References
- Fazel R, Krumholz HM, Wang Y, Ross JS, Chen J, Ting HH, et al., "Exposure to Low-Dose Ionizing Radiation from Medical Imaging Procedures," N Engl J Med, vol. 361, no. 9, pp. 849-57, 2009. https://doi.org/10.1056/NEJMoa0901249
- Lin EC, "Radiation Risk From Medical Imaging," Mayo Clin Proc, vol. 85, no. 12, pp. 1142-1146, 2010. https://doi.org/10.4065/mcp.2010.0260
- American Academy of Pediatrics. Committee on Environmental Health, "Risk of ionizing radiation exposure to children: a subjective review," Pediatrics, vol. 101, no. 4, pp. 717-719, 1998. https://doi.org/10.1542/peds.101.4.717
- Goske MJ, Applegate KE, Boylan J, Butler PF, Callahan MJ, Coley BD, et al., "The 'Image Gently' campaign: increasing CT radiation dose awareness through a national education and awareness program," Pediatr Radiol, vol. 38, no. 3 pp. 265-269, 2008. https://doi.org/10.1007/s00247-007-0743-3
- Slomka PJ, Dey D, Duvall WL, Henzlova MJ, Berman DS, Germano G, "Advances in Nuclear Cardiac Instrumentation with a View Towards Reduced Radiation Exposure," Curr Cardiol Rep, vol. 14, no. 2, pp. 208-216, 2012. https://doi.org/10.1007/s11886-012-0248-z
- Mettler Jr FA, Huda W, Yoshizumi TT, Mahesh M, "Effective Doses in Radiology and Diagnostic Nuclear Medicine," Radiology, vol. 248, no. 1, pp. 254-263, 2008. https://doi.org/10.1148/radiol.2481071451
- Jafari ME, Daus AM, "Applying Image Gently SM and Image Wisely SM in nuclear medicine," Health Phys, vol. 104, no. 2, Suppl.1, pp. S31-S36, 2013. https://doi.org/10.1097/HP.0b013e3182764cd8
- Rao VM, Levin DC, "The Choosing Wisely Initiative of the American Board of Internal Medicine Foundation: What Will Its Impact Be on Radiology Practice?" AJR, vol. 202, no. 2, pp. 358-361, 2013.
- Dorbala S, Blankstein R, Skali H, Park M-A, Fantony J, Mauceri C, et al., "Approaches to Reducing Radiation Dose from Radionuclide Myocardial Perfusion Imaging," J Nucl Med, vol. 56, no. 4, pp. 592-599, 2015. https://doi.org/10.2967/jnumed.112.115097
- Miller TD, Askew JW, O'Connor MK, "New Toys for Nuclear Cardiologists," Circ Cardiovasc Imaging, vol. 4, no. 1, pp. 5-7, 2011. https://doi.org/10.1161/CIRCIMAGING.110.961987
- Robert C, Montemont G, Rebuffel V, Verger L, Buvat I, "Optimization of a parallel hole collimator/CdZnTe gammacamera architecture for scintimammography," Med Phys, vol. 38, no. 4, pp. 1806-1819, 2011. https://doi.org/10.1118/1.3560423
- Garcia EV, Faber TL, Esteves FP, "Cardiac Dedicated Ultrafast SPECT Cameras: New Designs and Clinical Implications" J Nucl Med, vol. 52, no. 2, pp. 210-217, 2011. https://doi.org/10.2967/jnumed.110.081323
- Oddstig J, Hedeer F, Jogi J, Carlsson M, Hindorf C, Engblom H, "Reduced administered activity, reduced acquisition time, and preserved image quality for the new CZT camera," J Nucl Cardiol, vol. 20, no. 1, pp. 38-44, 2013. https://doi.org/10.1007/s12350-012-9634-6
- Smith MF, "Recent Advances in Cardiac SPECT Instrumentation and System Design," Curr Cardiol Rep, vol. 15, no. 8, pp. 387-397, 2013. https://doi.org/10.1007/s11886-013-0387-x
- Bocher M, Blevis IM, Tsukerman L, Shrem Y, Kovalski G, Volokh L, "A fast cardiac gamma camera with dynamic SPECT capabilities: design, system validation and future potential," Eur J Nucl Med Mol Imaging, vol. 37, no. 10, pp. 1887-1902, 2010. https://doi.org/10.1007/s00259-010-1488-z
- Holbrook A, Newell MS, "Alternative Screening for Women With Dense Breasts: Breast-Specific Gamma Imaging (Molecular Breast Imaging)," AJR, vol. 204, no. 2, pp. 252-256, 2015. https://doi.org/10.2214/AJR.14.13525
- Sharir T, Slomka PJ, Berman DS, "Solid-State SPECT technology: fast and furious," J Nucl Cardiol, vol. 17, no. 5, pp. 890-896, 2010. https://doi.org/10.1007/s12350-010-9284-5
- kamada K, Yanagida T, Endo T, Tsutumi K, Usuki Y, Nikl M, et al., "2 inch diameter single crystal growth and scintillation properties of Ce:Gd3Al2Ga3O12," J Crystal Growth, vol. 352, pp. 88-90, 2012. https://doi.org/10.1016/j.jcrysgro.2011.11.085
- Fujita T, Kataoka J, Nishiyama T, Ohsuka S, Nakamura S, Yamamoto S, "Two-dimensional diced scintillator array for innovative, fine resolution gamma camera," Nucl Instr Meth Phys A, vol. 765, pp. 262-268, 2014. https://doi.org/10.1016/j.nima.2014.04.060
- Slomka PJ, Patton JA, Berman DS, Germano G, "Advances in technical aspects of myocardial perfusion SPECT imaging," J Nucl Cardiol, vol. 16, no. 2, pp. 255-276, 2009. https://doi.org/10.1007/s12350-009-9052-6
- Vandenberghe S, Asseler YD, Van de Walle R, Kauppinen T, Koole M, Bouwens L, et al., "Iterative reconstruction algorithms in nuclear medicine," Comput Med Imaging Graph, vol. 25, no. 2, pp. 105-111, 2001. https://doi.org/10.1016/S0895-6111(00)00060-4
- Madsen MT, "Recent Advances in SPECT Imaging," J Nucl Med, vol. 48, no. 4, pp. 661-673, 2007. https://doi.org/10.2967/jnumed.106.032680
- Borges-Neto S, Pagnanelli RA, Shaw LK, Honneycutt E, Schwartz SC, Adams GL, et al., "Clinical results of a novel Wide Beam Reconstruction method for shortening scan time of cardiac SPECT perfusion studies," J Nucl Cardiol, vol. 14, no. 4, pp. 555-565, 2007. https://doi.org/10.1016/j.nuclcard.2007.04.022
- Sheehy N, Tetrault TA, Zurakowski D, Vija AH, Fahey FH, Treves ST, "Pediatric 99mTc-DMSA SPECT Performed by Using Iterative Reconstruction with Isotropic Resolution Recovery: Improved Image Quality and Reduced Radiopharmaceutical Activity," Radiology, vol. 251, no. 2, pp. 511-516, 2009. https://doi.org/10.1148/radiol.2512081440
- Stansfield EC, Sheehy N, Zurakowski D, Vija AH, Fahey FH, Treves ST, "Pediatric 99mTc-MDP Bone SPECT with Ordered Subset Expectation Maximization Iterative Reconstruction with Isotropic 3D Resolution Recovery," Radiology, vol. 257, no. 3, pp. 793-801, 2010. https://doi.org/10.1148/radiol.10100102
- Venero CV, Heller GV, BatemanTM, McGhie A I, Ahlberg A W, Katten D, et al., "A multicenter evaluation of a new postprocessing method with depth-dependent collimator resolution applied to full-time and half-time acquisitions without and with simultaneously acquired attenuation correction," J Nucl Cardiol, vol. 16, no. 2, pp. 714-725, 2009. https://doi.org/10.1007/s12350-009-9106-9
- Borges-Neto S, Pagnanelli RA, Shaw LK, Honeycutt E, Shwartz SC, et al., "Clinical results of a novel wide beam reconstruction method for shortening scan time of Tc-99m cardiac SPECT perfusion studies," J Nucl Cardiol, vol. 14, no. 4, pp. 555-565, 2007. https://doi.org/10.1016/j.nuclcard.2007.04.022
- DePuey EG, Gadiraju R, Clark J, Thompson L, Anstett F, Shwartz SC, "Ordered subset expectation maximization and wide beam reconstruction 'half-time' gated myocardial perfusion SPECT functional imaging: a comparison to 'fulltime' filtered backprojection," J Nucl Cardiol, vol. 15, no. 4, pp. 547-563, 2008. https://doi.org/10.1016/j.nuclcard.2008.02.035
- DePuey EG, Bommireddipalli S, Clark J, Thompson L, Srour Y, "Wide beam reconstruction "quarter-time" gated myocardial perfusion SPECT functional imaging: a comparison to "full-time" ordered subset expectation maximum," J Nucl Cardiol, vol. 16, no. 5, pp. 736-752, 2009. https://doi.org/10.1007/s12350-009-9108-7
- Vija AH, Hawman EG, Engdahl JC, "Analysis of a SPECT OSEM Reconstruction Method with 3D Beam Modeling and Optional Attenuation Correction: Phantom Studies," Nucl Sci Symp Conf Rec, vol. 4, pp. 2662-2666, 2003.
- Takahashi Y, Miyagawa M, Nishiyama Y, Ishimura H, Mochizuki T, "Performance of a semiconductor SPECT system: comparison with a conventional Anger-type SPECT instrument," Ann Nucl Med, vol. 27, pp. 11-16, 2013. https://doi.org/10.1007/s12149-012-0653-9
- Takalo R, Hytti H, Ihalainen H, "Adaptive Autoregressive Model for Reduction of Poisson Noise in Scintigraphic Images," J Nucl Med Technol, vol. 39, no. 1, pp. 19-26, 2011. https://doi.org/10.2967/jnmt.110.077081
- Hsiao EM, Cao X, Zurakowski D, Zukotynski K, Drubach LA, Grant FD, "Reduction in Radiation Dose in Mercaptoacetyltriglycerine Renography with Enhanced Planar Processing," Radiology, vol. 261, no. 3, pp. 907-915, 2011 https://doi.org/10.1148/radiol.11110602
- Ogawa K, Sakata M, Li Y, "Adaptive Noise Reduction of Scintigrams with a Wavelet Transform," Int J Biomed Imaging, vol. 2012, 2012.
- Ardenfors O, Sandqvist P, Jacobsson H, Svanholm U, "Pixon-based noise reduction algorithm for shorter acquisition time in whole body scintigraphy," J Nucl Med, vol. 55, suppl.1, pp. 2128, 2014.
- Dey D, Slomka PJ, Berman DS, "Achieving Very-Low-Dose Radiation Exposure in Cardiac Computed Tomography, Single-Photon Emission Computed Tomography, and Positron Emission Tomography," Circ Cardiovasc Imaging, vol. 7, pp. 723-734, 2014. https://doi.org/10.1161/CIRCIMAGING.113.000897
- Duvall WL, Wijetunga MN, Klein TM, Razzouk L, Godbold J, Croft LB, et al., "The prognosis of a normal stress-only Tc-99m myocardial perfusion imaging study," J Nucl Cardiol, vol. 17, no. 3, pp. 370-377, 2010. https://doi.org/10.1007/s12350-010-9210-x
- Henzlova M, Duvall WL, "The future of SPECT MPI: Time and dose reduction," J Nucl Cardiol, vol. 18, no. 4, pp. 580-587, 2011. https://doi.org/10.1007/s12350-011-9401-0
- Mahmarian JJ, Chang S, Nabi F, "Nuclear cardiology: 2014 innovations and developments," Methodist Debakey Cardiovasc J, vol. 10, no. 3, pp. 163-171, 2014. https://doi.org/10.14797/mdcj-10-3-163
- Lee K, Bae S, Lee H, Kim Y, Min E, Kim Y-H, "Registered Collimation for Pixellated SPECT Detectors," in IEEE Nuclear Science Symposium Conference Record, Dresden, 2008, pp. 4954-4957.