DOI QR코드

DOI QR Code

Cyclic testing of weak-axis column-tree connections with formation of plastic hinge at beam splice

  • Oh, Keunyeong (Department of Architectural Engineering, Chungnam National University) ;
  • Chen, Liuyi (Department of Architectural Engineering, Chungnam National University) ;
  • Hong, Sungbin (Department of Architectural Engineering, Chungnam National University) ;
  • Yang, Yang (Department of Architectural Engineering, Chungnam National University) ;
  • Lee, Kangmin (Department of Architectural Engineering, Chungnam National University)
  • 투고 : 2014.05.08
  • 심사 : 2014.12.27
  • 발행 : 2015.05.25

초록

The purpose of this study was to evaluate the seismic performance of weak-axis column-tree type connections used in steel moment frames. These connections are composed of a shop-welded and fieldbolted steel structure and can improve welding quality. On this basis, column-tree type connections are widely used in steel moment resisting frames in Korea and Japan. In this study, splices designed with a semirigid concept regarding the seismic performance of column-tree connections were experimentally evaluated. The structures can absorb energy in an inelastic state rather than the elastic state of the structures by the capacity design method. For this reason, the plastic hinge might be located at the splice connection at the weak-axis column-tree connection by reducing the splice plate thickness. The main variable was the distance from the edge of the column flange to the beam splice. CTY series specimens having column-tree connections with splice length of 600 mm and 900 mm were designed, respectively. For comparison with two specimens with the main variable, a base specimen with a weak-axis column-tree connection was fabricated and tested. The test results of three full-scale test specimens showed that the CTY series specimens successfully developed ductile behavior without brittle fracture until 5% story drift ratio. Although the base specimen reached a 5% story drift ratio, brittle fracture was detected at the backing bar near the beam-to-column connection. Comparing the energy dissipation capacity for each specimen, the CTY series specimens dissipated more energy than the base specimen.

키워드

과제정보

연구 과제 주관 기관 : National Research Foundation of Korea (NRF)

참고문헌

  1. AISC (2010), Seismic provision for structural steel building, American Institute of Steel Structure, Chicago, IL, USA.
  2. Astaneh-Asl, A. (1997), "Seismic design of steel column-tree moment-resisting frames", Structural Steel Educational Council.
  3. FEMA (2000), Recommended Seismic Design Criteria for New Steel Moment-Frame Buildings: FEMA-350, SAC Joint Venture, Richmond, Caliph, USA.
  4. Han, S.W., Kwon, G.U. and Moon, K.H. (2007), "Cyclic behavior of post-Northridge WUF-B connections", J. Constr. Steel Res., 63(3), 365-374. https://doi.org/10.1016/j.jcsr.2006.05.003
  5. Hisashi, Okada, et al. (2001), Recommendation for Design of Connections in Steel Structures, Architectural Institute of Japan, Japan.
  6. Kim, S.S., Lee, D.H. and et al. (2004), "Development of beam-to-column connection details with horizontal stiffness in weak axis of H-shape column", J. Korean Soc. Steel Constr., 16(5), 641-652.
  7. KS B 0801 (2007), Test Pieces for Tensile Test for Metallic Materials, Korean Industrial Standards, Korea.
  8. Lee, C.H. and Park, J.W. (1998), "Cyclic seismic testing of full-scale column-tree type steel moment connections", J. Korean Soc. Steel Constr., 10(4), 629-639.
  9. Lee, K., Li, R., Chen, L., Oh, K. and Kim, K.S. (2014), "Cyclic testing of steel column-tree moment connections with various beam splice lengths", Steel Compos. Struct., 16(2), 221-231. https://doi.org/10.12989/scs.2014.16.2.221
  10. Mahin, S.T. (1998), "Lessons from damage to steel buildings during the Northridge earthquake", Eng. Struct., 20(4-6), 261-270. https://doi.org/10.1016/S0141-0296(97)00032-1
  11. McMullin, K.M. and Astaneh-Asl, A. (2003), "Steel semirigid column-tree moment resisting frame seismic behavior", J. Struct. Eng., 129(9), 1243-1249. https://doi.org/10.1061/(ASCE)0733-9445(2003)129:9(1243)
  12. Miller, D.K. (1998), "Lessons learned from the Northridge earthquake", Eng. Struct., 20(4-6), 249-260. https://doi.org/10.1016/S0141-0296(97)00031-X
  13. Nader, M.N. and Astaneh-Asl, A. (1996), "Shaking table tests of rigid, semirigid, and flexible steel frames", J. Struct. Eng., 122(6), 589-596. https://doi.org/10.1061/(ASCE)0733-9445(1996)122:6(589)
  14. Tsai, K.C., Wu, S. and Popov, E.P. (1995), "Experimental performance of seismic steel beam-column moment joints", J. Struct. Eng., 121(6), 925-931. https://doi.org/10.1061/(ASCE)0733-9445(1995)121:6(925)

피인용 문헌

  1. Seismic performance evaluation of Korean column-tree steel moment connections vol.16, pp.4, 2016, https://doi.org/10.1007/s13296-016-0089-5
  2. Seismic behaviour of post-tensioned precast concrete beam-column connections vol.73, pp.9, 2015, https://doi.org/10.1680/jmacr.19.00083