참고문헌
- Ariga, T., Kanno, Y. and Takewaki, I. (2006), "Resonant behaviour of base-isolated high-rise buildings under long-period ground motions", Struct. Des. Tall Spec. Build., 15(3), 325-338. https://doi.org/10.1002/tal.298
- Ates, S. (2012), "Investigation of effectiveness of double concave friction pendulum bearings", Comput. Concr., 9(3), 195-213. https://doi.org/10.12989/cac.2012.9.3.195
- Ates, S. and Yurdakul, M. (2011), "Site-response effects on RC buildings isolated by triple concave friction pendulum bearings", Comput. Concr., 8(6), 693-715. https://doi.org/10.12989/cac.2011.8.6.693
- Bangladesh National Building Code (1993), BNBC. Bangladesh: Housing and Building Research Institute, Bangladesh Standard and Testing Institute.
- Chen, Y.Q. and Constantinou, M.C. (1990), "Use of Teflon sliders in a modification of the concept of soft first storey", Eng. Struct., 12(4), 243-253. https://doi.org/10.1016/0141-0296(90)90023-L
- Chen, Y.Q. and Constantinou, M.C. (1992), "Use of Teflon sliders in a modification of the concept of soft first storey", Construct. Build. Mater., 6(2), 97-105. https://doi.org/10.1016/0950-0618(92)90058-7
- Dall'Asta, A. and Ragni, L. (2006), "Experimental tests and analytical model of high damping rubber dissipating devices", Eng. Struct., 28(13), 1874-1884. https://doi.org/10.1016/j.engstruct.2006.03.025
- Dall'Asta, A. and Ragni, L. (2008), Nonlinear behavior of dynamic systems with high damping rubber devices, Eng. Struct., 30(12), 3610-3618. https://doi.org/10.1016/j.engstruct.2008.06.003
- Habibullah, A. (2005), SAP 2000, Static and Dynamic Finite Element Analysis of Structures. Computers and Structures Inc. Berkeley, California.
- Hussain, R.R., Saiful, I.A.B.M. and Ahmad, S.I. (2010), "Base Isolators as Earthquake Protection Devices in Buildings (First ed.): VDM Publishing House Ltd. Benoit Novel", Simultaneously published in USA & U.K.
- Islam, A.B.M.S., Ahmad, S.I., Jameel, M. and Zamin, M.J. (2012a), "Seismic base isolation for buildings in regions of low to moderate seismicity: practical alternative design", Pract. Period. Struct. Des. Construct., 17(1), 13-20. https://doi.org/10.1061/(ASCE)SC.1943-5576.0000093
- Islam, A.B.M.S., Hussain, R.R., Jameel, M. and Jumaat, M.Z. (2012b), "Non-linear time domain analysis of base isolated multi-storey building under site specific bi-directional seismic loading", Autom. Construct., 22, 554-566. https://doi.org/10.1016/j.autcon.2011.11.017
- Islam, A.B.M.S., Hussain, R.R., Jumaat, M.Z. and Rahman, M.A. (2013a), "Nonlinear dynamically automated excursions for rubber-steel bearing isolation in multi-storey construction", Autom. Construct., 30(0), 265-275. https://doi.org/10.1016/j.autcon.2012.11.010
- Islam, A.B.M.S., Jameel, M., Ahmad, S.I. and Jumaat, M.Z. (2011a), "Study on corollary of seismic base isolation system on buildings with soft story", Int. J. Phys.. Sci., 6(11), 2654-2661.
- Islam, A.B.M.S., Jameel, M., Ahmad, S.I., Salman, F.A. and Jumaat, M.Z. (2011b), "Engendering earthquake response spectra for Dhaka region usable in dynamic analysis of structures", Sci. Search Essays, 6(16), 3519-3530. https://doi.org/10.5897/SRE11.218
- Islam, A.B.M.S., Jameel, M., Jumaat, M.Z. and Rahman, M.M. (2013b), "Optimization in structural altitude for seismic base isolation at medium risk earthquake disaster region", Disaster Adva., 6(1), 23-34.
- Islam, A.B.M.S., Jameel, M., Rahman, M.A. and Jumaat, M.Z. (2011c), "Earthquake Time history for Dhaka, Bangladesh as competent seismic record", Int. J. Phys. Sci., 6(16), 3921-3926.
- Islam, A.B.M.S., Jameel, M., Uddin, M.A. and Ahmad, S.I. (2011d), "Simplified design guidelines for seismic base isolation in multi-storey buildings for Bangladesh National Building Code (BNBC), Int. J. the Phys. Sci., 6(23), 5467 - 5486.
- Islam, A.B.M.S., Jameel, M., Uddin, M.A. and Jumaat, M.Z. (2012c), "Competent Building Elevation for Incorporating Base Isolation in Aseismic Structure", Procedia Eng., 50(0), 882-892. https://doi.org/10.1016/S1877-7058(14)00002-2
- Jangid, R.S. (2007), "Optimum lead-rubber isolation bearings for near-fault motions", Eng. Struct., 29(10), 2503-2513. https://doi.org/10.1016/j.engstruct.2006.12.010
- Khoshnoudian, F. and Azad, A.I. (2011), "Effect of two horizontal components of earthquake on nonlinear response of torsionally coupled base isolated structures", Struct. Des. Tall Spec.Build., 20(8), 986-1018. https://doi.org/10.1002/tal.571
- Kilar, V. and Koren, D. (2009), "Seismic behaviour of asymmetric base isolated structures with various distributions of isolators", Eng. Struct., 31(4), 910-921. https://doi.org/10.1016/j.engstruct.2008.12.006
- Kirac, N., Dogan, M. and Ozbasaran, H. (2011), "Failure of weak-storey during earthquakes", Eng. Fail. Anal., 18(2), 572-581. https://doi.org/10.1016/j.engfailanal.2010.09.021
- Mo, Y.L. and Chang, Y.F. (1995), "Application of base isolation concept to soft first story buildings", Comput. Struct., 55(5), 883-896. https://doi.org/10.1016/0045-7949(94)00433-4
- Sharma, A. and Jangid, R.S. (2011), "Influence of high initial isolator stiffness on the seismic response of a base-isolated benchmark building", Int. J. Struct. Stab. Dyn., 11(6), 1201-1228 https://doi.org/10.1142/S0219455411004543
- Sharma, A. and Jangid, R.S. (2012), "Performance of variable curvature sliding isolators in base-isolated benchmark building", Struct. Des. Tall Spec.Build., 21(5), 354-373. https://doi.org/10.1002/tal.600
- Soni, D.P., Mistry, B.B., Jangid, R.S. and Panchal, V.R. (2011), "Seismic response of the double variable frequency pendulum isolator", Struct. Control Health Monit., 18(4), 450-470. https://doi.org/10.1002/stc.384
- Uniform Building Code (UBC) (1997), "Earthquake regulations for seismic isolated structures", Paper presented at the International conference of building officials, Whitter (CA,USA).
- Wibowo, A., Wilson, J.L., Lam, N.T.K. and Gad, E.F. (2010), "Collapse modelling analysis of a precast soft storey building in Australia", Eng. Struct., 32(7), 1925-1936. https://doi.org/10.1016/j.engstruct.2010.03.003
- Wilkinson, S. and Hiley, R. (2006), "A non-linear response history model for the seismic analysis of highrise framed buildings", Comput. Struct., 84(5-6), 318-329. https://doi.org/10.1016/j.compstruc.2005.09.021
- Yoshimura, M. (1997), "Nonlinear analysis of a reinforced concrete building with a soft first story collapsed by the 1995 Hyogoken-Nanbu earthquake", Cement Concrete Compos., 19(3), 213-221. https://doi.org/10.1016/S0958-9465(97)00016-4
피인용 문헌
- Retrofitting of vulnerable RC structures by base isolation technique vol.9, pp.3, 2015, https://doi.org/10.12989/eas.2015.9.3.603
- Comparing calculation methods of storey stiffness to control provision of soft storey in seismic codes vol.11, pp.1, 2016, https://doi.org/10.12989/eas.2016.11.1.001
- Incorporation preference for rubber-steel bearing isolation in retrofitting existing multi storied building vol.16, pp.4, 2015, https://doi.org/10.12989/cac.2015.16.4.503
- Potential Design of Seismic Vulnerable Buildings Incorporating Lead Rubber Bearing vol.9, pp.2, 2019, https://doi.org/10.3390/buildings9020037
- Determination of bearing type effect on elastomeric bearing selection with SREI-CAD vol.2, pp.1, 2014, https://doi.org/10.12989/acd.2017.2.1.043
- Identifying stiffness irregularity in buildings using fundamental lateral mode shape vol.12, pp.4, 2017, https://doi.org/10.12989/eas.2017.12.4.437
- Seismic response variation of multistory base-isolated buildings applying lead rubber bearings vol.21, pp.5, 2014, https://doi.org/10.12989/cac.2018.21.5.495
- Computer aided failure prediction of reinforced concrete beam vol.25, pp.1, 2020, https://doi.org/10.12989/cac.2020.25.1.067