Currently, the United States, the United Kingdom, Australia etc. are actively utilizing energy simulation for efficiency evaluation of building energy. However, domestic energy efficiency assessment system doesn't use energy simulation system properly at present: parameters based architecture plans and Ashrae Standard are inputted for the evaluation, because the input parameters for the simulation haven't been established yet. This fact causes poor reliability during energy simulation, as the values of the two standards are different from each other. Therefore, the aim of the study is to set domestic standard parameter for BIM-based energy performance evaluation, focusing on possession area per person of occupants at government office in Korea. We found that the difference among the result values occurred approximately 3% in the energy simulation. As a result of the analysis, possession area per person of occupants in Government office is $31.87m^2$. Other input parameters may be set based on this. This will increase the reliability of energy simulation through a domestic standard parameter.

키워드

참고문헌

  1. KMA, http://www.kma.go.kr/index.jsp
  2. Suh, W.-J. and Park, C.-S., 2012, Issues and Limitations on the Use of a Whole Building Simulation Tool for Energy Diagnosis of a Reallife Building, Journal of the Architectural Institute of Korea, 28(1), pp.273-283.
  3. Dbpia, www.dbpia.co.kr
  4. Kim, H.-G., Jang, H.-I. and Park, C.-Y., Yoon S.-H., Choi, C.-H. and Hong, J.-P., 2013, Comparison of Analysis Results between Quasisteady- state Method Based on ISO 13790 and Dynamic Method Using Weather Data, Journal of KIAEBS, 7(4), pp.274-280.
  5. Jo, J.-S., Choo, S.-Y. and Choi, M.-H., 2011, A Study on Applying Green BIM to Sustainable Architecture at Early Design Stage - Focused on Energy Performance Analysis - Journal of the Architectural Institute of Korea, 27(4), pp.13-24
  6. Choo, S.-Y., Lee, K.-H. and Park, S.-K., 2012, A Study on LOD(Level of Development) for Development of Green BIM Guidelines - Focused on Energy Performance Estimation, Journal of the Architectural Institute of Korea, 28(6), pp.37-47
  7. Ministry of Land, Transport and Maritime Affairs, 2012, Window Design Guideline for Conservation of Energy in Building.
  8. Lee, C.-G., 2013, Economical and Energy Analysis of Standard Rural House Model and KNU Plant Factory, Kongju University.
  9. Lee, J.-G., 2013, A Study on Improvement Plan for Accuracy of Building Energy Simulation Using BIM : Focused on Remodeling Design Stage, Hanyang University.
  10. Kim, I.-H., Kim, E.-J. and Choi, J.-S., 2011, Development of the IFC based IDF Converter for Energy Performance Assessment in the Early Design Phase, Transactions of the Society of CAD/CAM Engineers, 16(2), pp.146-155.
  11. Song, S.-W., Yang, H.-M. Lee, J.-H. and Mun, Y.-J., 2011, A Study on Improving the Building Energy performance Rating of a Public Office Building Using a Dynamic Energy Simulation Program, Journal of the Architectural Institute of Korea, 27(11), pp.381-391.
  12. Park, G.-H., 2012, Construction of National Energy Conservation Policy Evaluation System, Korea Energy Economics Institute.
  13. KEMCO, http://www.kemco.or.kr/
  14. MOLIT, http://www.molit.go.kr
  15. Ahn, K.-U., Kim, Y.-J. and Park, C.-S., 2012, Issues on Dynamic Building Energy Performance Assessment in Design Process, Journal of the Architectural Institute of Korea, 28(12), pp.361-369.
  16. Lee, K.-H., Kim, I.-H. and Choo, S.-Y., 2011, A Study on Improvement of Energy Performance Index in Green Building Certification System using BIM, Journal of the Architectural Institute of Korea, 27(9), pp.13-21.
  17. Lee, K.-H., Ryu, J.-R., Lee, J.-W. and Choo, S.-Y., 2013, A Study on Office Building Usage Schedule Setting for Green BIM-Based Architectural Planning Support, Proceedings of the Architectural Institute of Korea, 33(2), pp.67-68.
  18. Kepco, http://cyber.kepco.co.kr/kepco/main.do
  19. PPS, www.pps.go.kr