DOI QR코드

DOI QR Code

가속도계를 이용한 진전현상의 분석을 통한 파킨슨병과 본태성 진전의 판별

Discrimination of Parkinson's Disease from Essential Tremor using Acceleration based Tremor Analysis

  • 이홍지 (서울대학교 공과대학 협동과정 바이오엔지니어링 전공) ;
  • 이웅우 (을지병원 신경과) ;
  • 전효선 (서울대학교 공과대학 협동과정 바이오엔지니어링 전공) ;
  • 김상경 (서울대학교 공과대학 협동과정 바이오엔지니어링 전공) ;
  • 김한별 (서울대학교 공과대학 협동과정 바이오엔지니어링 전공) ;
  • 전범석 (서울대학교병원 신경과) ;
  • 박광석 (서울대학교 의과대학 의공학교실)
  • Lee, Hongji (Interdisciplinary Program for Bioengineering, Seoul National University) ;
  • Lee, Woongwoo (Department of Neurology, Eulji General Hospital) ;
  • Jeon, Hyoseon (Interdisciplinary Program for Bioengineering, Seoul National University) ;
  • Kim, Sangkyong (Interdisciplinary Program for Bioengineering, Seoul National University) ;
  • Kim, Hanbyul (Interdisciplinary Program for Bioengineering, Seoul National University) ;
  • Jeon, Beom S. (Department of Neurology, Seoul National University Hospital) ;
  • Park, Kwangsuk (Department of Biomedical Engineering, College of Medicine, Seoul National University)
  • 투고 : 2015.07.17
  • 심사 : 2015.08.25
  • 발행 : 2015.08.30

초록

Discrimination of Parkinson's disease (PD) from Essential tremor (ET) is often misdiagnosed in clinical practice. Since tremor is time-varying signal, and dominant and harmonic frequencies are shown in tremor only with moderate or severe symptom, there are some limitations to use frequency related features. Moreover, patients with PD or ET can suffer from both resting tremor and postural tremor. In this study, 28 patients with PD and 17 patients with ET were enrolled. Tremor was measured with accelerations on the more affected hand during resting and postural conditions. The ratio of root mean square (RMS) of resting tremor to RMS of postural tremor, the mean coefficients of autocorrelation function (ACF), and the mean of differences of two adjacent coefficients of ACF at resting and postural were calculated and compared between PD and ET. The performance showed 98% accuracy with support vector machine and leave-one-out cross validation. In addition, the method accurately differentiated the patients with tremor-dominant PD from patients with ET, with 100% accuracy. Therefore, the developed algorithm can assist clinicians in diagnosing and categorizing patients with tremor, especially, patients with mild symptom or the early stage of a disease, for proper treatment.

키워드

참고문헌

  1. G. Deuschl, J. Raethjen, R. Baron, M. Lindemann, H. Wilms, and P. Krack, "The pathophysiology of parkinsonian tremor: a review," J. Neurol., vol. 247, pp. V/33-48, 2000. https://doi.org/10.1007/PL00007781
  2. S. Jain, S.E. Lo, and E.D. Louis, "Common misdiagnosis of a common neurological disorder: how are we misdiagnosing essential tremor?," Arch. Neurol., vol. 63, pp. 1100-1104, 2006. https://doi.org/10.1001/archneur.63.8.1100
  3. M. Engin, S. Demirag, E.Z. Engin, G. Celebi, F. Ersan, E. Asena, and Z. Colakoglu, "The classification of human tremor signals using artificial neural network," Expert Syst. Appl., vol. 33, pp. 754-761, 2007. https://doi.org/10.1016/j.eswa.2006.06.014
  4. A. Hossen, M. Muthuraman, J. Raethjen, G. Deuschl, and U. Heute, "Discrimination of Parkinsonian tremor from essential tremor by implementation of a wavelet-based soft-decision technique on EMG and accelerometer signals," Biomed. Signal Process. Control, vol. 5, pp. 181-188, 2010. https://doi.org/10.1016/j.bspc.2010.02.005
  5. M. Muthuraman, A. Hossen, U. Heute, G. Deuschl, and J. Raethjen, "A new diagnostic test to distinguish tremulous Parkinson's disease from advanced essential tremor," Mov. Disord., vol. 26, pp. 1548-1552, 2011. https://doi.org/10.1002/mds.23672
  6. D.J. Wile, R. Ranawaya, and Z.H.T. Kiss, "Smart watch accelerometry for analysis and diagnosis of tremor," J. Neurosci. Methods, vol. 230, pp. 1-4, 2014. https://doi.org/10.1016/j.jneumeth.2014.04.021
  7. L. Ai, J. Wang, and R. Yao, "Classification of parkinsonian and essential tremor using empirical mode decomposition and support vector machine," Digit. Signal Process., vol. 21, pp. 543-550, 2011. https://doi.org/10.1016/j.dsp.2011.01.010
  8. G. Deuschl, M. Lauk, and J. Timmer, "Tremor classification and tremor time series analysis," Chaos, vol. 5, pp. 48-51, 1995. https://doi.org/10.1063/1.166084
  9. P.M. Aubin, A. Serackis, and J. Griskevicius, "Support vector machine classification of Parkinson's disease, essential tremor and healthy control subjects based on upper extremity motion," In Proc. 1st International Conference on Biomedical Engineering and Biotechnology(iCBEB), Macau, Macao, May 2012, pp. 900-904.
  10. B. Hellwig, P. Mund, B. Schelter, B. Guschlbauer, J. Timmer, and C.H. Lucking, "A longitudinal study of tremor frequencies in Parkinson's disease and essential tremor," J. Clin. Neurophysiol., vol. 120, no. 2, pp. 431-435, 2009. https://doi.org/10.1016/j.clinph.2008.11.002
  11. G. Deuschl, P. Krack, M. Lauk, and J. Timmer, "Clinical neurophysiology of tremor," J. Clin. Neurophysiol., vol. 13, pp. 110-121, 1996. https://doi.org/10.1097/00004691-199603000-00002
  12. G. Deuschl, P.G. Bain, and M. Brin, "Consensus statement of the movement disorder society on tremor," Mov. Disord., vol. 13, pp. 2-23, 1998. https://doi.org/10.1002/mds.870130104
  13. O. Cohen, S. Pullman, E. Jurewicz, D. Watner, and E.D. Louis, "Rest tremor in patients with essential tremor: prevalence, clinical correlates, and electrophysiologic characteristics," Arch. Neurol., vol. 60, pp. 405-410, 2003. https://doi.org/10.1001/archneur.60.3.405
  14. E.D. Louis, N. Asabere, A. Agnew, C.B. Moskowitz, A. Lawton, E. Cortes, P.L. Faust, and J.P.G. Vonsattel, "Rest tremor in advanced essential tremor: a post-mortem study of nine cases," J. Neurol. Neurosurg. Psychiatry, vol. 82, no. 3, pp. 261-265, 2011. https://doi.org/10.1136/jnnp.2010.215681
  15. S. Ribaric and J. Rozman, "Sensors for measurement of tremor type joint movements," Informacije MIDEM, vol. 37, no. 2, pp. 98-104, 2007.
  16. J. Timmer, C. Gantert, G. Deuschl, and J. Honerkamp, "Characteristics of hand tremor time series," Biol. Cybern., vol. 70, pp. 75-80, 1993. https://doi.org/10.1007/BF00202568
  17. J. Sim and C.C. Wright, "The kappa statistic in reliability studies: use, interpretation, and sample size requirements," Phys. Ther., vol. 85, pp. 257-268, 2005.