References
- M.R. Miller, J. Hankinson, V. Brusasco, F. Burgos, R. Casaburi, A. Coates, R. Crapo, P. Enright, C.P.M. van der Grinten, P. Gustafsson, R. Jensen, D.C. Johnson, N. MacIntyre, R. McKay, D. Navajas, O.F. Pedersen, R. Pellegrino, G. Viegi and J. Wanger, "Standardization of spirometry", Eur Respir J, vol. 26, pp. 319-338, 2005. https://doi.org/10.1183/09031936.05.00034805
- A.D. Jr. Renzetti, "Standardization of spirometry", Am Rev Respir Dis, vol. 119, pp. 831-838, 1979.
- American Thoracic Society, "Standardization of spirometry: 1987 update", Am Rev Respir Dis, vol. 136, pp. 1285-1298, 1987. https://doi.org/10.1164/ajrccm/136.5.1285
- American Thoracic Society, "Standardization of spirometry, 1994 update", Am J Respir Crit Care Med, vol. 152, pp. 1107-1136, 1995. https://doi.org/10.1164/ajrccm.152.3.7663792
- P.H. Quanjer, ed. "Standardized lung function testing. Report Working Party Standardization of Lung Function Tests. European Community for Coal and Steel". Bull Eur Physiopathol Respir, vol. 19: Suppl.5, pp. 1-95, 1983.
- Official Statement of the European Respiratory Society, "Lung volume and forced ventilatory flows. Report Working Party Standardization of Lung Function Tests, European Community for Steel and Coal", Eur Respir J, vol. 6: Suppl.16, pp. 5-40, 1993. https://doi.org/10.1183/09041950.005s1693
- Ministry of Food and Drug Safety, "Performance evaluation guidelines for diagnostic spirometer", 2011.
- E. Schenaa, C. Massaronia, P. Saccomandia, S. Cecchinib, "Flow measurement in mechanical ventilation: A review", Medical Engineering & Physics, vol. 37, no. 3, pp. 257-264, 2015. https://doi.org/10.1016/j.medengphy.2015.01.010
- E. Russold, T.D. Ambrisko, J.P. Schramel, U. Auer, R. van Den Hoven, Y.P. Moens, "Measurement of tidal volume using respiratory ultrasonic plethysmography in anaesthetized, mechanically ventilated horses", Veterinary Anaesthesia and Analgesia, vol. 40, no. 1, pp. 48-54, 2013. https://doi.org/10.1111/j.1467-2995.2012.00751.x
- A.A. Mohammad, V.R. Nafisi1, F. Farhani, "Extrapolation of calibration curve of hot-wire spirometer using a novel neural network based approach", Journal of Medical Signals & Sensors, vol. 2, no. 4, pp. 185-191, 2012.
- K.A. Kim, T.S. Lee, E.J. Cha, "Unequal distance sampling technique to design velocity-type respiratory air flow transducer", J. Biomed. Eng. Res., vol. 25, no. 5, pp. 351-359, 2004.
- K.A. Kim, T.S. Lee, E.J. Cha, "Design Criteria to Miniaturize the Single Use Functional Respiratory Air Flow Tube", J. Biomed. Eng. Res., vol. 26, no. 3, pp. 163-169, 2005.
- W.J. Yoo, J.Y. Baek, D.H. Cho, K.W. Jang, J.K. Seo, J.Y. Heo, B.S. Lee, Y.H. Cho, B.G. Park, J.H. Moon, "Development of a respiration sensor using plastic optical fiber", J. Biomed. Eng. Res., vol. 30, no. 6, pp. 489-494, 2009.
- K.A. Kim, I.K. Lee, J.O. Park, S.O, Lee, E.Y. Shin, Y.K Kim, K.C. Kim, E.J. Cha, "Respiratory air flow transducer based on air turbulence", J. Biomed. Eng. Res., vol. 30, no. 5, pp. 393-400, 2009.
- D.W. Kim, D.S. Yeon, S.C. Kim, "Development of respiratory monitoring system by inductive plethysmography", J. Biomed. Eng. Res., vol. 16, no. 3, pp. 353-358, 1995.
- Chungbuk National Univ. Industry-University Cooperation Foundation, "Calibration and performance verification device for diagnostic spirometer", Korea, Patent No. 10-1533887, 2015.
- B.G. Jeon, Y.G. Kang, K.A. Kim, T.S. Lee, E.J. Cha, "Volume accuracy of the servo-motor driven standard air flow generator system", Journal of Korea Intellectual Patent Society, vol. 7, no. 1, pp. 79-82, 2005.