DOI QR코드

DOI QR Code

A Rapid Method for Estimating the Levels of Urinary Thiobarbituric Acid Reactive Substances for Environmental Epidemiologic Survey

  • Kil, Han-Na (Department of Preventive Medicine and Medical Research Institute, College of Medicine, Chungbuk National University) ;
  • Eom, Sang-Yong (Department of Preventive Medicine and Medical Research Institute, College of Medicine, Chungbuk National University) ;
  • Park, Jung-Duck (Department of Preventive Medicine, Chung-Ang University, College of Medicine) ;
  • Kawamoto, Toshihiro (Department of Environmental Health, University of Occupational and Environmental Health) ;
  • Kim, Yong-Dae (Department of Preventive Medicine and Medical Research Institute, College of Medicine, Chungbuk National University) ;
  • Kim, Heon (Department of Preventive Medicine and Medical Research Institute, College of Medicine, Chungbuk National University)
  • Received : 2013.11.20
  • Accepted : 2014.02.13
  • Published : 2014.03.31

Abstract

Malondialdehyde (MDA), used as an oxidative stress marker, is commonly assayed by measuring the thiobarbituric acid reactive substances (TBARS) using HPLC, as an indicator of the MDA concentration. Since the HPLC method, though highly specific, is time-consuming and expensive, usually it is not suitable for the rapid test in large-scale environmental epidemiologic surveys. The purpose of this study is to develop a simple and rapid method for estimating TBARS levels by using a multiple regression equation that includes TBARS levels measured with a microplate reader as an independent variable. Twelve hour urine samples were obtained from 715 subjects. The concentration of TBARS was measured at three different wavelengths (fluorescence: ${\lambda}-_{ex}$ 530 nm and ${\lambda}-_{em}$ 550 nm; ${\lambda}-_{ex}$ 515 nm and ${\lambda}-_{em}$ 553 nm; and absorbance: 532 nm) using microplate reader as well as HPLC. 500 samples were used to develop a regression equation, and the remaining 215 samples were used to evaluate the validity of the regression analysis. The induced multiple regression equation is as follows: TBARS level (${\mu}M$) = -0.282 + 1.830 ${\times}$ (TBARS level measured with a microplate reader at the fluorescence wavelengths ${\lambda}-_{ex}$ 530 nm and ${\lambda}-_{em}$ 550 nm, ${\mu}M$) -0.685 ${\times}$ (TBARS level measured with a microplate reader at the fluorescence wavelengths ${\lambda}-_{ex}$ 515 nm and ${\lambda}-_{em}$ 553 nm, ${\mu}M$) + 0.035 ${\times}$ (TBARS level measured with a microplate reader at the absorbance wavelength 532 nm, ${\mu}M$). The estimated TBARS levels showed a better correlation with, and are closer to, the corresponding TBARS levels measured by HPLC compared to the values obtained by the microplate method. The TBARS estimation method reported here is simple and rapid, and that is generally in concordance with HPLC measurements. This method might be a useful tool for monitoring of urinary TBARS level in environmental epidemiologic surveys with large sample sizes.

Keywords

References

  1. Tatum, V.L., Changchit, C. and Chow, C.K. (1990) Measurement of malondialdehyde by high performance liquid chromatography with fluorescence detection. Lipids, 25, 226-229. https://doi.org/10.1007/BF02535752
  2. Nair, U., Bartsch, H. and Nair, J. (2007) Lipid peroxidationinduced DNA damage in cancer-prone inflammatory diseases: a review of published adduct types and levels in humans. Free Radical Biol. Med., 43, 1109-1120. https://doi.org/10.1016/j.freeradbiomed.2007.07.012
  3. Del Rio, D., Stewart, A.J. and Pellegrini, N. (2005) A review of recent studies on malondialdehyde as toxic molecule and biological marker of oxidative stress. Nutr. Metab. Cardiovasc. Dis., 15, 316-328. https://doi.org/10.1016/j.numecd.2005.05.003
  4. Lykkesfeldt, J. (2001) Determination of malondialdehyde as dithiobarbituric acid adduct in biological samples by HPLC with fluorescence detection: comparison with ultraviolet-visible spectrophotometry. Clin. Chem., 47, 1725-1727.
  5. Agarwal, R. and Chase, S.D. (2002) Rapid, fluorimetric-liquid chromatographic determination of malondialdehyde in biological samples. J. Chromatogr. B, Anal. Technol. Biomed. Life Sci., 775, 121-126. https://doi.org/10.1016/S1570-0232(02)00273-8
  6. Templar, J., Kon, S.P., Milligan, T.P., Newman, D.J. and Raftery, M.J. (1999) Increased plasma malondialdehyde levels in glomerular disease as determined by a fully validated HPLC method. Nephrol. Dial. Transplant., 14, 946-951. https://doi.org/10.1093/ndt/14.4.946
  7. Hendriks, T. and Assmann, R.F. (1990) Spectrophotometric correction for bile pigments in the thiobarbituric acid test for malondialdehyde-like substances in plasma. Med. Lab. Sci., 47, 10-16.
  8. Pyles, L.A., Stejskal, E.J. and Einzig, S. (1993) Spectrophotometric measurement of plasma 2-thiobarbituric acid-reactive substances in the presence of hemoglobin and bilirubin interference. Proc. Soc. Exp. Biol. Med., 202, 407-419. https://doi.org/10.3181/00379727-202-43552