Abstract

The purpose of this study is to develop high performance of exterior insulation precast concrete wall and evaluate performance of the wall for the basic, production, construction and energy. The result of this study as follows : 1) High performance exterior insulation precast concrete wall was developed that the insulation performance is 40% higher and the weight is 50% less than existed RC-Wall. 2) The basic performance of PC-Wall was allowable in ASTM and AAMA standards. 3) The production performance was secured as manufacturing production system and mass production would be able. The construction was taken about 40 minutes for each PC-Wall. 4) In comparison with interior insulation system, linear thermal transmittance and annual heating energy demand of exterior PC-Wall apartment were decreased 18.4~82.5% and 17.6% respectively.

Keywords

Acknowledgement

Supported by : 국토교통부

References

  1. ASHRAE, A. H. F., & Book, D. (1997). American Society of Heating. Refrigeration and Air Conditioning Engineers.
  2. Astm, E. (2004). E283-04 Standard Method for Determining Rate of Air Leakage Through Exterior Windows, Curtain Walls, and Doors Under Specified Pressure Differences Across the Specimen. Annual Book of Astm Standards.
  3. Astm, E. (2002). E330-02 Standard Test Method for Structural Performance of Exterior Windows, Doors, Skylights and Curtain Walls by Uniform Static Air Pressure Difference. Annual Book of Astm Standards.
  4. Astm, E. (2009). E331-00 Standard Test Method for Water Penetration of Exterior Windows, Skylights, Doors, and Curtain Walls by Uniform Static Air Pressure Difference. Annual Book of Astm Standards.
  5. American Architectural Manufacturers Association. (2005). AAMA 501.1-05 Standard Test Method for Water Penetration of Windows, Curtain Walls and Doors Using Dynamic Pressure.
  6. American Architectural Manufacturers Association. (2003). AAMA 501.4-09 Recommended Static Testing Method for Evaluating Curtain Wall and Storefront Systems Subjected to Seismic and Wind Induced Interstory Drift.
  7. Gang, C. (2003). A Study on the Construction Cases of Exterior Insulation and Finish System(EIFS) and its Implications, Thesis, Chonbuk National University, 69
  8. ISO, B. (1997). 6946 Building Components and Building Elements-Thermal Resistance and Thermal Transmittance-Calculation Method..
  9. ISO, E. (2008). 13790 Energy Performance of Buildings-Calculation of Energy Use for Space Heating and Cooling.
  10. Lee, B. (2012). An Study on Method for Pre-assuring of Quality of External Insulation Installation Task by Introducing Image Processing, Thesis, Hanyang University, 4
  11. Lee, C., & Oh, S. (2004). An Experiment of the Flexible Apartment Housing by Flat-Plate System. Journal of The Korean Housing Association Conference, 2, 147-152
  12. Lee, S., Kim, M., Choi, J., Lee, Y.,& Jung, M. (2015). Evaluation for Applicability of Exterior Insulation Precast Concrete Wall. 2015 Journal of Architectural Institute of Korea Spring Conference, 35(1), 251-252
  13. Seok, H., Kwak, H., Jung, J., & Song, S. (2005). A Study on the Construction of Exterior Insulation and Finish System and its Implications. Journal of Architectural Institute of Korea, Planning and Design Section, 21(10), 255-264
  14. Song, S., Koo, B., & Lim, J. (2010). Comparison of Annual Heating and Cooling Energy Demands of Internally and Externally Insulated Apartment Buildings Considering the Thermal Bridging Effect and the Heat Capacity Difference Using Monthly Calculation Method of ISO 13790, Journal of Architectural Institute of Korea, Planning and Design Section, 26(7), 321-332
  15. Yun, Y., Jung, M., Lee, Y., Choi, J., & Lee, W. (2013). The Study on Evaluating the Heat Transfer Performance and Developing of High-Performance Precast Concrete Wall System. Korean Institute of Architectural Sustainable Environment and Building Systems, 7(3), 161-167