Abstract

The objective of this test series was to determine shear load per unit length which causes a unit slip in the fastener joint. The shear load is one of major factors which reflect partial composite action for cold-formed steel wall stud panels. Test method used were based on the methods presented in the 1962 AISI Specification. According to the comparison with experimental strength, it is seen that the shear loads used in nominal axial strength predictions made acceptable results.

본 연구의 대상은 석고보드와 냉간성형강 스터드로 구성된 벽체용 합성패널이다. 양면의 석고보드 사이에 위치한 스터드는 나사로 연결되어 있고, 이와 같은 연결부의 부분합성거동을 정량화하여 나사접합부의 단위미끄럼을 유발하는 단위길이 당 전단하중($S_{slip}$)을 산정하는 것이 목적이었다. 실험방법은 1962 AISI규준을 기초로 하여 실시하였다. 본 연구에서 산정한 $S_{slip}$값을 이용한 이론적 추정치와 기 발표된 공칭축강도의 실험값과의 비교에서 만족할 만한 결과를 도출하였다. 그러므로 본 연구의 결과는 연구범위와 유사한 냉간성형강 부재의 해석과 설계에 있어 구조 기술자에게 가치가 있는 정보를 제공할 것이다.

Keywords

References

  1. American Iron and Steel Institute (1962). Specification for the design of cold-formed steel structural members, Washington, D.C.
  2. Green, G. G., Winter, G. and Cuykendall, T. R. (1947). Light gage steel columns in wall-braced panels, Bulletin No35, Part2, Engineering Experiment Station, Cornell University, Ithaca, N.Y.
  3. Kuenzi, E. W. and Wilkinson, T. L. (1971). "Composite beams-effect of adhesive or fastener rigidity." Research Paper FPL 152, Forest Products Laboratory, Forest Service, U.S. Dept. of Agriculture, Madison, Wis.
  4. Lee, Y. K. (2005). "Programming of beam/column analytical process for composite wall panels." Journal of Korean Society of Steel Construction, KSSC, Vol. 17, No. 1, pp. 45-52 (in Korean).
  5. Miller, T. H. (1990). Behavior of cold-formed steel wall stud assemblies subject to eccentric axial load, Ph. D. Dissertation, Cornell University, Ithaca, N.Y.
  6. Newmark, N. M., Siess, C. P. and Viest, I. M. (1951). "Tests and analysis of composite beams with incomplete interaction." Society for Experimental Stress Analysis, Vol. 9, No. 1, pp. 75-92.