참고문헌
- Kwak JH, Jeong JB, "A Study on the Guardan's Perception of Attending Patient in Pediatric Radiology", J. Korean Soc. Radiology, Vol. 8, No. 4, pp.189-201, 2014. https://doi.org/10.7742/jksr.2014.8.4.189
- Lee IJ, Kim HY, Kim NC, Lee YC, Park YK, "Evaluation of image According to Exposure Conditions using Contrast-Detail Phantom for Chest Digital Radiography", J. Radiological Science and Technology, Vol. 32, No. 1, pp.25-32, 2009.
- Jo KH, Kang YH, Kim BS, "A Study on the Exposure Parameter and the Patient Dose for Digital Radiography System in Dae Goo", J. Korean Soc. Radiol. Science, Vol. 31, No. 2, pp.177-182, 2008.
- Kim YH, "Method for Measurement of Entrance Surface Dose and Role of Radiation technologist", J. Radiological Science and Technology, Vol. 28, No. 3, pp.173-191, 2005.
- Ullman G, Svendborg M, Dance DR, Hunt R, Alm Carlsson G, "The influence of patient thickness and imaging system on patient dose and physical image quality in chest image", Radiat. Prot. Dosimetry, Vol.114, No. 1-3, pp.294-297, 2005. https://doi.org/10.1093/rpd/nch542
- Jung JS, Choi BU, Kim SH, Kim YM, Shim JN, Ahn HS, Jin DE, Lim JS, Kang SH, "Effect of Automatic Exposure Control Marker with Chest Radiography in Radon Reduction", J. Radiological Science and Technology, Vol. 32, No. 1, pp.25-32, 2009.
- Choi NG, Seong HJ, Jeon JS, Kim YH, Seong DO, "A Comparative Study of Image Quality and Radiation Dose according to Variable Added Filter and Radiation Exposure in Diagnostic X-ray Radiography", J. Radiation protection, Vol. 37, No. 1, pp.25-34, 2012. https://doi.org/10.14407/jrp.2012.37.1.025
- Huh J, Kim CK, LEE IJ, Shin WS, Park JC, Kang HS, Ahn BS, "A study on the effect of rare earth screen Filter", J. Korean Soc. Radiological technology, Vol. 11, No. 1, pp.17-23, 1988.
- Shin SG, "Decreased of Patient dose by Built-in Filter in Pelvis A-P Projection", J. Korean Contents Association, Vol. 12, No. 8, pp.233-239, 2012.
- Seok DW, "Evaluation of Imaging Performance of the a-Se based Flat-panel X-ray Detector System using MTF, NPS and DQE measurements", The graduate school of Inje University, 2004.
- Lee JS, Ko SJ, Kang SS, Kim JH, Kim DH, Kim CS, "Quantitative Evaluation of Image Quality using Automatic Exposure Control & Sensitivity in the Digital Chest Image", J. Korean Contents Association, Vol. 13, No. 8, pp.275-283, 2013.
- Choi KM, Shin SI, Yoon JM, Kim SC, Lee SS, Huh J, "The Reduction of Radiation Dose using Key-Filter in Chest Radiography", J. Radiological Science and Technology, Vol. 19, No. 2, pp.173-191, 1996.
- Schaefer-Prokop C, Neitzel U, Venema HW, Uffmann M, Prokop M; "Digital chest radiography: an update on modern technology, dose containment and control of image quality", European Radiology, Vol. 18, Issue 9, pp.1818-1830, 2008. https://doi.org/10.1007/s00330-008-0948-3
- Kim YS, Park HS, Park SJ, Kim HJ, "Effective Detective Quantum Efficiency (eDQE) Evaluation for the Influence of Focal Spot Size and Magnification on the Digital Radiography System", Korean journal of medical physis, Vol. 23, No. 1, pp.26-32, 2012.
- Kwon SM, Park CH, Park JK, Song UH, Jung JE, "The Effect of Source to Image-Receptor Distance(SID) on Radiation Dose for Digital Chest Radiography", J. Korean Soc. Radiology, Vol. 8, No. 4, pp.203-210, 2014. https://doi.org/10.7742/jksr.2014.8.4.203
- "ICRP, 2007 Recommendations of the International Commission on Radiological Protection Publication 103", Annals of the ICRP Vol. 137, No. 2-4, Pergamon Press, Oxford, 2007.
피인용 문헌
- A Convergence Study on Evaluation of Usefulness of Copper Additional Filter in the Digital Radiography System vol.13, pp.9, 2015, https://doi.org/10.14400/JDC.2015.13.9.351
- The Study of Forward Scattering Dose according to the Thickness of Filter in General Radiography vol.9, pp.7, 2015, https://doi.org/10.7742/jksr.2015.9.7.445
- The Study of Affecting Image Quality according to forward Scattering Dose used Additional Filter in Diagnostic Imaging System vol.10, pp.8, 2016, https://doi.org/10.7742/jksr.2016.10.8.597
- 인터벤션 시 방사선조사 조건에 따른 선량감소 : 면적선량과 영상화질 변화를 중심으로 vol.40, pp.3, 2015, https://doi.org/10.17946/jrst.2017.40.3.06
- 자동노출제어장치의 채광창 차폐정도와 농도, 감도의 변화가 관전류량과 영상품질에 미치는 영향 vol.14, pp.5, 2015, https://doi.org/10.7742/jksr.2020.14.5.635
- 미세 대조도 영상을 기반한 디지털 방사선 영상 시스템의 자동노출제어 조절인자 간의 상관관계 분석 vol.44, pp.1, 2015, https://doi.org/10.17946/jrst.2021.44.1.1
- 부비동 디지털 엑스선검사에서 자동노출제어 조절인자의 최적화를 통한 조사선량 감소 효과 vol.44, pp.3, 2015, https://doi.org/10.17946/jrst.2021.44.3.173