DOI QR코드

DOI QR Code

뇌전증 경련 억제를 위한 실시간 폐루프 신경 자극 시스템 설계

Development of Real-time Closed-loop Neurostimulation System for Epileptic Seizure Suppression

  • 김소원 (이화여자대학교 전자공학과) ;
  • 김선희 (이화여자대학교 전자공학과) ;
  • 이예나 (이화여자대학교 전자공학과) ;
  • 황서영 (이화여자대학교 전자공학과) ;
  • 강태경 (이화여자대학교 전자공학과) ;
  • 전상범 (이화여자대학교 전자공학과) ;
  • 이향운 (이화여자대학교 의과대학 신경과) ;
  • 이승준 (이화여자대학교 전자공학과)
  • Kim, Sowon (Department of Electronics Engineering, Ewha Womans University) ;
  • Kim, Sunhee (Department of Electronics Engineering, Ewha Womans University) ;
  • Lee, Yena (Department of Electronics Engineering, Ewha Womans University) ;
  • Hwang, Seoyoung (Department of Electronics Engineering, Ewha Womans University) ;
  • Kang, Taekyeong (Department of Electronics Engineering, Ewha Womans University) ;
  • Jun, Sang Beom (Department of Electronics Engineering, Ewha Womans University) ;
  • Lee, Hyang Woon (Department of Neurology, Ewha Medical Center, Ewha Womans University) ;
  • Lee, Seungjun (Department of Electronics Engineering, Ewha Womans University)
  • 투고 : 2015.07.13
  • 심사 : 2015.08.23
  • 발행 : 2015.08.30

초록

Epilepsy is a chronic neurological disease which produces repeated seizures. Over 30% of epileptic patients cannot be treated with anti-epileptic drugs, and surgical resection may cause loss of brain functions. Seizure suppression by electrical stimulation is currently being investigated as a new treatment method as clinical evidence has shown that electrical stimulation to brain could suppress seizure activity. In this paper, design of a real-time closed-loop neurostimulation system for epileptic seizure suppression is presented. The system records neural signals, detects seizures and delivers electrical stimulation. The system consists of a 6-channel electrode, front-end amplifiers, a data acquisition board by National Instruments, and a neurostimulator and Generic Osorio-Frei algorithm was applied for seizure detection. The algorithm was verified through simulation using electroencephalogram data, and the operation of whole system was verified through simulation and in- vivo test.

키워드

참고문헌

  1. S.K. Lee, "Antiepileptic Drugs." J. Korean Med. Assoc., vol. 50, no. 7, pp. 645-651, 2007. https://doi.org/10.5124/jkma.2007.50.7.645
  2. Y.M. Shon, "Deep Brain Stimulation for the Treatment of Medically Intractable Epilepsy: A Review on Clinical Application." J. Korean Epilepsy Society, vol. 16, no. 1, pp. 9-13, 2012.
  3. M.T. Salam, D.K. Nguyen and M. Sawan, "A Low-power Implantable Device for Epileptic Seizure Detection and Neeurostimaulation." 2010 Biomedical Circuits and Systems Conference(BioCAS), Paphos, Nov. 2010, pp. 154-157.
  4. X. Liu, H. Hao, L. Yang, L. Li, J. Zhang, A. Yang and Y. Ma, "Epileptic Seizure Detection With the Local Field Potential of Anterior Thalamic of Rats Aiming at Real Time Application." 33rd Annual International Conference of the IEEE EMBS, Boston, Massachusetts USA, Aug. 2011, pp. 6781-6784
  5. I. Osorio, M.G. Frei and S.B. Wilkinson, "Real-Time Automated Detection and Quantitative Analysis of Seizures and Short-Term Prediction of Clinical Onset." Epilepsia, vol. 39, no. 6, pp. 615-627, 1998. https://doi.org/10.1111/j.1528-1157.1998.tb01430.x
  6. S.Y. Hwang, Y.N. Lee, S.E. Lee, S.W. Shin, S.J. Kim, H.W. Lee and S.B. Jun, "Low Cost Multilayered Depth-type Neural Probe Based on Liquid Crystal Polymer." World Congress 2012 on Medical Physics and Biomedical Engineering, Beijing, China, May 2012.
  7. S. Raghunathan, S.K. Gupta, H.S. Markandeya, K. Roy, and P.P. Irazoqui, "A Hardware-algorithm Co-design Approach to Optimize Seizure Detection Algorithms for Implantable Applications." J. Neurosci Methods, vol. 193, pp. 106-117, 2010. https://doi.org/10.1016/j.jneumeth.2010.08.008
  8. C.C. Jouny and G.K. Bergey, "Characterization of Early Partial Seizure Onset: Frequency, Complexity and Entropy." Clin. Neurophysiol., vol. 123, pp. 658-669, 2012. https://doi.org/10.1016/j.clinph.2011.08.003
  9. T. Kang, J. Yeom, J. Kim, H. Yoo, S. Lee, Y. Lee, S. Hwang, K. Eom, J. Park, H. Kim, S. Kim, S. Jun, "Wireless Controlled Fully Implantable Neural Stimulation System Using Zigbee Protocol." The Korea Society of Medical & Biological Engineering, Nov. 2012, pp. 375-377.
  10. H. Miranda, V. Gilja, C.A. Chestek, K.V. Shenoy and T.H. Meng, "HermesD: A High-Rate Long-Range Wireless Transmission System for Simultaneous Multichannel Neural Recording Applications." IEEE Trans. Biomed. Circuits Syst., vol. 4, no. 3, pp. 181-191, 2010. https://doi.org/10.1109/TBCAS.2010.2044573
  11. L. Liu, L. Yao, X. Zou, W.L. Goh and M.K. Je, "Neural Recording Front-End IC Using Action Potential Detection and Analog Buffer with Digital Delay for Data Compression", 35th Annual International Conference of the IEEE EMBS, Osaka, Japan, July 2013, pp. 747-750.
  12. C.Y. Wu, W.M. Chen and L.T. Kuo, "A CMOS Power-Efcient Low-Noise Current-Mode Front-End Amplier for Neural Signal Recording", IEEE Trans. Biomed. Circuits Syst., vol. 7, no. 2, pp. 107-114, 2013. https://doi.org/10.1109/TBCAS.2013.2256422