Dynamic properties of a building with viscous dampers in non-proportional arrangement

  • Suarez, Luis E. (Department of Civil Engineering and Surveying, University of Puerto Rico at Mayaguez) ;
  • Gaviria, Carlos A. (Department of Civil Engineering and Surveying, University of Puerto Rico at Mayaguez)
  • 투고 : 2015.01.01
  • 심사 : 2015.09.15
  • 발행 : 2015.09.25

초록

Any rational approach to define the configuration and size of viscous fluid dampers in a structure should be based on the dynamic properties of the system with the dampers. In this paper we propose an alternative representation of the complex eigenvalues of multi degree of freedom systems with dampers to calculate new equivalent natural frequencies. Analytical expressions for the dynamic properties of a two-story building model with a linear viscous damper in the first floor (i.e. with a non-proportional damping matrix) are derived. The formulas permit to obtain the equivalent damping ratios and equivalent natural frequencies for all the modes as a function of the mass, stiffness and damping coefficient for underdamped and overdamped systems. It is shown that the commonly used formula to define the equivalent natural frequency is not applicable for this type of system and for others where the damping matrix is not proportional to the mass matrix, stiffness matrix or both. Moreover, the new expressions for the equivalent natural frequencies expose a novel phenomenon; the use of viscous fluid dampers can modify the vibration frequencies of the structure. The significance of the new equivalent natural frequencies is expounded by means of a simulated free vibration test. The proposed approach may offer a new perspective to study the effect of viscous dampers on the dynamic properties of a structure.

키워드

참고문헌

  1. Adhikari, S. (2011), "An iterative approach for nonproportionally damped systems", Mech. Res. Commun., 38(3), 226-230. https://doi.org/10.1016/j.mechrescom.2011.02.009
  2. Antsaklis, P.J. and Michel, A.N. (2007), Linear Systems, Birkhauser Boston, New York, NY, US.
  3. ASCE 7-05 (2006), Minimum Design Loads for Buildings and Other Structures, ASCE, Reston, Virginia.
  4. Constantinou, M.C. and Symans, M.D. (1993), "Experimental study of seismic response of buildings with supplemental fluid dampers", Struct. Des. Tall Build., 2(2), 93-132. https://doi.org/10.1002/tal.4320020203
  5. Charney, F. and McNamara, R. (2008), "Comparison of methods for computing equivalent viscous damping ratios of structures with added viscous damping", J. Struct. Eng., 134(1), 32-44. https://doi.org/10.1061/(ASCE)0733-9445(2008)134:1(32)
  6. Cheng, F.Y., Jiang, H. and Lou, K. (2010), Smart Structures: Innovative Systems for Seismic Response Control, CRC Press, Boca Raton, Florida, US.
  7. Chu, Y.L., Song, J. and Lee, G.C. (2008), "Modal analysis of arbitrarily damped three-dimensional linear structures subjected to seismic excitations", Technical Report MCEER-09-0001, SUNY, Buffalo, NY.
  8. FEMA 450 (2004), Recommended Provisions for Seismic Regulations for New Buildings and Other Structures, Federal Emergency Management Agency, Washington DC.
  9. Gaviria, C.A. and Montejo, L.A. (2015a), "Optimal wavelet parameters for system identification", Mech. Syst. Signal Pr.. (under Review)
  10. Gaviria, C.A. and Montejo, L.A. (2015b), "Output-only identification of modal and physical properties using free vibration response", Earthq. Eng. Eng. Vib. (in Press)
  11. Humar, J.L. (2012), Dynamics of Structures, Taylor & Francis Group, London, UK.
  12. Jacobson, N. (2012), Basic Algebra I, Dover Publications, Mineola, NY, US.
  13. Krenk, S. (2005), "Frequency analysis of the tuned mass damper", J. Appl. Mech., 72(6), 936-942. https://doi.org/10.1115/1.2062867
  14. Lee, D. and Taylor, D.P. (2001), "Viscous damper development and future trends", Struct. Des. Tall Build., 10(5), 311-320. https://doi.org/10.1002/tal.188
  15. Lewandowski, R. (2008), "Optimization of the location and damping constants of viscous dampers", Ninth International Conference on Computational Structures Technology, Athens, September.
  16. Lewandowski, R., Bartkowiak, A. and Maciejewski, H. (2012), "Dynamic analysis of frames with viscoelastic dampers: a comparison of damper models", Struct. Eng. Mech., 41(1), 113-137. https://doi.org/10.12989/sem.2012.41.1.113
  17. Lewandowski, R. and Pawlak, Z. (2011), "Dynamic analysis of frames with viscoelastic dampers modelled by rheological models with fractional derivatives", J. Sound Vib., 330(5), 923-936. https://doi.org/10.1016/j.jsv.2010.09.017
  18. Lin, J.L., Bui, M.T. and Tsai, K.C. (2013), "An Energy-based approach to the generalized optimal locations of viscous dampers in two-way asymmetrical buildings", Earthq. Spectra, 30(2), 867-889. https://doi.org/10.1193/052312EQS196M
  19. Ma, F., Imam, A. and Morzfeld, M. (2009), "The decoupling of damped linear systems in oscillatory free vibration", J. Sound Vib., 324(1-2), 408-428. https://doi.org/10.1016/j.jsv.2009.02.005
  20. Ma, F., Morzfeld, M. and Imam, A. (2010), "The decoupling of damped linear systems in free or forced vibration". J. Sound Vib., 329(15), 3182-3202. https://doi.org/10.1016/j.jsv.2010.02.017
  21. Matlab-7.14 (2012), The MathWorks, Inc, Natick, Massachusetts.
  22. Mayes, R.L. and Naguib, W.I. (2005), "Comparative seismic performance of four structural systems and assessment of recent AISC BRB test requirements", 74th Annual Convention of Structural Engineers Association of California, San Diego, California.
  23. Miyamoto, H., Determan, L., Gilani, A. and Hanson, R. (2003), "Seismic rehabilitation of historic concrete structure with fluid viscoelastic dampers", 72nd Annual Structural Engineers Association of California Convention, Sacramento, September.
  24. Miyamoto, H.K. and Gilani, A. (2008), "Design of a new steel-framed building using ASCE 7 damper provisions", ASCE Structures Congress, Vancouver, April.
  25. Morzfeld, M., Ajavakom, N. and Ma, F. (2009), "Diagonal dominance of damping and the decoupling approximation in linear vibratory systems", J. Sound Vib., 320(1-2), 406-420. https://doi.org/10.1016/j.jsv.2008.07.025
  26. NGA database (2006), Next Generation Attenuation of Ground Motions. Pacific Earthquake Engineering Research Center, University of California, Berkeley.
  27. Occhiuzzi, A. (2009), "Additional viscous dampers for civil structures: Analysis of design methods based on effective evaluation of modal damping ratios", Eng. Struct., 31(5), 1093-1101. https://doi.org/10.1016/j.engstruct.2009.01.006
  28. Pawlak, Z. and Lewandowski R. (2013), "The continuation method for the eigenvalue problem of structures with viscoelastic dampers", Comput. Struct., 125, 53-61. https://doi.org/10.1016/j.compstruc.2013.04.021
  29. Pawlak, Z. and Lewandowski, R. (2014), "The qualitative differences in dynamic characteristics of structures with classical and fractional dampers", Proceedings of the Twelfth International Conference on Computational Structures Technology, Stirlingshire, Scotland.
  30. Pettinga, J., Oliver, S. and Kelly, T. (2013), "A design office approach to supplemental damping using fluid viscous dampers", Steel Innovations Conference, Christchurch, New Zealand, February.
  31. Pierson, H., Brevick, J. and Hubbard, K. (2013), "The effect of discrete viscous damping on the transverse vibration of beams", J. Sound Vib., 332(18), 4045-4053. https://doi.org/10.1016/j.jsv.2013.03.012
  32. Soong, T.T. and Dargush, G.F. (1997), Passive Energy Dissipation Systems in Structural Engineering, John Wiley & Sons Ltd, Baffins Lane Chichester, UK.
  33. Suarez, L.E. and Gaviria, C.A. (2014) "Equivalent frequencies and damping ratios of buildings with viscous fluid dampers: A closed form formulation", 10th US National Conference on Earthquake Engineering, Anchorage, Alaska.
  34. Symans, M., Charney, F., Whittaker, A., Constantinou, M., Kircher, C., Johnson, M. and McNamara, R. (2008), "Energy dissipation systems for seismic applications: Current practice and recent developments", J. Struct. Eng., 134(1), 3-21. https://doi.org/10.1061/(ASCE)0733-9445(2008)134:1(3)
  35. Trombetti, T. and Silvestri, S. (2006), "On the modal damping ratios of shear-type structures equipped with Rayleigh damping systems", J. Sound Vib., 292(1-2), 21-58. https://doi.org/10.1016/j.jsv.2005.07.023
  36. Trombetti, T. and Silvestri, S. (2007), "Novel schemes for inserting seismic dampers in shear-type systems based upon the mass proportional component of the Rayleigh damping matrix", J. Sound Vib., 302(3), 486-526. https://doi.org/10.1016/j.jsv.2006.11.030
  37. Whittle, J., Williams, M., Karavasilis, T.L. and Blakeborough, A. (2012), "A comparison of viscous damper placement methods for improving seismic building design", J. Earthq. Eng., 16(4), 540-560. https://doi.org/10.1080/13632469.2011.653864
  38. Wolfram Mathematica 9.0 (2012), Wolfram Research Inc, Champaign, Illinois, USA.

피인용 문헌

  1. Structural safety redundancy-based design method for structure with viscous dampers vol.59, pp.5, 2016, https://doi.org/10.12989/sem.2016.59.5.821
  2. Dynamic visco-hyperelastic behavior of elastomeric hollow cylinder by developing a constitutive equation vol.59, pp.4, 2016, https://doi.org/10.12989/sem.2016.59.4.601
  3. Generalized complex mode superposition approach for non-classically damped systems vol.73, pp.3, 2015, https://doi.org/10.12989/sem.2020.73.3.271