References
- Howe, R.D. and Matsuoka, Y., 1999, Robotics for Surgery, Annual Review of Biomedical Engineering, 1, pp.211-240. https://doi.org/10.1146/annurev.bioeng.1.1.211
- Davies, B., 2000, A Review of Robotics in Surgery, Proceedings of the Institution of Mechanical Engineers, Part H, 214(1), pp.129-140. https://doi.org/10.1243/0954411001535309
- Taylor, R.H. and Stoianovici, D., 2003, Medical Robotics in Computer-integrated Surgery, IEEE Transactions on Robotics and Automation, 19(5), pp.765-781. https://doi.org/10.1109/TRA.2003.817058
- Dogangil, G., Davies, B.L. and Baena, F.R.Y., 2010, A Review of Medical Robotics for Minimally Invasive Soft Tissue Surgery, Proceedings of the Institution of Mechanical Engineers, part H, 224(5), pp.653-679.
- Lanfranco, A.R., Castellanos, A.E., Desai, J.P. and Meyers, W.C., 2004, Robotic Surgery: a Current Perspective, Annals of Surgery, 239(1), pp.14-21. https://doi.org/10.1097/01.sla.0000103020.19595.7d
- Mattei, T.A., Rodriguez, A.H., Sambhara, D. and Mendel, E., 2014, Current State-of-the-art and Future Perspectives of Robotic Technology in Neurosurgery, Neurosurgical Review, 37(3), pp.357-366. https://doi.org/10.1007/s10143-014-0540-z
- Eggers, G., Muhling, J. and Marmulla, R., 2006, Image-to-patient Registration Techniques in Head Surgery, International Journal of Oral and Maxillofacial Surgery, 35, pp.1081-1095. https://doi.org/10.1016/j.ijom.2006.09.015
- Li, Q.H., Zamorano, L., Pandya, A., Perez, R., Gong, J. and Diaz, F., 2002, The Application Accuracy of the NeuroMate Robot-a Quantitative Comparison with Frameless and Framebased Surgical Localization Systems, Computer Aided Surgery, 7(2), pp.90-98. https://doi.org/10.3109/10929080209146020
- Callovini, G., Sherkat, S. and Gazzeri, R., 2014, Frameless Nonstereotactic Image-guided Surgery of Supratentorial Lesions: Introduction to a Safe and Inexpensive Technique, Journal of Neurological Surgery, Part A: Central European Neurosurgery, 75(5), pp.365-370 https://doi.org/10.1055/s-0033-1358607
- Shin, S., Lee, D., Kim, Y. and Park, S., 2012, Markerless Registration for Intracerebral Hemorrhage Surgical System using Weighted Iterative Closest Point (ICP), Proceedings of 34th Annual International Conference of the IEEE EMBS, pp.5306-5309.
- Wang, C., 1992, Extrinsic Calibration of a Vision Sensor Mounted on a Robot, IEEE Trans. Robot. Automat. 8, pp.161-175. https://doi.org/10.1109/70.134271
- Shiu, Y. and Ahmad, S., 1989, Calibration of Wrist-mounted Robotic Sensors by Solving Homogeneous Transform Equations of the Form AX=XB, IEEE Trans. Robot. Automat. 5, pp.16-27. https://doi.org/10.1109/70.88014
- Tsai, R.Y. and Lenz, R.K., 1989, A New Technique for Fully Autonomous and Efficient 3D Robotics Hand/eye Calibration, IEEE T Robotic Autom. 5(3), pp.345-358. https://doi.org/10.1109/70.34770