DOI QR코드

DOI QR Code

오피스 건물에서 인접건물이 자연채광 성능에 미치는 영향

A Study of the Daylighting Performance in Obstructed Office Building in Urban Area

  • 박웅규 (삼성물산 빌딩사업본부) ;
  • 기현주 (성균관대학교대학원 글로벌건설 ENG학과) ;
  • 정찬울 (성균관대학교대학원 글로벌건설 ENG학과) ;
  • 송두삼 (성균관대학교 건축공학과)
  • Park, Woong-Kyu (Dept. of Building, Samsung C&T) ;
  • Ki, Hyun-Joo (Dept. of Global Construction Eng., Graduate School, Sungkyunkwan University) ;
  • Jeong, Chan-Woul (Dept. of Global Construction Eng., Graduate School, Sungkyunkwan University) ;
  • Song, Doo-Sam (Dept. of Architectural Eng., Sungkyunkwan University)
  • 투고 : 2014.09.17
  • 심사 : 2014.10.22
  • 발행 : 2014.10.30

초록

The performance of the daylighting in buildings depends on building site and shape. As an energy saving design strategy, daylighting is a key issue in green building design. In this paper, the influence of the adjacent or obstructed building on daylighting performance of the office building in urban area was analyzed. A typical office building about 20 storeys with obstructed buildings has been modeled and simulated using Radiance. The parametric simulations have been performed to analyze the influence of the daylighting performance (illuminance, luminance) of the analyzed office. The results show that the possibility of the glare was decreased when the obstructed building is located in south, also the illuminance level was significantly decreased. When the obstructed building is located in north, the changes of the illuminance level and luminance possibility were somewhat small compared to the unobstructed condition. The daylighting performance of the analyzed building was most affected by the obstructed building in winter season.

키워드

참고문헌

  1. BUILDING ACT-Article 58 (VacantLotwithin Building Site), Korea Ministry of Government Legislation, 2013
  2. LiD. H. W., Wong S. L., Tsang C. L., Gary H. W. Cheung, A study of the daylighting performance and energy use in heavily obstructed residential buildings via computer simulation techniques, Energy and Buildings 38, pp. 1343-1348, 2006 https://doi.org/10.1016/j.enbuild.2006.04.001
  3. Issac Guedi Capeluto, The influence of the urban environment on the availability of daylighting in office buildings in Israel, Building and Environment 38(5), pp. 745-752, 2013
  4. CIBSE, Chartered institution of building services engineers, applications manual:window design. London: CIBSE, 1987
  5. LiD. H. W., Wong S. L., Daylighting and energy implications due to shading effects from nearby buildings, Applied Energy 84, pp. 1199- 1209, 2007 https://doi.org/10.1016/j.apenergy.2007.04.005
  6. http://radsite.lbl.gov/radiance/framed.html
  7. Park W. K., Park T. J., Kang G. M., Lee S. Y., Song D. S., Validation of the prediction equation for interior daylight illuminance using radiance simulation, SAREK, pp. 694-698, 2013
  8. Masanori Shukuya, Environmental Architecture in light and heat by numerical study, Maruzen Co. Ltd., pp. 17-84, 1993
  9. Mark S. Rea, LIGHTING HANDBOOK, IESNA, pp. 8-12, 2000