DOI QR코드

DOI QR Code

Load Modeling based on System Identification with Kalman Filtering of Electrical Energy Consumption of Residential Air-Conditioning

  • Patcharaprakiti, Nopporn (Department of Electrical Engineering, Rajamangala University of Technology Lanna Chiangrai) ;
  • Tripak, Kasem (Department of Electrical Engineering, Rajamangala University of Technology Lanna Lampang) ;
  • Saelao, Jeerawan (Department of Mathematics, Faculty of Science, Maejo University)
  • 투고 : 2015.01.23
  • 심사 : 2015.03.22
  • 발행 : 2015.05.30

초록

This paper is proposed mathematical load modelling based on system identification approach of energy consumption of residential air conditioning. Due to air conditioning is one of the significant equipment which consumes high energy and cause the peak load of power system especially in the summer time. The demand response is one of the solutions to decrease the load consumption and cutting peak load to avoid the reservation of power supply from power plant. In order to operate this solution, mathematical modelling of air conditioning which explains the behaviour is essential tool. The four type of linear model is selected for explanation the behaviour of this system. In order to obtain model, the experimental setup are performed by collecting input and output data every minute of 9,385 BTU/h air-conditioning split type with $25^{\circ}C$ thermostat setting of one sample house. The input data are composed of solar radiation ($W/m^2$) and ambient temperature ($^{\circ}C$). The output data are power and energy consumption of air conditioning. Both data are divided into two groups follow as training data and validation data for getting the exact model. The model is also verified with the other similar type of air condition by feed solar radiation and ambient temperature input data and compare the output energy consumption data. The best model in term of accuracy and model order is output error model with 70.78% accuracy and $17^{th}$ order. The model order reduction technique is used to reduce order of model to seven order for less complexity, then Kalman filtering technique is applied for remove white Gaussian noise for improve accuracy of model to be 72.66%. The obtained model can be also used for electrical load forecasting and designs the optimal size of renewable energy such photovoltaic system for supply the air conditioning.

키워드

참고문헌

  1. Boshell F. KEMA, Bogota Veloza O.P., "Review of developed demand side management programs including different concepts and their results," Transmission and Distribution Conference and Exposition: Latin America, 2008 IEEE/PES, pp. 1-7, August 13-15, 2008.
  2. L. G. DIAS , M. E. EL-HAWARY, "Electric power system static load model parameter estimation using Newton's method Electric Machines & Power Systems," Vol. 14, Issue 5, pp. 317-328, 1988. https://doi.org/10.1080/07313568808909294
  3. Jonathan Berardino, Chika Nwankpa "Dynamic Load Modeling of an HVAC Chiller for Demand Response Applications," Smart grid conference, 2012, Washington DC.
  4. Danlel Karlsson, David J. Hill "Modeling and Identification of Nonlinear dynamic loads in power systems," IEEE Transactions on Power System, Vol. 9, No. 1, pp. 157, February 1994. https://doi.org/10.1109/59.317546
  5. Saverio Bolognani, Guido Cavraro, Federico Cerruti, and Alessandro Costabeber, "A linear dynamic model for microgrid voltages in presence of distributed generation,"
  6. P. Pourbeik and B. Agrawal, "A hybrid model for representing air-conditioner compressor motor behavior in power system studies," in Proc. IEEE PES General Meeting, July 2008.
  7. Henrik Sandberg, Kin Cheong Sou, "Introduction to model order reduction," Royal Institute of Technology
  8. Chen, Chung-Wen , Lee, Gordon; Je-Nan Juang, "An Improved Autoregressive Spectral Estimation Method Using the Kalman Filter System Identification Technique," American Control Conference, 1993, pp. 930-934, June 2-4, 1993.
  9. N. Patcharaprakiti, K. Kirtikara, D. Chenvidhya, V. Monyakul, B.Muenpinij, "Modeling of Single Phase Inverter of Photovoltaic System using System Identification," 2010 International Conference on Systems Engineering and Modeling, ICSEM 2010, April 23-25, 2010, Bangkok, Thailand.
  10. N. Patcharaprakiti, J.Thongpron, K. Kirtikara and J.Saelao, "Model order reduction of grid connected inverter model based on system identification," The fifth IASTED Asian conference on Power and Energy, April 2-4, 2012, Phuket, Thailand.
  11. Glover, K., "All Optimal Hankel Norm Approximation of Linear Multivariable Systems, and Their L - error Bounds," Int. J. Control, Vol. 39, No. 6, pp. 1145-1193, 1984.
  12. Safonov, M.G., R.Y. Chiang, and D.J.N. Limebeer, "Optimal Hankel Model Reduction for Nominal Systems," IEEE Trans. on Automat. Contr., Vol. 35, No. 4, pp. 496-502, April 1990. https://doi.org/10.1109/9.52314
  13. Varga, A., "Balancing-Free Square-Root Algorithm for Computing Singular Perturbation Approximations," Proc. of 30th IEEE CDC, Brighton, pp. 1062-1065, 1991, UK.
  14. Greg, W., and Gary, B., "An Introduction to the Kalman Filter," UNC-Chapel Hill, pp.1-15, 2006.