Abstract
In the fields of reliability application, the most commonly used test methods for reliability demonstration are zero-failure acceptance tests since they require fewer test samples and less test time compared to other test methods that guarantee the same reliability with a given confidence level. For products with lognormal lifetime distribution, the value of scale parameter is usually assumed to be known in designing reliability demonstration tests. It is important to select correct values of scale parameters to guarantee the specified reliability with given confidence level exactly. The effect of using wrong values of scale parameters in designing reliability demonstration test for products with lognormal lifetime distribution is examined and selecting proper values of scale parameters for conservative reliability demonstration is discussed.