DOI QR코드

DOI QR Code

Diagnostic Usefulness of Quantitative Sensory Test Comparison with Photoplethysmography

광용적맥파와 정량적 감각검사의 비교를 통한 진단적 유용성

  • 이상봉 ((재)원주의료기기테크노밸리) ;
  • 서정혁 ((재)원주의료기기테크노밸리)
  • Received : 2015.07.20
  • Accepted : 2014.08.25
  • Published : 2015.06.30

Abstract

The purposes of this study were to compare the sensitivities of two tests, QST(quantitative sensory test)and PPG(photoplethysmography) in normal adults. We evaluated the sensory thresholds of QST and PPG and diabetes mellitus test in 17 normal adults. The finding of this study can be summarized as follow :The diagnostic sensitivities of QST was similar to PPG. There is a direct correlation between the amount of Blood sugar and parasympathetic nerve in ANS. Concluded that the QST might be complement to NCS for early of diabetic polyneuropathy. A new diagnostic approach, QST was introduced and exploited for diagnosis. This study provides support for PPG performed a ANS analysis.

본 논문의 목적은 당뇨병 및 신경병증의 병력이 없는 17명의 일반 성인을 대상으로 한 정량적 감각검사(QST)와 광용적맥파(PPG)와의 비교를 통해 정량적 감각검사의 임상적 유용성을 파악하는 것이며, 광용적맥파 검사를 이용한 혈당수치에 따른 자율신경계의 부교감신경의 변화를 살펴보는 것이다. 일반인을 대상으로 혈당검사와 광용적맥파 검사를 실시하여 상관관계를 분석한 결과 혈당수치에 따라 자율신경계 부교감신경이 느려지는 상관관계를 보였다. 이상의 결과에서 정량적 감각 검사가 주관적 평가에 의한 검사이기는 하나 검사의 민감도를 신뢰할 수 있다고 보이며 따라서 말초 신경의 평가도구로서 정량적 감각검사가 당뇨병성 신경병증 등의 진단의 민감도를 높이는데 폭넓게 이용될 수 있을 것으로 보이며, 광용적맥파 검사가 심박변화율에 의한 자율신경계를 평가하는 후속연구에 기초자료연구로 이용될 수 있을 것으로 사료된다.

Keywords

References

  1. Yarnitsky D, "Quantitative sensory testing", Muscle Nerv, Vol. 20, No. 2, pp.198-204, 1997. https://doi.org/10.1002/(SICI)1097-4598(199702)20:2<198::AID-MUS10>3.0.CO;2-#
  2. Gruener G, Dyck PJ, "Quantitative sensory testing: methodology, applications, and future directions", Clin Neurophysiol, Vol.11, No. 6, pp.568-583, 1994. https://doi.org/10.1097/00004691-199411000-00004
  3. Su-Hyun Kim, Sung-Min Kim, Suk-Won Ahn, Yoon-Ho Hong, Kyung Seok Park, Jung-Joon Sung, Kwang-Woo Lee, "Quantitative Sensory Test: Normal Range in Korean Adults and Application to Diabetic Polyneuropathy", J Korean Society for Clinical Neurophysiology, Vol. 12, No. 1, pp.21-26, 2010.
  4. Ik-Yong Kim, "Management of peripheral neuropathy for cancer patients", Korean Journal of Clinical Oncology Summer, Vol. 7, No. 1. pp.11-22, 2011. https://doi.org/10.14216/kjco.11002
  5. Dr. R. Kahn, "Report and recommendations of the San Antonio Conference of Diabetic Neuropathy", Annals of Neurology, Vol. 24, No. 1, pp.99-104, 1988. https://doi.org/10.1002/ana.410240120
  6. Peter James Dyck, MD, Wilfred Bushek, Eileen M Spring, Jeannine L Karnes, MS, William J Litchy, MD, Peter C O'Brien, PhD and F John Service, MD, " Vibratory and Cooling Detection Thresholds Compared With Other Tests in Diagnosing and Staging Diabetic Neuropathy", Diabetes Care. Vol. 10, No. 4, pp.432-440, 1987. https://doi.org/10.2337/diacare.10.4.432
  7. S.M. Lee, B.J. Kim, "Diagnostic Usefulness of Quantitative Sensory Test in Diabetic Polyneuropathy: Comparison with Nerve Conduction Study", J Korean Neurol Assoc, Vol. 17, No. 1, pp.106-111, 1999.
  8. Park JM, Kang SJ, Kim KW, Kim JW, Kim SH, "Evaluation of Peripheral Polyneuropathy in Patients with Diabetes Mellitus Using Quantitative Sensory Test.", J Korean Acad Rehabil Med, Vol. 25, No. 1, pp.102-109, 2001.
  9. H.J. Kim, "Electrodiagnostic and Quantitative Sensory Tests in Diabetic Neruopathy", Korean Diabetes Association, Vol. 1, No. 2, pp.138-142, 2000.
  10. I.C. Jeung, "study of the estimation for cardiovascular function and blood pressure using the photoplethysmographic signal", Yonsei University Collage of Health Science, 2004.
  11. Je-Min Song, Gye-Hwan Jin, Seo, Sung-Bo Seo, Jeong-Seok Park, Sang-Bock Lee, Keun-Ho Ryu, "Design and Implementation of a Prediction System for Cardiovascular Diseases using PPG" Journal of the Korean Society of Radiology, Vol. 5, No. 1, pp.19-25, 2011. https://doi.org/10.7742/jksr.2011.5.1.019
  12. YS Noh, SJ Park, SB Park, HR Yoon, "Design of Real-Time Autonomic Nervous System Evaluation System Using Heart Instantaneous Frequency", Journal of Electrical Engineering & Technology, Vol. 3, No. 4, pp.576-583, 2008. https://doi.org/10.5370/JEET.2008.3.4.576
  13. MH Lee, GS Jeung, JH Lee, "The Design of Autonomic Function Analysis System By Using Heart Rate Variability Signal", Institute of Control, Robotics, and Systems, Proceedings Vol. 12, No. 1, pp.1639-1642, 1997.
  14. IC Jeung, TM Shin, HR Yoon, " Estimation of non-invasive blood pressure using peripheral plethysmograph", Journal of Electrical Engineering & Technology, Vol. 54, No. 8, pp.504-509, 2005.