integrity Level 4)인 안전 관련 시스템에 적합한 출력 모듈의 구조를 설계하였고, 설계된 출력 모듈에 요구되는 정량적 목표치의 수준을 제시하였다. 특히 다양한 출력 방식 중에서 릴레이 출력 신호와 아날로그 신호로 구성된 출력 모듈이 안전 기능을 수행하는 시스템의 구성 요소인 경우를 적용하였다. 분석 방법은 FMEA(: Failure Modes and Effect Analysis), FTA(: Fault Tree Analysis) 방식을 이용하였다. 그 결과로 철도 응용 규격인 IEC 62425의 요구사항을 준수하는 SIL4 안전 관련 시스템의 출력 모듈의 구조와 고장빈도인 정량적 목표치를 제시하였다.

Keywords

References

  1. IEC 62425, "Railway applications-Communication, signaling and processing systems - safety related electronic systems for signaling," IEC, Geneva, Switzerland, Sept. 2007.
  2. IEC 61508, "Functional safety of electrical/ electronic/ programmable electronic safety-related systems," IEC, Geneva, Switzerland, Apr. 2010.
  3. IEC 62061, "Safety of machinery-Functional safety of safety-related electrical, electronic and programmable electronic control systems," IEC, Geneva, Switzerland, Jan. 2005.
  4. IEC 61511-1, "Functional safety-safety instrumented systems for the process industry sector," IEC, Geneva, Switzerland, Jan. 2003.
  5. IEC 61025, "Fault tree analysis(FTA)," IEC, Geneva, Switzerland, Dec. 2006.
  6. K. Chung, "Diagnosis of power supply by analysis of chaotic nonlinear dynamics," J. of the Korea Institute of Electronic Communication Sciences, vol. 9, no. 7, 2014, pp. 753-759. https://doi.org/10.13067/JKIECS.2014.9.7.753
  7. H. Shin, "Development of constant current SMPS for LED Lighting," J. of the Korea Institute of Electronic Communication Sciences, vol. 10, no. 1, 2015, pp. 111-116. https://doi.org/10.13067/JKIECS.2015.10.1.111
  8. Y. Jeong, "A study on control of generators based on SMPS," J. of the Korea Institute of Electronic Communication Sciences, vol. 7, no. 1, 2012, pp. 107-115. https://doi.org/10.13067/JKIECS.2012.7.1.107
  9. H. Shin, "Design of LED Driving SMPS for Large Traffic Signal Lamp," J. of the Korea Institute of Electronic Communication Sciences, vol. 4, no. 2, 2009, pp. 123-129.
  10. Y. Chai, "Development of OPAMP in an A/D Converter for Pressure Measurement," J. of the Korea Institute of Electronic Communication Sciences, vol. 5, no. 4, 2010, pp. 435-442.
  11. Z. Jin, "A Study on Software Static Analysis Method on IEC 62279," J. of the Korea Institute of Electronic Communication Sciences, vol. 10, no. 4, 2015, pp. 513-520. https://doi.org/10.13067/JKIECS.2015.10.4.513
  12. H. Jung, "Study on Precise Positioning using Hybrid Track Circuit system in Metro," J. of the Korea Institute of Electronic Communication Sciences, vol. 8, no. 3, 2013, pp. 471-477. https://doi.org/10.13067/JKIECS.2013.8.3.471
  13. S. Ryou, "An Allocation of Safety Integrity Level to Inductive Loop type Train Control System," J. of the Korea Institute of Electronic Communication Sciences, vol. 8, no. 12, 2013, pp. 1905-1910. https://doi.org/10.13067/JKIECS.2013.8.11.1905
  14. IEC TR 62380, "Reliability data handbook -Universal model for reliability prediction of electronics components, PCBs and equipment," IEC, Geneva, Switzerland, 2004.