Abstract

Concrete is a attractive construction material, however durability problem occur due to steel corrosion, which leads propagation to structural safety problem. The recently developed FRP (Fiber Reinforced Plastic) Hybrid Bar has an engineering merit of both structural steel and FRP. Accelerated corrosion test for RC (Reinforced Concrete) samples with normal steel and FRP Hybriud Bar are performed and their flexural capacity is evaluated. Furthermore UV(Ultrasonic Velocity) measurement is attempted for analysis of variation of UV due to corrosion condition. After corrosion test, there is no significant reduction in RC beam with FRP hybrid bar but 11.5% of reduction in the case of normal steel is evaluated with 3.3% of UV reduction. For commercial production of FRP hybrid bar, bond strength evaluation through long-term submerged corrosion is required.

콘크리트는 내구적인 건설재료이지만 철근부식에 따라 내구성 문제가 발생하고 이는 구조적인 안전성 문제로 진전된다. 최근 들어 개발된 FRP hybrid bar는 기존의 FRP와 강재의 장점을 가진 것으로 본 연구에서는 이에 대한 촉진부식실험을 수행하여 휨내력저하를 평가하였다. 또한 촉진부식실험 전후에 초음파속도를 측정하여 부식에 따른 속도변화를 분석하였다. FRP hybrid bar를 매립한 RC 시편에서는 휨 내력저하가 발생하지 않았지만, 일반강재를 매립한 부재에서는 평균 11.5%의 휨 내력저하가 발생했으며, 3.3%의 초음파 속도 감소가 평가되었다. FRP hybrid bar의 내부식성은 매우 우수한 것으로 평가되었으나 실용화를 위해서는 장기침지에 따른 부착성검토가 필요하다.

Keywords

References

  1. 임홍철, 마향화, 이석용, 이근우, 오진원, "철근부식 표면측정법 모델링을 통한 콘크리트 내 철근 탐사", 한국콘크리트학회, 제21권, 제2호, pp.153-158, 2009. https://doi.org/10.4334/JKCI.2009.21.2.153
  2. 오병환, 엄주용, 권지훈, "에폭시 도포철근의 내 부식성능에 관한 실험적 연구", 한국콘크리트 학회, 제4권, 제4호, pp.161-170, 1992.
  3. E. Ramirez, J. A. Gonzalez, and A. Bautista, "The Protective Efficiency of Galvanizing against Corrosion of Steel in Mortar and in Ca(OH)2 Saturated Solutions Containing Chlorides," Cement and Concrete Research, Vol.26, No.10, pp.1525-1536, 1996. https://doi.org/10.1016/0008-8846(96)00150-0
  4. 신성우, 안종문, 한범석, 서대원, "FRP 보강근을 주근으로 사용한 콘크리트보의 보강비 효과", 대한건축학회, 제22권, 제6호, pp.19-26, 2006.
  5. ACI 440.1R-06, Guide for the Design and Construction of concrete reinforce with FRP bars, ACI Committee 440, 2006.
  6. 한국건설기술연구원, FRP Hybrid Bar를 활용한 해양항만구조물 수명 향상 기술 개발, 2013.
  7. J. H. Bungey, The Testing of Concrete in Structures, Surrey University Pub, Glasgow, 1982.
  8. R. Jones, A Review of the Non-destructive Testing of Concrete, Institution of Civil Engineers and the British National Committee for Non-destructive Testing, pp.1-7, 1970.
  9. V. R. Sturrup, R. J. Vechio, and H. Caratin, "Pulse velocity as a measure of concrete compressive strength," ACI Special Publication, 1984.
  10. D. W. Seo, K. T. Park, Y. J. You, and H. Y. Kim, "Enhancement in Elastic Modulus of GFRP Bars by Material Hybridization," Engineering, Vol.5, No.11, pp.865-869, 2013. https://doi.org/10.4236/eng.2013.511105
  11. D. W. Seo, K. T. Park, Y. J. You, and H. Y. Kim, "Evaluation for Tensile Performance of Recently Developed FRP Hybrid Bars," IJETAE, Vol.4, No.6, pp.631-637, 2014.
  12. P. Grosser, "ULTRASONIC DETECTION AND MEASURING OF ISOLATED OR PITTING CORROSION," 12th APCNDT, 2006.
  13. K. R. Olsen, "ULTRASONIC DETECTION OF SIMULATED CORROSION IN 1 INCH DIAMETER STEEL TIEBACK RODS," Doctoral Dissertation, Wasjington State University, Department of Civil and Environmental Engineering, 2009.
  14. W. Yeih and R. Huang, "DETECTION OF THE CORROSION DAMAGE IN REINFORCED CONCRETE MEMBERS BY ULTRASONIC TESTING," Cement and Concrete Research, Vol.28, No.7, pp.1071-1083, 1998. https://doi.org/10.1016/S0008-8846(98)00060-X
  15. 한국콘크리트학회, 해양 콘크리트의 염해 내구성 및 설계, 기문당, 2010.
  16. 임홍철, 마향화, 이석용, 이근우, 오진원, "철근부식 표면측정법 모델링을 통한 콘크리트 내 철근 탐사", 한국콘크리트학회, 제21권, 제2호, pp.153-158, 2009. https://doi.org/10.4334/JKCI.2009.21.2.153
  17. J. P. Broomfield, Corrosion of Steel in Concrete : Understanding, Investigation and Repair, E&FN, London, 1997.
  18. S. J. Kwon, U. J. Na, S. S. Park, and S. H. Jung, "Service Life Prediction of Concrete Wharves with Early-Aged Crack : Probabilistic Approach for Chloride Diffusion," Structural Safety, Vol.31, No.1, pp.75-83, 2009. https://doi.org/10.1016/j.strusafe.2008.03.004
  19. CEB, New Approach to Durability Design, 1997.
  20. S. H. Baek, X. Wiliam, Q. Maria, and S. J. Kwon, "Nondestructive Corrosion Detection in RC Through Integrated Heat Induction and IR Thermography," Journal of Nondestructive Evaluation, Vol.31, No.2, pp.181-190, 2012. https://doi.org/10.1007/s10921-012-0133-0
  21. S. Sakurada, H. Irie, and Y. Yoshida, "Development of Reinforced Concrete Corrosion Amount Presumption Method by Ultrasonic Method," 17th World Conference on Nondestructive Testing, Shanghai, China, pp.1-6, 2008.
  22. 김윤용, 오광진, 박기태, 권성준, "공극구조 및 하중조건에 따른 콘크리트의 초음파 속도 모델링", 콘텐츠학회논문집, 제15권, 제3호, pp.415-426, 2015.
  23. BS 1881 : Part 203, Recommendations for Measurement of Velocity of Ultrasonic Pulses in Concrete, British Standards Institution, pp.56-58, 1986.